{"id":"https://openalex.org/W7140233418","doi":"https://doi.org/10.48550/arxiv.2603.21428","title":"Active-power control strategies in grid-forming power converters to improve transient stability in power systems with 100% converter-based generation","display_name":"Active-power control strategies in grid-forming power converters to improve transient stability in power systems with 100% converter-based generation","publication_year":2026,"publication_date":"2026-03-22","ids":{"openalex":"https://openalex.org/W7140233418","doi":"https://doi.org/10.48550/arxiv.2603.21428"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2603.21428","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.21428","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2603.21428","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"\u00c1vila-Mart\u00ednez, R\u00e9gulo E.","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"\u00c1vila-Mart\u00ednez, R\u00e9gulo E.","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Rouco, Luis","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Rouco, Luis","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Renedo, Javier","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Renedo, Javier","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Sigrist, Lukas","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sigrist, Lukas","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Garcia-Cerrada, Aurelio","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Garcia-Cerrada, Aurelio","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.881600022315979,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.881600022315979,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0771000012755394,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.011500000022351742,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7578999996185303},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7303000092506409},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.6686000227928162},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5914999842643738},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.5490999817848206},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4787999987602234},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.47110000252723694},{"id":"https://openalex.org/keywords/transient-response","display_name":"Transient response","score":0.4537999927997589}],"concepts":[{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7578999996185303},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7303000092506409},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.6686000227928162},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5914999842643738},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.5490999817848206},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5209000110626221},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4787999987602234},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.47110000252723694},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.4537999927997589},{"id":"https://openalex.org/C110407247","wikidata":"https://www.wikidata.org/wiki/Q122508","display_name":"Inertia","level":2,"score":0.44620001316070557},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.43720000982284546},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4293999969959259},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4156999886035919},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4032000005245209},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.3871000111103058},{"id":"https://openalex.org/C207269410","wikidata":"https://www.wikidata.org/wiki/Q595839","display_name":"Electronic stability control","level":2,"score":0.3091000020503998},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.3041999936103821},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.3034000098705292},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2815999984741211},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.27570000290870667},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.27489998936653137}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2603.21428","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.21428","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2603.21428","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.21428","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.6051746010780334}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Grid-forming":[0],"voltage":[1],"source":[2],"converters":[3],"(GFM-VSCs)":[4],"play":[5],"a":[6,29,90,103,111,155,162],"crucial":[7],"role":[8],"in":[9,33,43,75,81,118],"the":[10,68,96,150],"stability":[11,22,24,80],"of":[12,18,70,98],"power":[13,35,82],"systems":[14,83],"with":[15,84,135],"large":[16,26],"amounts":[17],"converter-based":[19,87],"generation.":[20],"Transient":[21],"(angle":[23],"under":[25],"disturbances)":[27],"is":[28],"critical":[30,141],"limiting":[31],"factor":[32],"stressed":[34],"systems.":[36],"Previous":[37],"studies":[38],"have":[39],"proposed":[40,117],"control":[41,61,73,92,114],"strategies":[42,74,122],"GFM-VSCs":[44,76],"to":[45,77],"improve":[46],"transient":[47,79,105],"stability.":[48],"These":[49],"approaches":[50],"typically":[51],"rely":[52],"on":[53,130],"suitable":[54],"current-limiting":[55],"algorithms,":[56],"voltage/reactive-power":[57],"and":[58,66,109,125],"active-power":[59,72],"supplementary":[60],"strategies.":[62],"This":[63],"paper":[64],"investigates":[65],"compares":[67],"effectiveness":[69],"three":[71],"enhance":[78],"100":[85,136],"%":[86,137],"generation:":[88],"(i)":[89],"wide-area":[91],"strategy":[93,115,148,160],"(TSP-WACS)":[94],"using":[95,127,165],"centre":[97],"inertia":[99],"(COI)":[100],"frequency,":[101],"(ii)":[102],"local":[104,113,166],"damping":[106],"method":[107],"(TSP-TDM),":[108],"(iii)":[110],"novel":[112],"(TSP-L)":[116],"this":[119],"work.":[120],"All":[121],"were":[123],"implemented":[124],"assessed":[126],"short-circuit":[128],"simulations":[129],"Kundur":[131],"two-area":[132],"test":[133],"system":[134],"GFM-VSC":[138],"generators,":[139],"demonstrating":[140],"clearing":[142],"time":[143],"(CCT)":[144],"improvement.":[145],"The":[146],"TSP-WACS":[147],"achieves":[149],"best":[151],"performance":[152],"but":[153],"requires":[154],"communication":[156],"infrastructure,":[157],"while":[158],"TSP-L":[159],"offers":[161],"simple-but-robust":[163],"alternative":[164],"measurements,":[167],"only.":[168]},"counts_by_year":[],"updated_date":"2026-04-25T08:17:42.794288","created_date":"2026-03-25T00:00:00"}
