{"id":"https://openalex.org/W7133314337","doi":"https://doi.org/10.48550/arxiv.2603.01198","title":"Digital Twin-Based Cooling System Optimization for Data Center","display_name":"Digital Twin-Based Cooling System Optimization for Data Center","publication_year":2026,"publication_date":"2026-03-01","ids":{"openalex":"https://openalex.org/W7133314337","doi":"https://doi.org/10.48550/arxiv.2603.01198"},"language":null,"primary_location":{"id":"pmh:doi:10.48550/arxiv.2603.01198","is_oa":true,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4406922384","display_name":"Open MIND","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Article"},"type":"article","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":null,"any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5121982378","display_name":"Shrenik Jadhav","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jadhav, Shrenik","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5127874600","display_name":"Zheng Liu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu, Zheng","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.3242,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.89236519,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.7480000257492065,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.7480000257492065,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13286","display_name":"Modeling and Simulation Systems","score":0.0869000032544136,"subfield":{"id":"https://openalex.org/subfields/1703","display_name":"Computational Theory and Mathematics"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.016200000420212746,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.5853000283241272},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.5275999903678894},{"id":"https://openalex.org/keywords/ashrae-90.1","display_name":"ASHRAE 90.1","score":0.5138999819755554},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.5083000063896179},{"id":"https://openalex.org/keywords/coolant","display_name":"Coolant","score":0.4553000032901764},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.42559999227523804},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4092999994754791},{"id":"https://openalex.org/keywords/cooling-load","display_name":"Cooling load","score":0.38609999418258667},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3840999901294708}],"concepts":[{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.5853000283241272},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.5275999903678894},{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.5138999819755554},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.5083000063896179},{"id":"https://openalex.org/C91914117","wikidata":"https://www.wikidata.org/wiki/Q1056832","display_name":"Coolant","level":2,"score":0.4553000032901764},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4278999865055084},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.42559999227523804},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4092999994754791},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.38609999418258667},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3840999901294708},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.3792000114917755},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.36800000071525574},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.35690000653266907},{"id":"https://openalex.org/C12241035","wikidata":"https://www.wikidata.org/wiki/Q1129714","display_name":"Cooling flow","level":3,"score":0.35269999504089355},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.34940001368522644},{"id":"https://openalex.org/C2986766224","wikidata":"https://www.wikidata.org/wiki/Q1156793","display_name":"System optimization","level":2,"score":0.3483999967575073},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.3481000065803528},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33559998869895935},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3296999931335449},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.31859999895095825},{"id":"https://openalex.org/C131675550","wikidata":"https://www.wikidata.org/wiki/Q7646884","display_name":"Surrogate model","level":2,"score":0.3061000108718872},{"id":"https://openalex.org/C2778547687","wikidata":"https://www.wikidata.org/wiki/Q193886","display_name":"Cooling tower","level":3,"score":0.30059999227523804},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.29190000891685486},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.2883000075817108},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.2825999855995178},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.27320000529289246},{"id":"https://openalex.org/C118530786","wikidata":"https://www.wikidata.org/wiki/Q1134732","display_name":"Instrumentation (computer programming)","level":2,"score":0.26750001311302185},{"id":"https://openalex.org/C14961307","wikidata":"https://www.wikidata.org/wiki/Q5377176","display_name":"Energy minimization","level":2,"score":0.26499998569488525},{"id":"https://openalex.org/C2988574769","wikidata":"https://www.wikidata.org/wiki/Q2259545","display_name":"Water flow","level":2,"score":0.2614000141620636},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.25780001282691956},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.25189998745918274},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.25049999356269836}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:doi:10.48550/arxiv.2603.01198","is_oa":true,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4406922384","display_name":"Open MIND","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Article"},{"id":"doi:10.48550/arxiv.2603.01198","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2603.01198","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"pmh:doi:10.48550/arxiv.2603.01198","is_oa":true,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4406922384","display_name":"Open MIND","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.4730071723461151}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Data":[0],"center":[1],"cooling":[2,32],"systems":[3],"consume":[4],"significant":[5],"auxiliary":[6],"energy,":[7],"yet":[8],"optimization":[9,117,127,135,149],"studies":[10],"rarely":[11],"quantify":[12],"the":[13,30,35,95,171,178,185,194],"gap":[14],"between":[15],"theoretically":[16],"optimal":[17],"and":[18,60,71,102,139,147,153,184],"operationally":[19],"deployable":[20],"control":[21],"strategies.":[22],"This":[23],"paper":[24],"develops":[25],"a":[26,41,89,103,115],"digital":[27],"twin":[28],"of":[29,78,92,94,136,150,165],"liquid":[31],"infrastructure":[33],"at":[34,175],"Frontier":[36],"exascale":[37],"supercomputer,":[38],"in":[39],"which":[40],"hot-temperature":[42],"water":[43],"system":[44,173],"comprises":[45],"three":[46,120],"parallel":[47],"subloops,":[48],"each":[49],"serving":[50],"dedicated":[51],"coolant":[52],"distribution":[53],"unit":[54],"clusters":[55],"through":[56,73],"plate":[57],"heat":[58],"exchangers":[59],"variable-speed":[61],"pumps.":[62],"The":[63,86,167],"surrogate":[64,113],"model":[65,87],"is":[66],"built":[67],"based":[68],"on":[69],"Modelica":[70],"validated":[72,112],"one":[74],"full":[75],"calendar":[76],"year":[77],"10-minute":[79],"operational":[80],"data":[81],"following":[82],"ASHRAE":[83],"Guideline":[84],"14.":[85],"achieves":[88,128],"subloop":[90],"coefficient":[91],"variation":[93],"root":[96],"mean":[97,105],"square":[98],"error":[99,107],"below":[100],"2.7%":[101],"normalized":[104],"bias":[106],"within":[108],"2.5%.":[109],"Using":[110],"this":[111],"model,":[114],"layered":[116],"framework":[118],"evaluates":[119],"progressively":[121],"constrained":[122],"strategies:":[123],"an":[124],"analytical":[125],"flow-only":[126],"20.4%":[129],"total":[130,144,162],"energy":[131,145,163],"saving,":[132,146],"unconstrained":[133],"joint":[134],"flow":[137,151,182,190,198],"rate":[138,152,158,191],"supply":[140,154,187],"temperature":[141,188],"demonstrates":[142],"30.1%":[143],"ramp-constrained":[148],"temperature,":[155],"enforcing":[156],"actuator":[157],"limits,":[159],"can":[160],"reach":[161],"saving":[164],"27.8%.":[166],"analysis":[168],"reveals":[169],"that":[170],"baseline":[172],"operates":[174],"2.9":[176],"times":[177],"minimum":[179],"thermally":[180],"safe":[181],"rate,":[183],"co-optimizing":[186],"with":[189],"nearly":[192],"doubles":[193],"savings":[195],"achievable":[196],"by":[197],"reduction":[199],"alone.":[200]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2026-03-04T00:00:00"}
