{"id":"https://openalex.org/W2915633022","doi":"https://doi.org/10.5220/0007253400930100","title":"Measuring Upper-Extremity Use with One IMU","display_name":"Measuring Upper-Extremity Use with One IMU","publication_year":2019,"publication_date":"2019-01-01","ids":{"openalex":"https://openalex.org/W2915633022","doi":"https://doi.org/10.5220/0007253400930100","mag":"2915633022"},"language":"en","primary_location":{"id":"doi:10.5220/0007253400930100","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0007253400930100","pdf_url":null,"source":null,"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.5220/0007253400930100","any_repository_has_fulltext":null},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100459513","display_name":"Hang Wang","orcid":"https://orcid.org/0000-0002-6937-9958"},"institutions":[{"id":"https://openalex.org/I126520041","display_name":"University of Science and Technology of China","ror":"https://ror.org/04c4dkn09","country_code":"CN","type":"education","lineage":["https://openalex.org/I126520041","https://openalex.org/I19820366"]},{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["CN","NL"],"is_corresponding":true,"raw_author_name":"Hang Wang","raw_affiliation_strings":["University of Science and Technology of China, P. R. China, Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---","University of Science and Technology of China, P. R. China"],"affiliations":[{"raw_affiliation_string":"University of Science and Technology of China, P. R. China, Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---","institution_ids":["https://openalex.org/I94624287","https://openalex.org/I126520041"]},{"raw_affiliation_string":"University of Science and Technology of China, P. R. China","institution_ids":["https://openalex.org/I126520041"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102748727","display_name":"Mohamed Irfan Mohamed Refai","orcid":"https://orcid.org/0000-0002-3617-5131"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Mohamed Refai","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---"],"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5067633889","display_name":"Bert-Jan van Beijnum","orcid":"https://orcid.org/0000-0002-9673-752X"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Bert-Jan van Beijnum","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---"],"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, Enschede and The Netherlands, --- Select a Country ---","institution_ids":["https://openalex.org/I94624287"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100459513"],"corresponding_institution_ids":["https://openalex.org/I126520041","https://openalex.org/I94624287"],"apc_list":null,"apc_paid":null,"fwci":0.1661,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.54982818,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"93","last_page":"100"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10114","display_name":"Balance, Gait, and Falls Prevention","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/3612","display_name":"Physical Therapy, Sports Therapy and Rehabilitation"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10444","display_name":"Context-Aware Activity Recognition Systems","score":0.9674000144004822,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inertial-measurement-unit","display_name":"Inertial measurement unit","score":0.9197924137115479},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.8228764533996582},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.6518283486366272},{"id":"https://openalex.org/keywords/smoothness","display_name":"Smoothness","score":0.6483969688415527},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.576448380947113},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.5400508046150208},{"id":"https://openalex.org/keywords/protocol","display_name":"Protocol (science)","score":0.4863589406013489},{"id":"https://openalex.org/keywords/energy-expenditure","display_name":"Energy expenditure","score":0.41684022545814514},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3719710409641266},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.34555351734161377},{"id":"https://openalex.org/keywords/physical-medicine-and-rehabilitation","display_name":"Physical medicine and rehabilitation","score":0.32064178586006165},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3068884015083313},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20705625414848328},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.17783889174461365},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.17249584197998047},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.14460819959640503}],"concepts":[{"id":"https://openalex.org/C79061980","wikidata":"https://www.wikidata.org/wiki/Q941680","display_name":"Inertial measurement unit","level":2,"score":0.9197924137115479},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.8228764533996582},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.6518283486366272},{"id":"https://openalex.org/C102634674","wikidata":"https://www.wikidata.org/wiki/Q868473","display_name":"Smoothness","level":2,"score":0.6483969688415527},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.576448380947113},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.5400508046150208},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.4863589406013489},{"id":"https://openalex.org/C2988147884","wikidata":"https://www.wikidata.org/wiki/Q5377024","display_name":"Energy