{"id":"https://openalex.org/W4399391341","doi":"https://doi.org/10.3390/s24113693","title":"The Accuracy of Evaluation of the Requirements of the Standards IEC 61000-3-2(12) with the Application of the Wideband Current Transducer","display_name":"The Accuracy of Evaluation of the Requirements of the Standards IEC 61000-3-2(12) with the Application of the Wideband Current Transducer","publication_year":2024,"publication_date":"2024-06-06","ids":{"openalex":"https://openalex.org/W4399391341","doi":"https://doi.org/10.3390/s24113693","pmid":"https://pubmed.ncbi.nlm.nih.gov/38894483"},"language":"en","primary_location":{"id":"doi:10.3390/s24113693","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24113693","pdf_url":"https://www.mdpi.com/1424-8220/24/11/3693/pdf?version=1717679800","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/24/11/3693/pdf?version=1717679800","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043113852","display_name":"Ernest Stano","orcid":"https://orcid.org/0000-0002-4706-5245"},"institutions":[{"id":"https://openalex.org/I188884621","display_name":"Lodz University of Technology","ror":"https://ror.org/00s8fpf52","country_code":"PL","type":"education","lineage":["https://openalex.org/I188884621"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Ernest Stano","raw_affiliation_strings":["Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland"],"raw_orcid":"https://orcid.org/0000-0002-4706-5245","affiliations":[{"raw_affiliation_string":"Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland","institution_ids":["https://openalex.org/I188884621"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063130856","display_name":"S. Wiak","orcid":"https://orcid.org/0000-0001-9622-9341"},"institutions":[{"id":"https://openalex.org/I188884621","display_name":"Lodz University of Technology","ror":"https://ror.org/00s8fpf52","country_code":"PL","type":"education","lineage":["https://openalex.org/I188884621"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Slawomir Wiak","raw_affiliation_strings":["Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland"],"raw_orcid":"https://orcid.org/0000-0001-9622-9341","affiliations":[{"raw_affiliation_string":"Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland","institution_ids":["https://openalex.org/I188884621"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5043113852"],"corresponding_institution_ids":["https://openalex.org/I188884621"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":0.3852,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.53785007,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":"24","issue":"11","first_page":"3693","last_page":"3693"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/harmonics","display_name":"Harmonics","score":0.8104187250137329},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.7054353952407837},{"id":"https://openalex.org/keywords/wideband","display_name":"Wideband","score":0.6649184226989746},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.5937645435333252},{"id":"https://openalex.org/keywords/electromagnetic-compatibility","display_name":"Electromagnetic compatibility","score":0.5748947858810425},{"id":"https://openalex.org/keywords/spectrum-analyzer","display_name":"Spectrum analyzer","score":0.5529216527938843},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4516451060771942},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.44432365894317627},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.426987886428833},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3788555860519409},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.15370896458625793},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12204849720001221}],"concepts":[{"id":"https://openalex.org/C188414643","wikidata":"https://www.wikidata.org/wiki/Q3001183","display_name":"Harmonics","level":3,"score":0.8104187250137329},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7054353952407837},{"id":"https://openalex.org/C2780202535","wikidata":"https://www.wikidata.org/wiki/Q4524457","display_name":"Wideband","level":2,"score":0.6649184226989746},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.5937645435333252},{"id":"https://openalex.org/C125470083","wikidata":"https://www.wikidata.org/wiki/Q747288","display_name":"Electromagnetic compatibility","level":2,"score":0.5748947858810425},{"id":"https://openalex.org/C158007255","wikidata":"https://www.wikidata.org/wiki/Q1055222","display_name":"Spectrum