{"id":"https://openalex.org/W7148935336","doi":"https://doi.org/10.48550/arxiv.2604.01338","title":"A Comprehensive Test System for Transmission Expansion Planning: Modeling N-1 Contingencies and Multi-Loading Scenarios","display_name":"A Comprehensive Test System for Transmission Expansion Planning: Modeling N-1 Contingencies and Multi-Loading Scenarios","publication_year":2026,"publication_date":"2026-04-01","ids":{"openalex":"https://openalex.org/W7148935336","doi":"https://doi.org/10.48550/arxiv.2604.01338"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2604.01338","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.01338","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2604.01338","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5132896054","display_name":"Bhuban Dhamala","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Dhamala, Bhuban","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5066421420","display_name":"Mona Ghassemi","orcid":"https://orcid.org/0000-0002-9086-0762"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ghassemi, Mona","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5132896054"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.4528999924659729,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.4528999924659729,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.1454000025987625,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.10679999738931656,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.6814000010490417},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.5965999960899353},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4934000074863434},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4867999851703644},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4742000102996826},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.47029998898506165},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4505000114440918},{"id":"https://openalex.org/keywords/power-flow","display_name":"Power flow","score":0.41499999165534973}],"concepts":[{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.6814000010490417},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5965999960899353},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5845999717712402},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5091999769210815},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4934000074863434},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4867999851703644},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4742000102996826},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.47029998898506165},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4505000114440918},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.41499999165534973},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.4023999869823456},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.3833000063896179},{"id":"https://openalex.org/C32866971","wikidata":"https://www.wikidata.org/wiki/Q7800957","display_name":"Tie line","level":4,"score":0.3652999997138977},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.351500004529953},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34709998965263367},{"id":"https://openalex.org/C97508593","wikidata":"https://www.wikidata.org/wiki/Q1359069","display_name":"Contingency","level":2,"score":0.33880001306533813},{"id":"https://openalex.org/C2986640423","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Transmission network","level":3,"score":0.33079999685287476},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3199999928474426},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.30730000138282776},{"id":"https://openalex.org/C132519959","wikidata":"https://www.wikidata.org/wiki/Q3077373","display_name":"Test method","level":2,"score":0.30320000648498535},{"id":"https://openalex.org/C7166840","wikidata":"https://www.wikidata.org/wiki/Q1199682","display_name":"System testing","level":2,"score":0.29840001463890076},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.2680000066757202},{"id":"https://openalex.org/C2777267654","wikidata":"https://www.wikidata.org/wiki/Q3519023","display_name":"Test (biology)","level":2,"score":0.2669000029563904},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2667999863624573}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2604.01338","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.01338","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2604.01338","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2604.01338","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"display_name":"Sustainable cities and communities","score":0.5416306257247925,"id":"https://metadata.un.org/sdg/11"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1,58,131],"presents":[2,132],"a":[3,141],"high-voltage":[4],"test":[5,21,87,119],"system":[6,88,103,120],"designed":[7],"specifically":[8],"for":[9,44,50,64,71,169,183],"transmission":[10,27,46,152],"expansion":[11],"planning":[12],"(TEP)":[13],"and":[14,33,67,80,110,155,171,188],"explores":[15],"multiple":[16,133],"TEP":[17,134,144,182],"studies":[18],"using":[19,38],"this":[20,118,130],"system.":[22],"The":[23,57,179],"network":[24],"incorporates":[25],"long":[26,45],"lines,":[28],"lines":[29,47],"are":[30,36,146],"accurately":[31,121],"modeled,":[32],"line":[34,55,153],"parameters":[35],"calculated":[37,187],"the":[39,51,85,100,123,138,193,202],"equivalent":[40],"\u03c0":[41],"circuit":[42],"model":[43],"to":[48,106,136,201],"account":[49],"distributed":[52],"nature":[53],"of":[54,125,151,181,192,198],"parameters.":[56],"provides":[59],"detailed":[60],"load":[61,92,139],"flow":[62,93],"analyses":[63],"both":[65],"normal":[66,170],"all":[68,116,166,172],"contingency":[69],"conditions":[70,75],"three":[72,176],"different":[73,149,177],"loading":[74,97,108],"(peak":[76],"load,":[77,79],"dominant":[78],"light":[81],"load),":[82],"demonstrating":[83],"that":[84],"proposed":[86],"offers":[89],"technically":[90],"feasible":[91],"solutions":[94],"at":[95,140],"these":[96],"scenarios.":[98,178],"As":[99],"real":[101,126],"power":[102,127,199],"is":[104,158,186],"subject":[105],"various":[107],"scenarios":[109],"should":[111],"be":[112],"effectively":[113],"operable":[114],"under":[115,175],"conditions,":[117],"replicates":[122],"properties":[124],"systems.":[128],"Furthermore,":[129],"cases":[135,145],"supply":[137],"new":[142,203],"location.":[143],"conducted":[147],"with":[148],"numbers":[150],"connections,":[154],"each":[156,184],"case":[157,185],"underscored":[159],"by":[160],"its":[161],"respective":[162],"maximum":[163],"capacity":[164],"satisfying":[165],"technical":[167],"requirements":[168],"single":[173],"contingencies":[174],"cost":[180,195],"compared":[189],"in":[190],"terms":[191],"average":[194],"per":[196],"MW":[197],"delivered":[200],"bus.":[204]},"counts_by_year":[],"updated_date":"2026-04-22T06:01:30.510260","created_date":"2026-04-04T00:00:00"}
