{"id":"https://openalex.org/W7162471687","doi":"https://doi.org/10.48550/arxiv.2605.24406","title":"A Unified Python Framework for Direct PPO-based Control of AHUs with Economizer Logic and CO2-Constrained Ventilation","display_name":"A Unified Python Framework for Direct PPO-based Control of AHUs with Economizer Logic and CO2-Constrained Ventilation","publication_year":2026,"publication_date":"2026-05-23","ids":{"openalex":"https://openalex.org/W7162471687","doi":"https://doi.org/10.48550/arxiv.2605.24406"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2605.24406","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.24406","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2605.24406","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5137083690","display_name":"Erfan Haghighat Damavandi","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Damavandi, Erfan Haghighat","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089215734","display_name":"Davide Papurello","orcid":"https://orcid.org/0000-0003-1455-8964"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Papurello, Davide","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5137051623","display_name":"Mahdi Alibeigi","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Alibeigi, Mahdi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5137037032","display_name":"Armin Keshavarz","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Keshavarz, Armin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5137027104","display_name":"Simone Canevarolo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Canevarolo, Simone","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5137023768","display_name":"Marco Condo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Condo, Marco","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5638999938964844,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.5638999938964844,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.19259999692440033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.019099999219179153,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.7910000085830688},{"id":"https://openalex.org/keywords/economizer","display_name":"Economizer","score":0.7759000062942505},{"id":"https://openalex.org/keywords/python","display_name":"Python (programming language)","score":0.6261000037193298},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.48159998655319214},{"id":"https://openalex.org/keywords/flight-envelope","display_name":"Flight envelope","score":0.4528999924659729},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"Indoor air quality","score":0.4320000112056732},{"id":"https://openalex.org/keywords/building-envelope","display_name":"Building envelope","score":0.4180000126361847},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.4066999852657318},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.39079999923706055}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.7910000085830688},{"id":"https://openalex.org/C41004858","wikidata":"https://www.wikidata.org/wiki/Q1389702","display_name":"Economizer","level":3,"score":0.7759000062942505},{"id":"https://openalex.org/C519991488","wikidata":"https://www.wikidata.org/wiki/Q28865","display_name":"Python (programming language)","level":2,"score":0.6261000037193298},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5234000086784363},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4918999969959259},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.48159998655319214},{"id":"https://openalex.org/C72898154","wikidata":"https://www.wikidata.org/wiki/Q458038","display_name":"Flight envelope","level":3,"score":0.4528999924659729},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.4320000112056732},{"id":"https://openalex.org/C196803488","wikidata":"https://www.wikidata.org/wiki/Q4986592","display_name":"Building envelope","level":3,"score":0.4180000126361847},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4171999990940094},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.4066999852657318},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.39079999923706055},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3488999903202057},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.336899995803833},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.336899995803833},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.3352999985218048},{"id":"https://openalex.org/C43521106","wikidata":"https://www.wikidata.org/wiki/Q2165493","display_name":"Pipeline (software)","level":2,"score":0.329800009727478},{"id":"https://openalex.org/C2777655017","wikidata":"https://www.wikidata.org/wiki/Q1501161","display_name":"Toolbox","level":2,"score":0.32600000500679016},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.3102000057697296},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3098999857902527},{"id":"https://openalex.org/C34413123","wikidata":"https://www.wikidata.org/wiki/Q170978","display_name":"Robotics","level":3,"score":0.30730000138282776},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.28600001335144043},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.2800000011920929},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2766000032424927},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.27230000495910645},{"id":"https://openalex.org/C51176869","wikidata":"https://www.wikidata.org/wiki/Q7915706","display_name":"Variable air volume","level":3,"score":0.2687000036239624},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.2581999897956848},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.257099986076355},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.2535000145435333}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2605.24406","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.24406","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2605.24406","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.24406","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8856209516525269,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Optimizing":[0],"HVAC":[1,26,56],"(Heating,":[2],"Ventilation":[3],"and":[4,67,91,184,196],"Air":[5],"Conditioning)":[6],"can":[7],"enhance":[8],"a":[9,37,51,76,85,114,177],"building's":[10],"energy":[11,185,204],"efficiency":[12,186],"while":[13],"providing":[14],"comfort":[15],"levels":[16],"for":[17,194],"its":[18],"occupants.":[19],"Using":[20],"conventional":[21],"control":[22],"systems":[23,57],"to":[24,54,99,122,142,153,167,199],"maintain":[25],"functions":[27],"is":[28,113,129,151],"often":[29],"difficult":[30],"because":[31],"of":[32,36,61,97,110,136,209],"the":[33,59,68,101,120,133,137,158,207],"nonlinear":[34],"characteristics":[35],"building":[38,203],"envelope":[39],"as":[40],"it":[41],"experiences":[42],"stochastic":[43],"load":[44],"variations":[45],"over":[46],"time.":[47],"This":[48],"paper":[49],"presents":[50],"new":[52],"approach":[53],"optimizing":[55],"through":[58],"use":[60],"Deep":[62],"Reinforcement":[63],"Learning":[64],"(DRL)":[65],"algorithms":[66],"Proximal":[69],"Policy":[70],"Optimization":[71],"(PPO)":[72],"algorithm":[73],"implemented":[74],"in":[75],"custom":[77],"Python":[78],"performance":[79],"environment.":[80,160],"The":[81,161],"DRL":[82],"system":[83],"uses":[84],"second":[86],"order":[87],"resistor-capacitor":[88],"thermal":[89],"model":[90],"an":[92,148,192],"integrated":[93],"dynamic":[94],"mass":[95],"balance":[96],"CO2":[98,141],"replicate":[100],"complex":[102],"physics":[103],"associated":[104],"with":[105],"buildings.":[106],"One":[107],"major":[108],"innovation":[109],"this":[111],"study":[112],"\"Hierarchical":[115],"Flow":[116],"Logic,\"":[117],"which":[118],"provides":[119,191],"means":[121],"ensure":[123],"that":[124,139,165],"indoor":[125],"air":[126],"quality":[127],"(IAQ)":[128],"maintained":[130],"by":[131,171],"overriding":[132],"accepted":[134],"actions":[135],"agent":[138,179],"cause":[140],"exceed":[143],"1000":[144],"ppm.":[145],"In":[146],"addition,":[147],"enthalpy-based":[149],"economiser":[150],"used":[152],"create":[154],"free":[155],"cooling":[156],"from":[157],"outdoor":[159],"experimental":[162],"data":[163],"shows":[164],"compared":[166],"PID":[168],"controllers":[169],"tuned":[170],"GA":[172],"or":[173],"traditional":[174],"On-Off":[175],"controls,":[176],"PPO":[178],"has":[180],"better":[181],"temperature":[182],"stability":[183],"overall.":[187],"An":[188],"end-to-end":[189],"pipeline":[190],"avenue":[193],"robust":[195],"generalized":[197],"solutions":[198],"help":[200],"implement":[201],"smart":[202],"management":[205],"within":[206],"context":[208],"real":[210],"hardware":[211],"implementation.":[212]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2026-05-27T00:00:00"}
