{"id":"https://openalex.org/W7169781125","doi":"https://doi.org/10.48550/arxiv.2607.15705","title":"A Benchmark for Electrical Load Forecasting Across Grid Levels: Time-Series Transformers Outperform Established Methods","display_name":"A Benchmark for Electrical Load Forecasting Across Grid Levels: Time-Series Transformers Outperform Established Methods","publication_year":2026,"publication_date":"2026-07-17","ids":{"openalex":"https://openalex.org/W7169781125","doi":"https://doi.org/10.48550/arxiv.2607.15705"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2607.15705","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2607.15705","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2607.15705","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070592781","display_name":"Matthias Hertel","orcid":"https://orcid.org/0000-0002-0814-766X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hertel, Matthias","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5141181000","display_name":"Sebastian P\u00fctz","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"P\u00fctz, Sebastian","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5118214097","display_name":"Jonathan Kolar","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kolar, Jonathan","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5141181845","display_name":"Benjamin Sch\u00e4fer","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sch\u00e4fer, Benjamin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5141220520","display_name":"Ralf Mikut","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mikut, Ralf","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5141185565","display_name":"Veit Hagenmeyer","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hagenmeyer, Veit","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9520999789237976,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9520999789237976,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11344","display_name":"Traffic Prediction and Management Techniques","score":0.008200000040233135,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.007400000002235174,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5921000242233276},{"id":"https://openalex.org/keywords/benchmark","display_name":"Benchmark (surveying)","score":0.5497999787330627},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5307999849319458},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5117999911308289},{"id":"https://openalex.org/keywords/electrical-load","display_name":"Electrical load","score":0.44929999113082886},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.39579999446868896},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.3935999870300293},{"id":"https://openalex.org/keywords/demand-forecasting","display_name":"Demand forecasting","score":0.38350000977516174}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6801000237464905},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5921000242233276},{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.5497999787330627},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5307999849319458},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5117999911308289},{"id":"https://openalex.org/C77715397","wikidata":"https://www.wikidata.org/wiki/Q931447","display_name":"Electrical load","level":3,"score":0.44929999113082886},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.39579999446868896},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.3935999870300293},{"id":"https://openalex.org/C193809577","wikidata":"https://www.wikidata.org/wiki/Q3409300","display_name":"Demand forecasting","level":2,"score":0.38350000977516174},{"id":"https://openalex.org/C8642999","wikidata":"https://www.wikidata.org/wiki/Q4171168","display_name":"Hyperparameter","level":2,"score":0.382099986076355},{"id":"https://openalex.org/C2778712577","wikidata":"https://www.wikidata.org/wiki/Q3505966","display_name":"Retraining","level":2,"score":0.3675999939441681},{"id":"https://openalex.org/C2777908891","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Load profile","level":3,"score":0.3612000048160553},{"id":"https://openalex.org/C86251818","wikidata":"https://www.wikidata.org/wiki/Q816754","display_name":"Benchmarking","level":2,"score":0.3573000133037567},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.32989999651908875},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.30790001153945923},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.3068999946117401},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.29750001430511475},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.2930000126361847},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.29120001196861267},{"id":"https://openalex.org/C175291020","wikidata":"https://www.wikidata.org/wiki/Q1156822","display_name":"Offset (computer science)","level":2,"score":0.28619998693466187},{"id":"https://openalex.org/C115051666","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Ranging","level":2,"score":0.27480000257492065},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.26600000262260437},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2524999976158142}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2607.15705","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2607.15705","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2607.15705","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2607.15705","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"score":0.852379560470581,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Accurate":[0],"load":[1,43,72,132],"forecasting":[2,44,73,192],"at":[3],"multiple":[4],"grid":[5,46,60],"levels":[6],"is":[7,110],"essential":[8],"for":[9,19,30,42,70,130],"future":[10],"smart":[11],"grids,":[12],"ranging":[13],"from":[14,106],"aggregated":[15],"control":[16,57],"area":[17],"forecasts":[18,25],"balancing":[20],"supply":[21],"and":[22,33,62,74,109,167,169,180],"demand":[23],"to":[24,153],"of":[26,93,175],"individual":[27,63],"end-consumer":[28],"loads":[29],"demand-side":[31],"management":[32,35],"energy":[34],"systems.":[36],"We":[37,66,134],"present":[38],"a":[39,53,99],"comprehensive":[40],"benchmark":[41],"across":[45],"levels,":[47],"comprising":[48],"three":[49],"datasets":[50,150],"that":[51,76,103,123,185],"represent":[52],"transmission":[54],"system":[55],"operator":[56],"area,":[58],"low-voltage":[59],"feeders,":[61],"end":[64],"consumers.":[65],"evaluate":[67,136],"ten":[68],"methods":[69],"short-term":[71],"find":[75],"Transformer-based":[77,138],"approaches":[78],"consistently":[79],"outperform":[80],"established":[81],"methods,":[82],"reducing":[83],"forecast":[84],"error":[85],"by":[86],"6.6-10.7":[87],"%.":[88],"To":[89],"analyze":[90],"the":[91,116,137,159,173,190],"impact":[92],"architectural":[94,125],"design,":[95],"we":[96],"introduce":[97],"YAformer,":[98],"flexible":[100],"Transformer":[101,118],"architecture":[102],"integrates":[104],"modifications":[105,126],"prior":[107],"work":[108],"optimized":[111],"via":[112],"hyperparameter":[113],"optimization.":[114],"However,":[115],"standard":[117],"achieves":[119],"superior":[120],"performance,":[121],"suggesting":[122],"these":[124],"are":[127,186],"not":[128],"required":[129],"accurate":[131],"forecasting.":[133],"further":[135],"time-series":[139,191],"foundation":[140],"model":[141],"Chronos-2,":[142],"which":[143],"demonstrates":[144],"competitive":[145],"zero-shot":[146],"performance":[147],"on":[148],"two":[149],"but":[151],"fails":[152],"accurately":[154],"capture":[155],"special":[156],"events":[157],"in":[158,189],"TSO":[160],"data.":[161],"Detailed":[162],"analyses":[163],"reveal":[164],"model-specific":[165],"strengths":[166],"weaknesses,":[168],"ablation":[170],"studies":[171],"highlight":[172],"importance":[174],"long":[176],"input":[177],"contexts,":[178],"covariates":[179],"continuous":[181],"retraining":[182],"-":[183],"aspects":[184],"often":[187],"overlooked":[188],"literature.":[193]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2026-07-21T00:00:00"}
