{"id":"https://openalex.org/W7161287273","doi":"https://doi.org/10.48550/arxiv.2605.14509","title":"Admittance-Guided Inverter Dispatch Command Manipulation Attack: A Grid Stability-Oriented Approach","display_name":"Admittance-Guided Inverter Dispatch Command Manipulation Attack: A Grid Stability-Oriented Approach","publication_year":2026,"publication_date":"2026-05-14","ids":{"openalex":"https://openalex.org/W7161287273","doi":"https://doi.org/10.48550/arxiv.2605.14509"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2605.14509","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.14509","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2605.14509","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5136207330","display_name":"Hongwei Zhen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhen, Hongwei","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101954504","display_name":"Ze Yu","orcid":"https://orcid.org/0000-0002-5743-6978"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yu, Ze","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5136271809","display_name":"Xin Xiang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xiang, Xin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5136247813","display_name":"Mingyang Sun","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sun, Mingyang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5136250403","display_name":"Wuhua Li","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li, Wuhua","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.45989999175071716,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.45989999175071716,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.3330000042915344,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.05920000001788139,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.6279000043869019},{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.6065000295639038},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.5568000078201294},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5512999892234802},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.49320000410079956},{"id":"https://openalex.org/keywords/economic-dispatch","display_name":"Economic dispatch","score":0.48660001158714294},{"id":"https://openalex.org/keywords/admittance","display_name":"Admittance","score":0.4819999933242798},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.4796000123023987},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.4666000008583069}],"concepts":[{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.6279000043869019},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.6065000295639038},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.5568000078201294},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5512999892234802},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5145999789237976},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.49320000410079956},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.48739999532699585},{"id":"https://openalex.org/C187633118","wikidata":"https://www.wikidata.org/wiki/Q1317949","display_name":"Economic dispatch","level":4,"score":0.48660001158714294},{"id":"https://openalex.org/C108811297","wikidata":"https://www.wikidata.org/wiki/Q214518","display_name":"Admittance","level":3,"score":0.4819999933242798},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4796000123023987},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.4666000008583069},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4569000005722046},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4066999852657318},{"id":"https://openalex.org/C151201525","wikidata":"https://www.wikidata.org/wiki/Q177239","display_name":"Limit (mathematics)","level":2,"score":0.40549999475479126},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3752000033855438},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.3544999957084656},{"id":"https://openalex.org/C127934551","wikidata":"https://www.wikidata.org/wiki/Q1148098","display_name":"Harmonic","level":2,"score":0.320499986410141},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.31459999084472656},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.31209999322891235},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3100000023841858},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3070000112056732},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.27790001034736633},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.2718000113964081},{"id":"https://openalex.org/C133833761","wikidata":"https://www.wikidata.org/wiki/Q16001847","display_name":"Admittance parameters","level":3,"score":0.2671999931335449},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.25690001249313354},{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.25519999861717224}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2605.14509","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.14509","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2605.14509","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2605.14509","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0],"high":[1],"penetration":[2],"of":[3,26,105],"voltage":[4],"source":[5],"converters":[6],"in":[7],"modern":[8],"smart":[9],"microgrids":[10],"enhances":[11],"operational":[12],"flexibility":[13],"while":[14,155],"introducing":[15],"complex":[16],"cyber-physical":[17],"vulnerabilities.":[18],"Existing":[19],"cyber-attack":[20],"studies":[21],"either":[22],"require":[23],"detailed":[24],"knowledge":[25],"system":[27,76,150],"topology":[28],"and":[29,57,67,92,129],"controller":[30],"dynamics":[31],"or":[32,46],"depend":[33],"on":[34,114,138],"repeated":[35],"online":[36],"interactions,":[37],"which":[38],"may":[39],"compromise":[40],"practicality":[41],"by":[42],"generating":[43],"operationally":[44],"infeasible":[45],"limit-violating":[47],"commands.":[48],"This":[49],"article":[50],"investigates":[51],"a":[52,93,118,139],"dispatch":[53,70,111,133,159],"command":[54,71,146,166],"manipulation":[55],"attack":[56],"develops":[58],"an":[59],"admittance-guided":[60],"framework":[61],"to":[62,83,100,123],"identify":[63],"the":[64,68,102,109,115,125,130,144,149,162],"vulnerable":[65,127],"inverter":[66,80,128],"worst-case":[69,132],"that":[72,143],"most":[73,126],"severely":[74],"degrades":[75],"stability.":[77],"A":[78],"compromised":[79],"is":[81,97,121],"utilized":[82],"inject":[84],"controlled":[85],"harmonic":[86],"perturbations":[87],"for":[88,164],"sparse":[89],"admittance":[90,104],"measurement,":[91],"physics-informed":[94],"neural":[95],"network":[96],"then":[98],"employed":[99],"reconstruct":[101],"operating-point-dependent":[103],"target":[106],"inverters":[107],"over":[108],"feasible":[110],"region.":[112],"Based":[113],"reconstructed":[116],"admittance,":[117],"stability-margin-oriented":[119],"optimization":[120],"formulated":[122],"locate":[124],"corresponding":[131],"command.":[134],"Controller":[135],"hardware-in-the-loop":[136],"experiments":[137],"five-inverter":[140],"microgrid":[141],"demonstrate":[142],"identified":[145],"can":[147],"drive":[148],"into":[151],"severe":[152],"sub-synchronous":[153],"oscillations":[154],"remaining":[156],"within":[157],"nominal":[158],"bounds,":[160],"highlighting":[161],"need":[163],"stability-aware":[165],"screening":[167],"beyond":[168],"static":[169],"limit":[170],"checking.":[171]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2026-05-16T00:00:00"}