{"id":"https://openalex.org/W7165623445","doi":"https://doi.org/10.48550/arxiv.2606.23586","title":"Two-Stage Optimization for Dynamic Line Rating and Energy Storage Deployment","display_name":"Two-Stage Optimization for Dynamic Line Rating and Energy Storage Deployment","publication_year":2026,"publication_date":"2026-06-22","ids":{"openalex":"https://openalex.org/W7165623445","doi":"https://doi.org/10.48550/arxiv.2606.23586"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2606.23586","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.23586","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2606.23586","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075269645","display_name":"Abanish Tiwari","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tiwari, Abanish","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083762087","display_name":"Phurba T Sherpa","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sherpa, Phurba T.","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5138640331","display_name":"Chandan Chaudhary","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chaudhary, Chandan","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5133076155","display_name":"Mohammed Ben-Idris","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ben-Idris, Mohammed","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5139142323","display_name":"Joydeep Mitra","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mitra, Joydeep","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.0031999999191612005,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.47040000557899475},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4681999981403351},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.42910000681877136},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.4180000126361847},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.41350001096725464},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.38519999384880066},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.3774999976158142},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.3732999861240387},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.36090001463890076}],"concepts":[{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.47040000557899475},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4681999981403351},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4388999938964844},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.438400000333786},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.42910000681877136},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.4180000126361847},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.41350001096725464},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.397599995136261},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3937999904155731},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.38519999384880066},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3797999918460846},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.3774999976158142},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.3732999861240387},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.36090001463890076},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.35569998621940613},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.34630000591278076},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.3165000081062317},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.3156999945640564},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.31279999017715454},{"id":"https://openalex.org/C187633118","wikidata":"https://www.wikidata.org/wiki/Q1317949","display_name":"Economic dispatch","level":4,"score":0.30140000581741333},{"id":"https://openalex.org/C183287310","wikidata":"https://www.wikidata.org/wiki/Q2142963","display_name":"Thermal energy storage","level":2,"score":0.2994999885559082},{"id":"https://openalex.org/C41045048","wikidata":"https://www.wikidata.org/wiki/Q202843","display_name":"Linear programming","level":2,"score":0.29510000348091125},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2906999886035919},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.28850001096725464},{"id":"https://openalex.org/C2781007418","wikidata":"https://www.wikidata.org/wiki/Q1456934","display_name":"Capacity planning","level":2,"score":0.2867000102996826},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.2849999964237213},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.2671999931335449},{"id":"https://openalex.org/C116219307","wikidata":"https://www.wikidata.org/wiki/Q7236625","display_name":"Power system simulation","level":4,"score":0.26170000433921814},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.2572999894618988},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.2526000142097473}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2606.23586","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.23586","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2606.23586","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.23586","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.587232768535614,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,171],"increasing":[1],"penetration":[2],"of":[3,25,96],"distributed":[4],"energy":[5,35,101,142],"resources":[6],"(DER)":[7],"and":[8,14,34,49,65,84,99,114,123,131,144,160,187,195],"weather-driven":[9],"variability":[10],"has":[11],"intensified":[12],"congestion":[13],"reliability":[15],"stress":[16],"in":[17],"transmission":[18,191],"networks.":[19],"Strategies":[20],"that":[21,184],"enhance":[22],"the":[23,104,135,138,177],"utilization":[24],"existing":[26],"infrastructure,":[27],"such":[28],"as":[29],"static":[30],"line":[31,56,149],"ratings":[32,57],"(SLR)":[33],"storage":[36,71],"systems":[37,72],"(ESS),":[38],"have":[39],"therefore":[40],"become":[41],"necessary.":[42],"SLRs":[43],"rely":[44],"on":[45,81,176],"conservative":[46],"ambient":[47],"assumptions":[48],"often":[50],"understate":[51],"thermal":[52],"limits,":[53],"whereas":[54],"dynamic":[55],"(DLR)":[58],"adjust":[59],"capacity":[60,143],"according":[61],"to":[62,127,156,167],"weather":[63,152,200],"conditions":[64],"unlock":[66],"additional":[67],"transfer":[68],"capability.":[69],"Energy":[70],"provide":[73],"temporal":[74],"flexibility,":[75],"but":[76],"their":[77],"transmission-level":[78],"effectiveness":[79],"depends":[80],"proper":[82],"siting":[83],"sizing.":[85],"This":[86],"paper":[87],"proposes":[88],"a":[89,107],"two-stage":[90],"optimization":[91],"method":[92],"for":[93],"joint":[94],"placement":[95],"DLR":[97,112,158,186],"installations":[98],"utility-scale":[100],"storage.":[102],"In":[103,134],"first":[105],"stage,":[106,137],"mixed-integer":[108],"linear":[109],"program":[110],"selects":[111],"corridors":[113],"ESS":[115,141,188],"buses":[116],"by":[117],"minimizing":[118],"operating":[119,145],"cost,":[120],"DER":[121],"curtailment,":[122],"load-shedding":[124],"penalties":[125],"subject":[126],"DC":[128],"power":[129],"flow":[130],"investment":[132],"constraints.":[133],"second":[136],"model":[139],"determines":[140],"schedules":[146],"under":[147,199],"ambient-driven":[148],"ratings.":[150],"Ambient":[151],"data":[153],"is":[154,165],"used":[155],"generate":[157],"profiles,":[159],"sequential":[161],"Monte":[162],"Carlo":[163],"simulation":[164],"applied":[166],"assess":[168],"system":[169,197],"adequacy.":[170],"proposed":[172],"method,":[173],"when":[174],"deployed":[175],"modified":[178],"IEEE":[179],"RTS":[180],"24-bus":[181],"system,":[182],"shows":[183],"coordinated":[185],"planning":[189],"improves":[190],"capability,":[192],"mitigates":[193],"congestion,":[194],"strengthens":[196],"adequacy":[198],"variability.":[201]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2026-06-24T00:00:00"}