expenditure","level":2,"score":0.41684022545814514},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3719710409641266},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.34555351734161377},{"id":"https://openalex.org/C99508421","wikidata":"https://www.wikidata.org/wiki/Q2678675","display_name":"Physical medicine and rehabilitation","level":1,"score":0.32064178586006165},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3068884015083313},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20705625414848328},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.17783889174461365},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.17249584197998047},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.14460819959640503},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C134018914","wikidata":"https://www.wikidata.org/wiki/Q162606","display_name":"Endocrinology","level":1,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5220/0007253400930100","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0007253400930100","pdf_url":null,"source":null,"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies","raw_type":"proceedings-article"},{"id":"pmh:oai:ris.utwente.nl:openaire/7b2da309-d205-4716-bb17-54069eebc446","is_oa":false,"landing_page_url":"https://research.utwente.nl/en/publications/7b2da309-d205-4716-bb17-54069eebc446","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Wang, H, Mohamed Refai, M I & van Beijnum, B J F 2019, Measuring Upper-Extremity Use with One IMU. in BIOSIGNALS 2019 - 12th International Conference on Bio-Inspired Systems and Signal Processing, Proceedings; Part of 12th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2019. SCITEPRESS, pp. 93-100, 12th International Joint Conference on Biomedical Engineering Systems and Technologies 2019, Prague, Czech Republic, 22/02/19. https://doi.org/10.5220/0007253400930100","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"doi:10.5220/0007253400930100","is_oa":true,"landing_page_url":"https://doi.org/10.5220/0007253400930100","pdf_url":null,"source":null,"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies","raw_type":"proceedings-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G629491556","display_name":null,"funder_award_id":"(NWO)","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"},{"id":"https://openalex.org/G6877850787","display_name":null,"funder_award_id":"14905","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"}],"funders":[{"id":"https://openalex.org/F4320321015","display_name":"University of Twente","ror":"https://ror.org/006hf6230"},{"id":"https://openalex.org/F4320321800","display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","ror":"https://ror.org/04jsz6e67"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W78086009","https://openalex.org/W156628908","https://openalex.org/W1215311137","https://openalex.org/W1967571053","https://openalex.org/W1995912910","https://openalex.org/W1998033943","https://openalex.org/W2005110420","https://openalex.org/W2014857359","https://openalex.org/W2064278535","https://openalex.org/W2070805228","https://openalex.org/W2082956218","https://openalex.org/W2085126485","https://openalex.org/W2107555007","https://openalex.org/W2107795307","https://openalex.org/W2128123720","https://openalex.org/W2160146756","https://openalex.org/W2240092126","https://openalex.org/W2309803394","https://openalex.org/W2340924002","https://openalex.org/W2743678726"],"related_works":["https://openalex.org/W1967422967","https://openalex.org/W3120661687","https://openalex.org/W2029881158","https://openalex.org/W3196140453","https://openalex.org/W3044242125","https://openalex.org/W2037990170","https://openalex.org/W2768468910","https://openalex.org/W2999148748","https://openalex.org/W2978426962","https://openalex.org/W4206790194"],"abstract_inverted_index":{"Discharge":[0],"home":[1,38],"from":[2],"hospital":[3,30],"can":[4,119],"be":[5,32],"a":[6,50,60],"critical":[7],"stage":[8],"in":[9,28,129],"the":[10,29,37,43,79,82,93,101,115],"rehabilitation":[11],"of":[12,45,65,81],"patients":[13],"with":[14],"central":[15],"neurological":[16],"disorders":[17],"such":[18],"as":[19,92],"stroke.":[20],"The":[21,72,111],"new":[22,51],"skills":[23],"and":[24,48,78,121],"early":[25],"recovery":[26],"achieved":[27],"may":[31],"difficult":[33],"to":[34,36],"transfer":[35],"environment.":[39],"This":[40,84],"work":[41,85],"addresses":[42],"monitoring":[44],"arm":[46,124],"usage":[47,125],"proposed":[49,73],"metric":[52,74],"called":[53],"Weighted":[54],"Activity":[55],"Counts":[56],"(WAC)":[57],"based":[58],"on":[59],"sensing":[61],"system":[62],"that":[63],"consists":[64],"only":[66],"one":[67],"inertial":[68],"measurement":[69],"unit":[70],"(IMU).":[71],"combines":[75],"activity":[76],"counts":[77],"smoothness":[80],"movement.":[83],"defines":[86],"Normalized":[87],"Gross":[88],"Energy":[89],"Expenditure":[90],"(NGEC)":[91],"reference":[94],"metric.":[95],"WAC":[96],"shows":[97],"good":[98],"performance":[99],"under":[100],"validation":[102],"protocol":[103],"we":[104],"designed":[105],"(correlation":[106],"coefficient":[107],"r":[108],"&gt;":[109],"0:90).":[110],"optimal":[112],"placement":[113],"for":[114],"single":[116],"sensor":[117],"which":[118],"sufficiently":[120],"reliably":[122],"describe":[123],"is":[126],"also":[127],"explored":[128],"this":[130],"work.":[131]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-04-10T15:06:20.359241","created_date":"2025-10-10T00:00:00"}
