{"id":"https://openalex.org/W7164810810","doi":"https://doi.org/10.48550/arxiv.2606.13853","title":"Spatial Load Correlation in AI Data-Center-Dominated Power Systems","display_name":"Spatial Load Correlation in AI Data-Center-Dominated Power Systems","publication_year":2026,"publication_date":"2026-06-11","ids":{"openalex":"https://openalex.org/W7164810810","doi":"https://doi.org/10.48550/arxiv.2606.13853"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2606.13853","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.13853","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2606.13853","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5138640331","display_name":"Chandan Chaudhary","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chaudhary, Chandan","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113892423","display_name":"Alaaeldein Abdelkader","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Abdelkader, Alaaeldein","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5138649718","display_name":"Yansong Pei","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pei, Yansong","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5138271990","display_name":"Mohammed Benidris","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Benidris, Mohammed","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5138635378","display_name":"Joydeep Mitra","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mitra, Joydeep","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.5760999917984009,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.5760999917984009,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.1324000060558319,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.10639999806880951,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6635000109672546},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.6463000178337097},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.558899998664856},{"id":"https://openalex.org/keywords/independence","display_name":"Independence (probability theory)","score":0.4997999966144562},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.43369999527931213},{"id":"https://openalex.org/keywords/margin","display_name":"Margin (machine learning)","score":0.4271000027656555},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.41850000619888306},{"id":"https://openalex.org/keywords/correlation","display_name":"Correlation","score":0.41749998927116394},{"id":"https://openalex.org/keywords/load-shedding","display_name":"Load Shedding","score":0.4072999954223633}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6635000109672546},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.6463000178337097},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.558899998664856},{"id":"https://openalex.org/C35651441","wikidata":"https://www.wikidata.org/wiki/Q625303","display_name":"Independence (probability theory)","level":2,"score":0.4997999966144562},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.43369999527931213},{"id":"https://openalex.org/C774472","wikidata":"https://www.wikidata.org/wiki/Q6760393","display_name":"Margin (machine learning)","level":2,"score":0.4271000027656555},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.41850000619888306},{"id":"https://openalex.org/C117220453","wikidata":"https://www.wikidata.org/wiki/Q5172842","display_name":"Correlation","level":2,"score":0.41749998927116394},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4174000024795532},{"id":"https://openalex.org/C2779777743","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Load Shedding","level":4,"score":0.4072999954223633},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3716000020503998},{"id":"https://openalex.org/C4679612","wikidata":"https://www.wikidata.org/wiki/Q866298","display_name":"Aggregate (composite)","level":2,"score":0.3635999858379364},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3555999994277954},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.3449000120162964},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.3280999958515167},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.320499986410141},{"id":"https://openalex.org/C12713177","wikidata":"https://www.wikidata.org/wiki/Q1900281","display_name":"Perspective (graphical)","level":2,"score":0.3156000077724457},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3077000081539154},{"id":"https://openalex.org/C2777908891","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Load profile","level":3,"score":0.3066999912261963},{"id":"https://openalex.org/C150060386","wikidata":"https://www.wikidata.org/wiki/Q7574054","display_name":"Spatial correlation","level":2,"score":0.3052999973297119},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.29989999532699585},{"id":"https://openalex.org/C168110828","wikidata":"https://www.wikidata.org/wiki/Q1331626","display_name":"Spectral density","level":2,"score":0.27730000019073486},{"id":"https://openalex.org/C2781316041","wikidata":"https://www.wikidata.org/wiki/Q1230584","display_name":"Diversity (politics)","level":2,"score":0.27390000224113464},{"id":"https://openalex.org/C78736273","wikidata":"https://www.wikidata.org/wiki/Q946764","display_name":"Natural frequency","level":3,"score":0.273499995470047},{"id":"https://openalex.org/C75778745","wikidata":"https://www.wikidata.org/wiki/Q342626","display_name":"Lag","level":2,"score":0.2721000015735626},{"id":"https://openalex.org/C2776502983","wikidata":"https://www.wikidata.org/wiki/Q690182","display_name":"Contrast (vision)","level":2,"score":0.258899986743927}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2606.13853","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.13853","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2606.13853","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2606.13853","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"score":0.5397286415100098,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,96],"proliferation":[1],"of":[2,16,19,30,68],"large-scale":[3],"data":[4,84],"centers":[5,85],"introduces":[6],"spatially":[7],"correlated":[8,45],"demand":[9],"profiles":[10],"that":[11,44,78],"challenge":[12],"the":[13,28],"long-standing":[14],"assumption":[15],"statistical":[17],"independence":[18],"loads":[20],"in":[21,82,116],"power":[22,59],"system":[23,100],"analysis.":[24],"This":[25],"paper":[26],"examines":[27],"emergence":[29],"such":[31],"load":[32,46,70],"correlations":[33],"and":[34,61,90,110],"evaluates":[35],"their":[36],"impact":[37],"on":[38],"data-center-dominated":[39],"grids.":[40],"Analytical":[41],"derivations":[42],"reveal":[43],"fluctuations":[47,92],"amplify":[48],"aggregate":[49],"stochastic":[50],"disturbances,":[51],"reduce":[52],"voltage":[53,91],"stability":[54,64,112],"margins":[55],"through":[56],"weakened":[57],"reactive":[58],"stiffness,":[60],"degrade":[62],"frequency":[63,88],"margin":[65],"by":[66],"erosion":[67],"natural":[69],"diversity":[71,123],"effects.":[72],"Real-time":[73],"digital":[74],"simulation":[75],"studies":[76],"confirm":[77],"moderate":[79],"spatial":[80],"correlation":[81],"distributed":[83],"produces":[86],"simultaneous":[87],"deviations":[89],"across":[93],"multiple":[94],"buses.":[95],"findings":[97],"offer":[98],"transmission":[99],"operators":[101],"a":[102],"physics-based":[103],"perspective":[104],"to":[105],"interpret":[106],"emerging":[107],"oscillatory":[108],"phenomena":[109],"establish":[111],"planning":[113],"criteria":[114],"grounded":[115],"measurable":[117],"load-correlation":[118],"structures":[119],"rather":[120],"than":[121],"traditional":[122],"assumptions.":[124]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2026-06-16T00:00:00"}