{"id":"https://openalex.org/W4391956958","doi":"https://doi.org/10.3390/s24051359","title":"Diagnostics of Internal Defects in Composite Overhead Insulators Using an Optic E-Field Sensor","display_name":"Diagnostics of Internal Defects in Composite Overhead Insulators Using an Optic E-Field Sensor","publication_year":2024,"publication_date":"2024-02-20","ids":{"openalex":"https://openalex.org/W4391956958","doi":"https://doi.org/10.3390/s24051359","pmid":"https://pubmed.ncbi.nlm.nih.gov/38474895"},"language":"en","primary_location":{"id":"doi:10.3390/s24051359","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24051359","pdf_url":"https://www.mdpi.com/1424-8220/24/5/1359/pdf?version=1708424756","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/24/5/1359/pdf?version=1708424756","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073319655","display_name":"Damiano Fasani","orcid":"https://orcid.org/0000-0003-4383-1923"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Damiano Fasani","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012393015","display_name":"Luca Barbieri","orcid":"https://orcid.org/0000-0001-7296-9169"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Luca Barbieri","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":"https://orcid.org/0000-0001-7296-9169","affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019793113","display_name":"Andrea Villa","orcid":"https://orcid.org/0000-0002-3282-945X"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Andrea Villa","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":"https://orcid.org/0000-0002-3282-945X","affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000129288","display_name":"Daniele Palladini","orcid":"https://orcid.org/0000-0002-4293-1925"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Daniele Palladini","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":"https://orcid.org/0000-0002-4293-1925","affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076260682","display_name":"Roberto Malgesini","orcid":"https://orcid.org/0000-0002-9632-3829"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Malgesini","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047781160","display_name":"Giovanni D\u2019Avanzo","orcid":"https://orcid.org/0000-0001-9361-8309"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giovanni D\u2019Avanzo","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":"https://orcid.org/0000-0001-9361-8309","affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056894174","display_name":"Giacomo Buccella","orcid":"https://orcid.org/0000-0003-3080-6681"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giacomo Buccella","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5093961351","display_name":"Paolo Gadia","orcid":null},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Gadia","raw_affiliation_strings":["RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RSE SpA\u2014Ricerca sul Sistema Energetico, Via Raffaele Rubattino, 54, 20134 Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5073319655"],"corresponding_institution_ids":["https://openalex.org/I4210134634"],"apc_list":{"value":2600,"currency":"CHF","value_usd":3137},"apc_paid":{"value":2600,"currency":"CHF","value_usd":3137},"fwci":0.1787,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.36711151,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":96},"biblio":{"volume":"24","issue":"5","first_page":"1359","last_page":"1359"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12510","display_name":"Magneto-Optical Properties and Applications","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-conductor","display_name":"Electrical conductor","score":0.6150851249694824},{"id":"https://openalex.org/keywords/insulator","display_name":"Insulator (electricity)","score":0.5662713050842285},{"id":"https://openalex.org/keywords/composite-number","display_name":"Composite number","score":0.5621142983436584},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5318073034286499},{"id":"https://openalex.org/keywords/footprint","display_name":"Footprint","score":0.5278028249740601},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5173132419586182},{"id":"https://openalex.org/keywords/internal-heating","display_name":"Internal heating","score":0.46219781041145325},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.45767778158187866},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.4518444538116455},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.4412880539894104},{"id":"https://openalex.org/keywords/radiation","display_name":"Radiation","score":0.43379664421081543},{"id":"https://openalex.org/keywords/overhead-line","display_name":"Overhead line","score":0.4254944920539856},{"id":"https://openalex.org/keywords/thermal-conductivity","display_name":"Thermal conductivity","score":0.42513763904571533},{"id":"https://openalex.org/keywords/conductivity","display_name":"Conductivity","score":0.42135509848594666},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.41318485140800476},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.40549150109291077},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.39813995361328125},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.30869391560554504},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.2971673011779785},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2699164152145386},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2627407908439636},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.20248308777809143},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.16718736290931702},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.08848166465759277}],"concepts":[{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.6150851249694824},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.5662713050842285},{"id":"https://openalex.org/C104779481","wikidata":"https://www.wikidata.org/wiki/Q50707","display_name":"Composite number","level":2,"score":0.5621142983436584},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5318073034286499},{"id":"https://openalex.org/C132943942","wikidata":"https://www.wikidata.org/wiki/Q2562511","display_name":"Footprint","level":2,"score":0.5278028249740601},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5173132419586182},{"id":"https://openalex.org/C129716092","wikidata":"https://www.wikidata.org/wiki/Q912130","display_name":"Internal