{"id":"https://openalex.org/W7139962775","doi":"https://doi.org/10.48550/arxiv.2603.18424","title":"Deceiving Flexibility: A Stealthy False Data Injection Model in Vehicle-to-Grid Coordination","display_name":"Deceiving Flexibility: A Stealthy False Data Injection Model in Vehicle-to-Grid Coordination","publication_year":2026,"publication_date":"2026-03-19","ids":{"openalex":"https://openalex.org/W7139962775","doi":"https://doi.org/10.48550/arxiv.2603.18424"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2603.18424","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.18424","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2603.18424","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5130251827","display_name":"Kaan T. Gun","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Gun, Kaan T.","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065415603","display_name":"Xiaozhe Wang","orcid":"https://orcid.org/0000-0002-1887-0990"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang, Xiaozhe","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5044489791","display_name":"Danial Jafarigiv","orcid":"https://orcid.org/0000-0002-5801-9877"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jafarigiv, Danial","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9462000131607056,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9462000131607056,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.013000000268220901,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10761","display_name":"Vehicular Ad Hoc Networks (VANETs)","score":0.007300000172108412,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.6747000217437744},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.649399995803833},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5630000233650208},{"id":"https://openalex.org/keywords/limiting","display_name":"Limiting","score":0.5126000046730042},{"id":"https://openalex.org/keywords/adversary","display_name":"Adversary","score":0.47870001196861267},{"id":"https://openalex.org/keywords/state","display_name":"State (computer science)","score":0.4781000018119812},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.4587000012397766},{"id":"https://openalex.org/keywords/state-of-charge","display_name":"State of charge","score":0.44029998779296875},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.4341999888420105},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.43059998750686646}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6747000217437744},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.649399995803833},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5630000233650208},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5613999962806702},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.5126000046730042},{"id":"https://openalex.org/C41065033","wikidata":"https://www.wikidata.org/wiki/Q2825412","display_name":"Adversary","level":2,"score":0.47870001196861267},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.4781000018119812},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4765999913215637},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.4587000012397766},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.44029998779296875},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4341999888420105},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.43059998750686646},{"id":"https://openalex.org/C739882","wikidata":"https://www.wikidata.org/wiki/Q3560506","display_name":"Anomaly detection","level":2,"score":0.4106000065803528},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.40070000290870667},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3797000050544739},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34549999237060547},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.34470000863075256},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.3382999897003174},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.3264000117778778},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.32429999113082886},{"id":"https://openalex.org/C95713431","wikidata":"https://www.wikidata.org/wiki/Q631425","display_name":"Vulnerability (computing)","level":2,"score":0.3059000074863434},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.30169999599456787},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2976999878883362},{"id":"https://openalex.org/C72434380","wikidata":"https://www.wikidata.org/wiki/Q230930","display_name":"State space","level":2,"score":0.2930000126361847},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.2874000072479248},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.2840999960899353},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.27970001101493835},{"id":"https://openalex.org/C2986056383","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power flow","level":4,"score":0.27720001339912415},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.274399995803833},{"id":"https://openalex.org/C124681953","wikidata":"https://www.wikidata.org/wiki/Q339062","display_name":"Decomposition","level":2,"score":0.27090001106262207},{"id":"https://openalex.org/C205875254","wikidata":"https://www.wikidata.org/wiki/Q17156857","display_name":"Decentralised system","level":3,"score":0.2655999958515167},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.26429998874664307},{"id":"https://openalex.org/C2986957236","wikidata":"https://www.wikidata.org/wiki/Q8036562","display_name":"Energy resources","level":2,"score":0.26260000467300415},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.2565999925136566},{"id":"https://openalex.org/C207269410","wikidata":"https://www.wikidata.org/wiki/Q595839","display_name":"Electronic stability control","level":2,"score":0.25450000166893005},{"id":"https://openalex.org/C41550386","wikidata":"https://www.wikidata.org/wiki/Q529909","display_name":"Multi-agent system","level":2,"score":0.25200000405311584}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2603.18424","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.18424","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2603.18424","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.18424","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.6314551830291748,"id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Electric":[0],"vehicles":[1],"(EVs)":[2],"in":[3],"Vehicle-to-Grid":[4],"(V2G)":[5],"systems":[6],"act":[7],"as":[8,19],"distributed":[9],"energy":[10],"resources":[11],"that":[12,54,117],"support":[13],"grid":[14,124],"stability.":[15],"Centralized":[16],"coordination":[17],"such":[18],"the":[20,80,94,98,118,137],"extended":[21],"State":[22,84],"Space":[23],"Model":[24],"(eSSM)":[25],"enhances":[26],"scalability":[27],"and":[28,75,88,142],"estimation":[29],"efficiency":[30],"but":[31],"may":[32],"introduce":[33],"new":[34],"cyber-attack":[35],"surfaces.":[36],"This":[37],"paper":[38],"presents":[39],"a":[40,71],"stealthy":[41,120],"False":[42],"Data":[43],"Injection":[44],"Attack":[45],"(FDIA)":[46],"targeting":[47],"eSSM-based":[48],"V2G":[49,148],"coordination.":[50],"Unlike":[51],"prior":[52],"studies":[53],"assume":[55],"attackers":[56],"can":[57,96,122],"disrupt":[58],"physical":[59],"charging":[60],"or":[61],"discharging":[62],"processes,":[63],"we":[64],"consider":[65],"an":[66],"adversary":[67],"who":[68],"compromises":[69],"only":[70],"subset":[72],"of":[73,82,85,101],"EVs,":[74],"limiting":[76],"their":[77],"influence":[78],"to":[79,131,146],"manipulation":[81],"reported":[83],"Charge":[86],"(SoC)":[87],"power":[89],"measurements.":[90],"By":[91],"doing":[92],"so,":[93],"attacker":[95],"deceive":[97],"operator's":[99],"perception":[100],"fleet":[102],"flexibility":[103],"while":[104],"remaining":[105],"consistent":[106],"with":[107],"model-based":[108],"expectations,":[109],"thus":[110],"evading":[111],"anomaly":[112],"detection.":[113],"Numerical":[114],"simulations":[115],"show":[116],"proposed":[119],"FDIA":[121],"deteriorate":[123],"frequency":[125],"stability":[126],"even":[127],"without":[128],"direct":[129],"access":[130],"control":[132],"infrastructure.":[133],"These":[134],"findings":[135],"highlight":[136],"need":[138],"for":[139],"enhanced":[140],"detection":[141],"mitigation":[143],"mechanisms":[144],"tailored":[145],"aggregated":[147],"frameworks":[149]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2026-03-21T00:00:00"}