{"id":"https://openalex.org/W7135228572","doi":"https://doi.org/10.48550/arxiv.2603.11978","title":"Robust Parametric Microgrid Dispatch Under Endogenous Uncertainty of Operation- and Temperature-Dependent Battery Degradation","display_name":"Robust Parametric Microgrid Dispatch Under Endogenous Uncertainty of Operation- and Temperature-Dependent Battery Degradation","publication_year":2026,"publication_date":"2026-03-12","ids":{"openalex":"https://openalex.org/W7135228572","doi":"https://doi.org/10.48550/arxiv.2603.11978"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2603.11978","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.11978","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2603.11978","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5129050631","display_name":"Rui Xie","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xie, Rui","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100384613","display_name":"Jun Wang","orcid":"https://orcid.org/0000-0001-7359-1647"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang, Jun","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012845276","display_name":"Jiaxu Duan","orcid":"https://orcid.org/0000-0002-9107-9273"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Duan, Jiaxu","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5128994397","display_name":"Chao Ma","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ma, Chao","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5129020829","display_name":"Yunhui Liu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu, Yunhui","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5129002012","display_name":"Yue Chen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chen, Yue","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.4819999933242798,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.4819999933242798,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.4311999976634979,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.013899999670684338,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9276999831199646},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.7378000020980835},{"id":"https://openalex.org/keywords/degradation","display_name":"Degradation (telecommunications)","score":0.6425999999046326},{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.6032000184059143},{"id":"https://openalex.org/keywords/probabilistic-logic","display_name":"Probabilistic logic","score":0.5576000213623047},{"id":"https://openalex.org/keywords/economic-dispatch","display_name":"Economic dispatch","score":0.4742000102996826},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.45559999346733093},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4406000077724457}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9276999831199646},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.7378000020980835},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.6425999999046326},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6071000099182129},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.6032000184059143},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.5576000213623047},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5338000059127808},{"id":"https://openalex.org/C187633118","wikidata":"https://www.wikidata.org/wiki/Q1317949","display_name":"Economic dispatch","level":4,"score":0.4742000102996826},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.45559999346733093},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4406000077724457},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.36820000410079956},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3531000018119812},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.34790000319480896},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.3409000039100647},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3084000051021576},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.30550000071525574},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.2971000075340271},{"id":"https://openalex.org/C2776582896","wikidata":"https://www.wikidata.org/wiki/Q5368536","display_name":"State of charge","level":4,"score":0.2948000133037567},{"id":"https://openalex.org/C24574437","wikidata":"https://www.wikidata.org/wiki/Q7135228","display_name":"Parametric model","level":3,"score":0.2922999858856201},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.2745000123977661},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.27410000562667847},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.2728999853134155},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.27000001072883606}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2603.11978","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.11978","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2603.11978","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.11978","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"score":0.40027835965156555,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Batteries":[0],"play":[1],"a":[2,24,48,53,115],"critical":[3],"role":[4],"in":[5,43,82],"microgrid":[6,44,123],"energy":[7],"management":[8],"by":[9],"ensuring":[10],"power":[11],"balance,":[12],"enhancing":[13],"renewable":[14],"utilization,":[15],"and":[16,40,89,142],"reducing":[17],"operational":[18,41],"costs.":[19],"However,":[20],"battery":[21,38,70,79,86,131],"degradation":[22,39,84,102,132,141],"poses":[23],"significant":[25],"challenge,":[26],"particularly":[27],"under":[28],"extreme":[29],"temperatures.":[30],"This":[31],"paper":[32],"investigates":[33],"the":[34,62,75,126,130,148,151],"optimal":[35],"trade-off":[36],"between":[37],"costs":[42],"dispatch":[45,143],"to":[46],"find":[47],"robust":[49],"cost-effective":[50],"strategy":[51],"from":[52,61],"full":[54],"life-cycle":[55],"perspective.":[56],"A":[57],"key":[58],"challenge":[59],"arises":[60],"endogenous":[63],"uncertainty":[64],"(or":[65],"decision-dependent":[66],"uncertainty,":[67],"DDU)":[68],"of":[69,78,129,140,150],"degradation:":[71],"Dispatch":[72],"decisions":[73],"influence":[74],"probability":[76],"distribution":[77],"degradation,":[80],"while":[81],"turn":[83],"changes":[85],"operation":[87],"model":[88,103,117],"thus":[90],"affects":[91],"dispatch.":[92],"In":[93],"this":[94],"paper,":[95],"we":[96],"first":[97],"develop":[98],"an":[99],"XGBoost-based":[100],"probabilistic":[101],"trained":[104],"on":[105],"experimental":[106],"data":[107],"across":[108],"varying":[109],"temperature":[110],"conditions.":[111],"We":[112],"then":[113],"formulate":[114],"parametric":[116],"predictive":[118],"control":[119],"(MPC)":[120],"framework":[121],"for":[122],"dispatch,":[124],"where":[125],"weight":[127],"parameters":[128],"penalty":[133],"terms":[134],"are":[135],"tuned":[136],"through":[137],"long-term":[138],"simulation":[139],"interactions.":[144],"Case":[145],"studies":[146],"validate":[147],"effectiveness":[149],"proposed":[152],"approach.":[153]},"counts_by_year":[],"updated_date":"2026-07-01T06:00:48.157686","created_date":"2026-03-14T00:00:00"}
