{"id":"https://openalex.org/W2374423601","doi":"https://doi.org/10.5220/0005906404540461","title":"Modelling and Simulation of the Temperature Control System in the Heating Installations from Nonresidential Buildings","display_name":"Modelling and Simulation of the Temperature Control System in the Heating Installations from Nonresidential Buildings","publication_year":2016,"publication_date":"2016-01-01","ids":{"openalex":"https://openalex.org/W2374423601","doi":"https://doi.org/10.5220/0005906404540461","mag":"2374423601"},"language":"en","primary_location":{"id":"doi:10.5220/0005906404540461","is_oa":false,"landing_page_url":"https://doi.org/10.5220/0005906404540461","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Conference on Smart Cities and Green ICT Systems","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111565931","display_name":"Daniel Popescu","orcid":null},"institutions":[{"id":"https://openalex.org/I148178115","display_name":"Technical University of Civil Engineering of Bucharest","ror":"https://ror.org/03d187f57","country_code":"RO","type":"education","lineage":["https://openalex.org/I148178115"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Daniel Popescu","raw_affiliation_strings":["Technical University of Civil Engineering, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technical University of Civil Engineering, Romania","institution_ids":["https://openalex.org/I148178115"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077012704","display_name":"Ioan Borza","orcid":null},"institutions":[{"id":"https://openalex.org/I148178115","display_name":"Technical University of Civil Engineering of Bucharest","ror":"https://ror.org/03d187f57","country_code":"RO","type":"education","lineage":["https://openalex.org/I148178115"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Ioan Borza","raw_affiliation_strings":["Department of Civil Engineering and Building Services, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Civil Engineering and Building Services, Romania","institution_ids":["https://openalex.org/I148178115"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.04424076,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"454","last_page":"461"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9855999946594238,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9855999946594238,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heating-system","display_name":"Heating system","score":0.6822446584701538},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.6308201551437378},{"id":"https://openalex.org/keywords/building-envelope","display_name":"Building envelope","score":0.6267784833908081},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.6130259037017822},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.539894700050354},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5196365118026733},{"id":"https://openalex.org/keywords/automatic-control","display_name":"Automatic control","score":0.5144546031951904},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.506782591342926},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.46355098485946655},{"id":"https://openalex.org/keywords/envelope","display_name":"Envelope (radar)","score":0.4610987901687622},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4603222906589508},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.4477173089981079},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.44387465715408325},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3533260226249695},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34382396936416626},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3184415102005005},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2910389304161072},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.22879868745803833},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.06948307156562805}],"concepts":[{"id":"https://openalex.org/C2777154459","wikidata":"https://www.wikidata.org/wiki/Q2429341","display_name":"Heating system","level":2,"score":0.6822446584701538},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6308201551437378},{"id":"https://openalex.org/C196803488","wikidata":"https://www.wikidata.org/wiki/Q4986592","display_name":"Building envelope","level":3,"score":0.6267784833908081},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.6130259037017822},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.539894700050354},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5196365118026733},{"id":"https://openalex.org/C167123822","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automatic control","level":2,"score":0.5144546031951904},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.506782591342926},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.46355098485946655},{"id":"https://openalex.org/C65155139","wikidata":"https://www.wikidata.org/wiki/Q5380912","display_name":"Envelope (radar)","level":3,"score":0.4610987901687622},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4603222906589508},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4477173089981079},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.44387465715408325},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3533260226249695},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34382396936416626},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3184415102005005},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2910389304161072},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.22879868745803833},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06948307156562805},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.5220/0005906404540461","is_oa":false,"landing_page_url":"https://doi.org/10.5220/0005906404540461","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Conference on Smart Cities and Green ICT Systems","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9100000262260437}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2377022227","https://openalex.org/W2358731986","https://openalex.org/W99300660","https://openalex.org/W4200325458","https://openalex.org/W2353362866","https://openalex.org/W2087915021","https://openalex.org/W3205967655","https://openalex.org/W2364340626","https://openalex.org/W2388380443","https://openalex.org/W2142312987"],"abstract_inverted_index":{"The":[0,23,46,54,110,141],"article":[1],"addresses":[2],"specific":[3],"issues":[4],"of":[5,51,64,80,102,112,132,137,143,157],"the":[6,29,33,39,43,62,65,73,78,81,87,91,97,100,103,108,113,117,133,138,144,150,161,167],"automated":[7],"heating":[8,66,104,135],"systems":[9],"for":[10,56,72,90,170],"non-residential":[11],"buildings,":[12],"which":[13],"aim":[14],"to":[15,99],"ensure":[16],"thermal":[17,74],"comfort":[18],"with":[19,129,155],"low":[20],"energy":[21],"consumption.":[22],"specialized":[24,47,82],"automatic":[25,48,83,114,134,163],"system":[26,49,84,136],"maintains":[27],"constant":[28],"indoor":[30],"temperature":[31,105],"when":[32],"heat":[34,40],"input":[35],"in":[36,107,124,160,166],"building":[37,44,168],"equals":[38],"loss":[41],"through":[42],"envelope.":[45],"consists":[50],"several":[52],"subsystems.":[53],"model":[55,145],"each":[57],"subsystem":[58],"is":[59,85,146],"obtained":[60,86,152],"considering":[61],"particularities":[63],"processes":[67],"from":[68],"buildings":[69],"and":[70,116],"requirements":[71],"comfort.":[75],"By":[76],"simulating":[77],"operation":[79,111],"time":[88,127],"behavior":[89],"main":[92],"physical":[93],"values":[94],"that":[95],"characterizes":[96],"system,_relevant":[98],"quality":[101],"control":[106,118],"building.":[109,140],"controller":[115],"valve":[119],"are":[120],"analyzed":[121],"by":[122,148,153],"simulation,":[123],"a":[125],"comparable":[126],"interval":[128],"transient":[130],"regime":[131],"real":[139,162],"validation":[142],"done":[147],"comparing":[149],"results":[151,156],"simulation":[154],"experimental":[158],"measurements":[159],"system,":[164],"implemented":[165],"chosen":[169],"study.":[171]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