analyzer","level":2,"score":0.5529216527938843},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4516451060771942},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.44432365894317627},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.426987886428833},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3788555860519409},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.15370896458625793},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12204849720001221},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.3390/s24113693","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24113693","pdf_url":"https://www.mdpi.com/1424-8220/24/11/3693/pdf?version=1717679800","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:38894483","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/38894483","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:11175187","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/11175187","pdf_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC11175187/pdf/sensors-24-03693.pdf","source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"},{"id":"pmh:oai:doaj.org/article:b36b0a0fa7a44c8ca5fa183c8e4d9dd4","is_oa":false,"landing_page_url":"https://doaj.org/article/b36b0a0fa7a44c8ca5fa183c8e4d9dd4","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 24, Iss 11, p 3693 (2024)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/s24113693","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24113693","pdf_url":"https://www.mdpi.com/1424-8220/24/11/3693/pdf?version=1717679800","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8399999737739563,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4399391341.pdf"},"referenced_works_count":29,"referenced_works":["https://openalex.org/W1974430835","https://openalex.org/W2028616016","https://openalex.org/W2092515488","https://openalex.org/W2106894756","https://openalex.org/W2133782211","https://openalex.org/W2638382362","https://openalex.org/W2825045160","https://openalex.org/W2901359110","https://openalex.org/W2906651697","https://openalex.org/W2946361480","https://openalex.org/W2993247916","https://openalex.org/W3013005472","https://openalex.org/W3024273741","https://openalex.org/W3035518000","https://openalex.org/W3090139868","https://openalex.org/W3118269798","https://openalex.org/W3120380926","https://openalex.org/W3134446527","https://openalex.org/W4200223186","https://openalex.org/W4212851740","https://openalex.org/W4288045237","https://openalex.org/W4289941625","https://openalex.org/W4290465967","https://openalex.org/W4291821177","https://openalex.org/W4319431513","https://openalex.org/W4324146620","https://openalex.org/W4385253529","https://openalex.org/W4385878756","https://openalex.org/W6673609638"],"related_works":["https://openalex.org/W2370517014","https://openalex.org/W2039242888","https://openalex.org/W2515867587","https://openalex.org/W1838021708","https://openalex.org/W2535445299","https://openalex.org/W2391061712","https://openalex.org/W2094171095","https://openalex.org/W2020985248","https://openalex.org/W75722962","https://openalex.org/W2371900005"],"abstract_inverted_index":{"The":[0],"aim":[1],"of":[2,11,31,58,70,91,98,118],"this":[3,53],"paper":[4],"is":[5,104,111],"to":[6,26,62,76,113,129],"determine":[7,114],"the":[8,12,32,40,67,88,95,99,108,115,123,134],"conversion":[9],"accuracy":[10,97],"Danisense":[13],"DC200IF":[14],"(Danisense":[15],"A/S,":[16],"Taastrup,":[17],"Denmark)":[18],"wideband":[19],"current":[20,57,119],"transducer":[21],"for":[22,55],"its":[23,79,131],"possible":[24],"application":[25],"test":[27],"electromagnetic":[28],"compatibility":[29],"requirements":[30],"standards":[33],"IEC":[34,37,136],"61000-3-2":[35],"and":[36,65,82],"61000-3-12":[38],"with":[39,94,133],"digital":[41],"power":[42,102,125],"meter":[43],"Yokogawa":[44],"WT5000":[45],"(Yokogawa":[46],"Electric":[47],"Corporation,":[48],"Tokyo,":[49],"Japan).":[50],"To":[51],"obtain":[52],"goal":[54],"distorted":[56],"main":[59],"frequency":[60],"equal":[61],"50":[63],"Hz":[64,75,78],"in":[66,127],"frequencies":[68],"range":[69],"higher":[71,92],"harmonics":[72,93,120],"from":[73],"100":[74],"2500":[77],"amplitude":[80],"error":[81],"phase":[83],"shift":[84],"are":[85],"evaluated.":[86],"Moreover,":[87],"measurable":[89],"level":[90],"rated":[96],"used":[100],"precision":[101],"analyzer":[103],"also":[105],"investigated.":[106],"Finally,":[107],"measuring":[109],"system":[110],"applied":[112],"RMS":[116],"values":[117],"produced":[121],"by":[122],"audio":[124],"amplifier":[126],"order":[128],"assess":[130],"compliance":[132],"standard":[135],"61000-3-12.":[137]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}