{"id":"https://openalex.org/W7140996804","doi":"https://doi.org/10.48550/arxiv.2603.25192","title":"Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems","display_name":"Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems","publication_year":2026,"publication_date":"2026-03-26","ids":{"openalex":"https://openalex.org/W7140996804","doi":"https://doi.org/10.48550/arxiv.2603.25192"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2603.25192","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.25192","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2603.25192","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5130726655","display_name":"Bingfang Li","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Li, Bingfang","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130760762","display_name":"Songhao Yang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yang, Songhao","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130724658","display_name":"Qinglan Wang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang, Qinglan","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130813652","display_name":"Xu Zhang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhang, Xu","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130733428","display_name":"Huan Xie","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xie, Huan","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130797211","display_name":"Chuan Qin","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Qin, Chuan","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5130780380","display_name":"Zhiguo Hao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hao, Zhiguo","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5130726655"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9269000291824341,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9269000291824341,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.011300000362098217,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.008299999870359898,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7760000228881836},{"id":"https://openalex.org/keywords/decoupling","display_name":"Decoupling (probability)","score":0.683899998664856},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.6722999811172485},{"id":"https://openalex.org/keywords/phase-locked-loop","display_name":"Phase-locked loop","score":0.6200000047683716},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.47780001163482666},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.47429999709129333},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.46299999952316284},{"id":"https://openalex.org/keywords/instability","display_name":"Instability","score":0.45719999074935913}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7760000228881836},{"id":"https://openalex.org/C205606062","wikidata":"https://www.wikidata.org/wiki/Q5249645","display_name":"Decoupling (probability)","level":2,"score":0.683899998664856},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6722999811172485},{"id":"https://openalex.org/C12707504","wikidata":"https://www.wikidata.org/wiki/Q52637","display_name":"Phase-locked loop","level":3,"score":0.6200000047683716},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47839999198913574},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.47780001163482666},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.47429999709129333},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.46299999952316284},{"id":"https://openalex.org/C207821765","wikidata":"https://www.wikidata.org/wiki/Q405372","display_name":"Instability","level":2,"score":0.45719999074935913},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.4221999943256378},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.39329999685287476},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.37299999594688416},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3709999918937683},{"id":"https://openalex.org/C162932704","wikidata":"https://www.wikidata.org/wiki/Q1058791","display_name":"Synchronizing","level":3,"score":0.36980000138282776},{"id":"https://openalex.org/C77405623","wikidata":"https://www.wikidata.org/wiki/Q598451","display_name":"System dynamics","level":2,"score":0.36320000886917114},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.35899999737739563},{"id":"https://openalex.org/C62354387","wikidata":"https://www.wikidata.org/wiki/Q875399","display_name":"Boundary (topology)","level":2,"score":0.3418000042438507},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.33059999346733093},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.32190001010894775},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3215000033378601},{"id":"https://openalex.org/C2779853468","wikidata":"https://www.wikidata.org/wiki/Q7662139","display_name":"Synchronism","level":3,"score":0.2712000012397766},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.25189998745918274}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2603.25192","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.25192","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2603.25192","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.25192","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"score":0.8610318303108215,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Deploying":[0],"synchronous":[1],"condensers":[2],"(SynCons)":[3],"near":[4],"grid-following":[5],"renewable":[6],"energy":[7],"sources":[8],"(GFLRs)":[9],"is":[10,67],"an":[11,30],"effective":[12],"and":[13,48,81,104,116,130,194],"increasingly":[14],"adopted":[15],"strategy":[16],"for":[17],"grid":[18],"support.":[19],"However,":[20,138],"the":[21,37,70,93,98,126,139,145,149,160,171,174,200,204],"potential":[22],"transient":[23,99,201],"instability":[24,42,141],"risks":[25],"in":[26],"such":[27],"configurations":[28],"remain":[29],"open":[31],"research":[32],"question.":[33],"This":[34],"study":[35,90,110],"investigates":[36],"mechanism":[38],"of":[39,95,101,163,203],"dominant":[40,140],"synchronization":[41],"source":[43,142],"transition":[44],"upon":[45],"SynCon":[46,86,151,153,184],"integration":[47],"proposes":[49],"a":[50,63,73,82,195,216],"straightforward":[51],"approach":[52],"to":[53,148,173,182],"enhance":[54,125],"system":[55,71,206],"stability":[56,100,128,202],"by":[57,188],"leveraging":[58],"their":[59,105],"interactive":[60],"characteristics.":[61],"Firstly,":[62],"dual-timescale":[64],"decoupling":[65],"model":[66],"established,":[68],"partitioning":[69],"into":[72],"fast":[74,172],"subsystem":[75,84],"representing":[76],"phase-locked":[77],"loop":[78],"(PLL)":[79],"dynamics":[80,122],"slow":[83,175],"characterizing":[85],"rotor":[87,185],"dynamics.":[88],"The":[89,109],"then":[91],"examines":[92],"influence":[94],"SynCons":[96],"on":[97],"nearby":[102],"PLLs":[103],"own":[106],"inherent":[107,191],"stability.":[108],"shows":[111],"that":[112,159],"SynCon's":[113,190],"voltage-source":[114],"characteristics":[115],"its":[117],"time-scale":[118],"separation":[119],"from":[120,144,170],"PLL":[121,147,164,180,197],"can":[123,166,207],"significantly":[124,209],"PLL's":[127],"boundary":[129],"mitigate":[131],"non-coherent":[132],"coupling":[133],"effects":[134],"among":[135],"multiple":[136],"GFLRs.":[137],"shifts":[143],"fast-time-scale":[146],"slow-time-scale":[150],"after":[152],"integration.":[154],"Crucially,":[155],"this":[156],"paper":[157],"demonstrates":[158],"damping":[161,181,198],"effect":[162],"control":[165],"also":[167],"be":[168,208],"transferred":[169],"time":[176],"scale,":[177],"allowing":[178],"well-tuned":[179],"suppress":[183],"acceleration.":[186],"Consequently,":[187],"utilizing":[189],"support":[192],"capability":[193],"simple":[196],"loop,":[199],"co-located":[205],"enhanced.":[210],"These":[211],"conclusions":[212],"are":[213],"validated":[214],"using":[215],"converter":[217],"controller-based":[218],"Hardware-in-the-Loop":[219],"(CHIL)":[220],"platform.":[221]},"counts_by_year":[],"updated_date":"2026-03-28T06:16:51.555046","created_date":"2026-03-28T00:00:00"}