heating","level":2,"score":0.46219781041145325},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.45767778158187866},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.4518444538116455},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.4412880539894104},{"id":"https://openalex.org/C153385146","wikidata":"https://www.wikidata.org/wiki/Q18335","display_name":"Radiation","level":2,"score":0.43379664421081543},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.4254944920539856},{"id":"https://openalex.org/C97346530","wikidata":"https://www.wikidata.org/wiki/Q487005","display_name":"Thermal conductivity","level":2,"score":0.42513763904571533},{"id":"https://openalex.org/C131540310","wikidata":"https://www.wikidata.org/wiki/Q907564","display_name":"Conductivity","level":2,"score":0.42135509848594666},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.41318485140800476},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.40549150109291077},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.39813995361328125},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.30869391560554504},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2971673011779785},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2699164152145386},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2627407908439636},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.20248308777809143},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.16718736290931702},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.08848166465759277},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.3390/s24051359","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24051359","pdf_url":"https://www.mdpi.com/1424-8220/24/5/1359/pdf?version=1708424756","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:38474895","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/38474895","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":"Journal Article"},{"id":"pmh:oai:pubmedcentral.nih.gov:10934223","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/10934223","pdf_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC10934223/pdf/sensors-24-01359.pdf","source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"},{"id":"pmh:oai:doaj.org/article:9fd3d46a1d104a10a19780eb2a79ac89","is_oa":true,"landing_page_url":"https://doaj.org/article/9fd3d46a1d104a10a19780eb2a79ac89","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 24, Iss 5, p 1359 (2024)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/s24051359","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s24051359","pdf_url":"https://www.mdpi.com/1424-8220/24/5/1359/pdf?version=1708424756","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.5400000214576721,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4391956958.pdf","grobid_xml":"https://content.openalex.org/works/W4391956958.grobid-xml"},"referenced_works_count":23,"referenced_works":["https://openalex.org/W1963696696","https://openalex.org/W2003488339","https://openalex.org/W2057542810","https://openalex.org/W2091615344","https://openalex.org/W2148785300","https://openalex.org/W2149330905","https://openalex.org/W2479494214","https://openalex.org/W2769421180","https://openalex.org/W2780137554","https://openalex.org/W2797593330","https://openalex.org/W2909209144","https://openalex.org/W2947852850","https://openalex.org/W2967280889","https://openalex.org/W2990005274","https://openalex.org/W3023479145","https://openalex.org/W3111840904","https://openalex.org/W3186135827","https://openalex.org/W4206988185","https://openalex.org/W4283155558","https://openalex.org/W4285188427","https://openalex.org/W4285815866","https://openalex.org/W4385413504","https://openalex.org/W4391338264"],"related_works":["https://openalex.org/W1971906190","https://openalex.org/W3193611504","https://openalex.org/W1526211713","https://openalex.org/W1928872482","https://openalex.org/W1984526534","https://openalex.org/W2056548600","https://openalex.org/W2607748257","https://openalex.org/W1989489387","https://openalex.org/W2148342402","https://openalex.org/W2313952605"],"abstract_inverted_index":{"Composite":[0],"insulators":[1,94],"for":[2],"high-voltage":[3],"overhead":[4],"lines":[5],"have":[6],"better":[7],"performances":[8],"and":[9],"are":[10,34,171],"lighter":[11],"than":[12,202],"traditional":[13],"designs,":[14],"especially":[15,38],"in":[16],"heavily":[17],"polluted":[18],"areas.":[19],"However,":[20,184],"since":[21,150],"it":[22,185],"is":[23,57,182,193],"a":[24,90,105,132,163,179,189],"relatively":[25],"recent":[26],"technology,":[27],"reliable":[28],"methods":[29],"to":[30,41,84,115,159],"perform":[31],"live-line":[32],"diagnostics":[33],"still":[35],"under":[36],"development,":[37],"with":[39,128,173],"regard":[40],"internal":[42,71,87,148],"defects,":[43],"which":[44],"provide":[45],"few":[46],"external":[47],"symptoms.":[48],"Thermal":[49],"cameras":[50],"can":[51,65,142],"be":[52],"employed,":[53],"but":[54],"their":[55],"use":[56],"not":[58,194],"always":[59],"straightforward":[60],"as":[61],"the":[62,67,86,117,121,140,144,154,160,167,174,203,206],"sun":[63],"radiation":[64],"hide":[66],"thermal":[68],"footprint":[69],"of":[70,89,92,120,146,162,199,205],"degenerative":[72],"effects.":[73],"In":[74],"this":[75],"work,":[76],"an":[77,147],"optical":[78],"E-field":[79,101,126,155,169],"sensor":[80,141],"has":[81,111],"been":[82,112],"used":[83],"diagnose":[85],"defects":[88,122],"set":[91],"composite":[93],"(bandwidth":[95],"200":[96],"mHz-50":[97],"MHz,":[98],"min.":[99],"detectable":[100],"100":[102],"V/m).":[103],"Moreover,":[104,166],"modelling":[106],"activity":[107],"using":[108],"finite":[109],"elements":[110],"carried":[113],"out":[114],"identify":[116],"possible":[118],"nature":[119],"by":[123],"comparing":[124],"experimental":[125],"profiles":[127,170],"those":[129],"simulated":[130,176],"assuming":[131],"specific":[133],"defect":[134,181,190],"geometry.":[135],"The":[136],"results":[137],"show":[138],"that":[139,188],"detect":[143],"presence":[145,152],"defect,":[149],"its":[151],"distorts":[153],"profile":[156,161],"when":[157,178],"compared":[158],"sound":[164],"insulator.":[165],"measured":[168],"compatible":[172],"corresponding":[175],"ones":[177],"conductive":[180],"considered.":[183],"was":[186],"observed":[187],"whose":[191],"conductivity":[192,204],"at":[195],"least":[196],"two":[197],"orders":[198],"magnitude":[200],"greater":[201],"surroundings":[207],"remains":[208],"undetected.":[209]},"counts_by_year":[{"year":2025,"cited_by_count":2}],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2025-10-10T00:00:00"}