{"id":"https://openalex.org/W7154575423","doi":"https://doi.org/10.48550/arxiv.2604.13926","title":"Importance of Aggregated DER Installed Capacity in Distribution Networks","display_name":"Importance of Aggregated DER Installed Capacity in Distribution Networks","publication_year":2026,"publication_date":"2026-04-15","ids":{"openalex":"https://openalex.org/W7154575423","doi":"https://doi.org/10.48550/arxiv.2604.13926"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2604.13926","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.13926","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2604.13926","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102927822","display_name":"Alexandre Gouveia","orcid":"https://orcid.org/0000-0001-7023-3254"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Gouveia, Alexandre M. V.","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5133767164","display_name":"Md. Umar Hashmi","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hashmi, Md. Umar","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5133818833","display_name":"Reinhilde D'hulst","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"D'hulst, Reinhilde","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5133812194","display_name":"Dirk Van Hertem","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Van Hertem, Dirk","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.21660000085830688,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.21660000085830688,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.2079000025987625,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.19689999520778656,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacity-planning","display_name":"Capacity planning","score":0.6226000189781189},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.6219000220298767},{"id":"https://openalex.org/keywords/downstream","display_name":"Downstream (manufacturing)","score":0.48510000109672546},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.47760000824928284},{"id":"https://openalex.org/keywords/nameplate-capacity","display_name":"Nameplate capacity","score":0.4715999960899353},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.46380001306533813},{"id":"https://openalex.org/keywords/distribution","display_name":"Distribution (mathematics)","score":0.3637000024318695},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.32829999923706055},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.3203999996185303}],"concepts":[{"id":"https://openalex.org/C2781007418","wikidata":"https://www.wikidata.org/wiki/Q1456934","display_name":"Capacity planning","level":2,"score":0.6226000189781189},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6219000220298767},{"id":"https://openalex.org/C2776207758","wikidata":"https://www.wikidata.org/wiki/Q5303302","display_name":"Downstream (manufacturing)","level":2,"score":0.48510000109672546},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.47760000824928284},{"id":"https://openalex.org/C71554815","wikidata":"https://www.wikidata.org/wiki/Q200974","display_name":"Nameplate capacity","level":4,"score":0.4715999960899353},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.46380001306533813},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41110000014305115},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.3637000024318695},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3499999940395355},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3467000126838684},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.32829999923706055},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3203999996185303},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.31949999928474426},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.30970001220703125},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.3043000102043152},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2955000102519989},{"id":"https://openalex.org/C206888370","wikidata":"https://www.wikidata.org/wiki/Q844861","display_name":"Electric power distribution","level":3,"score":0.2921999990940094},{"id":"https://openalex.org/C2777819126","wikidata":"https://www.wikidata.org/wiki/Q1326624","display_name":"Electric utility","level":2,"score":0.28999999165534973},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.28850001096725464},{"id":"https://openalex.org/C2776613951","wikidata":"https://www.wikidata.org/wiki/Q7097788","display_name":"Operational planning","level":2,"score":0.2793000042438507},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.2784000039100647},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.26350000500679016},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.26330000162124634},{"id":"https://openalex.org/C149441793","wikidata":"https://www.wikidata.org/wiki/Q200726","display_name":"Probability distribution","level":2,"score":0.2621000111103058},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.25760000944137573}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2604.13926","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.13926","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2604.13926","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.13926","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.7627317905426025}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0],"increasing":[1],"penetration":[2],"of":[3,39,45,105,130,147],"Distributed":[4],"Energy":[5],"Resources":[6],"(DERs),":[7],"particularly":[8],"electric":[9],"vehicles,":[10],"heat":[11],"pumps,":[12],"and":[13,36,53,72,90,114,123,145],"photovoltaic":[14],"systems,":[15],"is":[16],"fundamentally":[17],"changing":[18],"power":[19],"flows":[20],"in":[21,69],"Low-Voltage":[22],"(LV)":[23],"distribution":[24],"networks.":[25],"Despite":[26],"this":[27],"transition,":[28],"Distribution":[29],"System":[30],"Operators":[31],"(DSOs)":[32],"often":[33],"lack":[34],"reliable":[35],"up-to-date":[37],"knowledge":[38,129],"the":[40,103],"DER":[41,65,79,95,107,132,148],"capacity":[42,134,143],"connected":[43],"downstream":[44],"LV":[46,84],"substations.":[47],"Limited":[48],"observability,":[49],"incomplete":[50],"topology":[51],"information,":[52],"restricted":[54],"access":[55],"to":[56,62,93,121],"customer-level":[57,99],"data":[58],"make":[59],"it":[60],"difficult":[61],"maintain":[63],"accurate":[64],"registries,":[66],"creating":[67],"uncertainty":[68],"both":[70],"operational":[71,122],"planning":[73,124],"processes.":[74],"This":[75],"paper":[76],"presents":[77],"aggregated":[78,131],"installed":[80,108,133],"capacity,":[81],"estimated":[82],"at":[83],"aggregation":[85],"points,":[86],"as":[87],"a":[88],"practical":[89],"scalable":[91],"approach":[92],"improving":[94],"awareness":[96],"without":[97],"requiring":[98],"monitoring.":[100],"We":[101],"define":[102],"problem":[104],"estimating":[106],"capacities":[109],"from":[110],"commonly":[111],"available":[112],"substation":[113],"feeder":[115],"measurements.":[116],"By":[117],"linking":[118],"these":[119],"estimates":[120],"needs,":[125],"we":[126],"discuss":[127],"how":[128],"enhances":[135],"DER-aware":[136],"forecasting,":[137],"congestion":[138],"management,":[139],"flexibility":[140],"quantification,":[141],"hosting":[142],"assessment,":[144],"monitoring":[146],"adoption.":[149]},"counts_by_year":[],"updated_date":"2026-07-01T06:00:48.157686","created_date":"2026-04-17T00:00:00"}
