{"id":"https://openalex.org/W7133312607","doi":"https://doi.org/10.48550/arxiv.2603.01902","title":"Dynamic Connectivity and Local Frequency Strength under Stochastic Variations","display_name":"Dynamic Connectivity and Local Frequency Strength under Stochastic Variations","publication_year":2026,"publication_date":"2026-03-02","ids":{"openalex":"https://openalex.org/W7133312607","doi":"https://doi.org/10.48550/arxiv.2603.01902"},"language":null,"primary_location":{"id":"doi:10.48550/arxiv.2603.01902","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.01902","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.48550/arxiv.2603.01902","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102758954","display_name":"Bruno Pinheiro","orcid":"https://orcid.org/0000-0003-2105-5265"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Pinheiro, Bruno","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5022937826","display_name":"DANIEL M. DOTTA","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dotta, Daniel","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5102758954"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.8431000113487244,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.8431000113487244,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.06129999831318855,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.015699999406933784,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.6398000121116638},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.5289000272750854},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.5146999955177307},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.4927000105381012},{"id":"https://openalex.org/keywords/inertia","display_name":"Inertia","score":0.4068000018596649},{"id":"https://openalex.org/keywords/stochastic-process","display_name":"Stochastic process","score":0.40549999475479126},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.391400009393692}],"concepts":[{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.6398000121116638},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.5289000272750854},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5146999955177307},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.4927000105381012},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45899999141693115},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.4253000020980835},{"id":"https://openalex.org/C110407247","wikidata":"https://www.wikidata.org/wiki/Q122508","display_name":"Inertia","level":2,"score":0.4068000018596649},{"id":"https://openalex.org/C8272713","wikidata":"https://www.wikidata.org/wiki/Q176737","display_name":"Stochastic process","level":2,"score":0.40549999475479126},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.391400009393692},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.38179999589920044},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.32440000772476196},{"id":"https://openalex.org/C2780898871","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Performance metric","level":2,"score":0.3163999915122986},{"id":"https://openalex.org/C165700671","wikidata":"https://www.wikidata.org/wiki/Q203484","display_name":"Laplace operator","level":2,"score":0.3149999976158142},{"id":"https://openalex.org/C121194460","wikidata":"https://www.wikidata.org/wiki/Q856741","display_name":"Random walk","level":2,"score":0.29179999232292175},{"id":"https://openalex.org/C28826006","wikidata":"https://www.wikidata.org/wiki/Q33521","display_name":"Applied mathematics","level":1,"score":0.29019999504089355},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.27869999408721924},{"id":"https://openalex.org/C127491075","wikidata":"https://www.wikidata.org/wiki/Q7617825","display_name":"Stochastic modelling","level":2,"score":0.26899999380111694},{"id":"https://openalex.org/C122123141","wikidata":"https://www.wikidata.org/wiki/Q176623","display_name":"Random variable","level":2,"score":0.26420000195503235}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.48550/arxiv.2603.01902","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.01902","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"doi:10.48550/arxiv.2603.01902","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.01902","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.4161895215511322}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1],"introduces":[2],"a":[3,40],"novel":[4],"metric,":[5],"termed":[6],"the":[7,14,24,29,35,45,50,58,64,83,94],"Generalized":[8],"Fiedler":[9],"Vector":[10],"(GFV),":[11],"to":[12,70],"evaluate":[13],"\\textit{dynamic":[15],"connectivity}":[16],"in":[17],"power":[18],"systems.":[19],"The":[20,80],"proposed":[21,84],"metric":[22],"leverages":[23],"network":[25],"connectivity,":[26],"represented":[27],"by":[28,44],"system":[30,53],"Laplacian":[31],"matrix,":[32],"together":[33],"with":[34],"nodal":[36],"inertia":[37],"distribution,":[38],"following":[39],"formulation":[41],"previously":[42],"developed":[43],"first":[46],"author.":[47],"By":[48],"capturing":[49],"interplay":[51],"between":[52],"topology":[54],"and":[55,76],"dynamic":[56],"properties,":[57],"GFV":[59],"provides":[60],"valuable":[61],"insights":[62],"for":[63],"optimal":[65],"siting":[66],"of":[67,82],"stochastic":[68],"generation":[69],"mitigate":[71],"its":[72],"impact":[73],"on":[74,93],"local":[75],"system-wide":[77],"frequency":[78],"variability.":[79],"effectiveness":[81],"approach":[85],"is":[86],"demonstrated":[87],"through":[88],"Monte":[89],"Carlo":[90],"simulations":[91],"performed":[92],"IEEE":[95],"68-bus":[96],"test":[97],"system.":[98]},"counts_by_year":[],"updated_date":"2026-03-04T07:09:34.246503","created_date":"2026-03-04T00:00:00"}
