{"id":"https://openalex.org/W4386608134","doi":"https://doi.org/10.3390/s23187774","title":"Image Reconstruction Using Supervised Learning in Wearable Electrical Impedance Tomography of the Thorax","display_name":"Image Reconstruction Using Supervised Learning in Wearable Electrical Impedance Tomography of the Thorax","publication_year":2023,"publication_date":"2023-09-09","ids":{"openalex":"https://openalex.org/W4386608134","doi":"https://doi.org/10.3390/s23187774","pmid":"https://pubmed.ncbi.nlm.nih.gov/37765831"},"language":"en","primary_location":{"id":"doi:10.3390/s23187774","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23187774","pdf_url":"https://www.mdpi.com/1424-8220/23/18/7774/pdf?version=1694251005","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/23/18/7774/pdf?version=1694251005","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5044386511","display_name":"Mikhail Ivanenko","orcid":"https://orcid.org/0009-0006-8682-2751"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mikhail Ivanenko","raw_affiliation_strings":["Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0009-0006-8682-2751","affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061167438","display_name":"Waldemar T. Smolik","orcid":"https://orcid.org/0000-0002-1524-5049"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Waldemar T. Smolik","raw_affiliation_strings":["Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-1524-5049","affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001394482","display_name":"Damian Wanta","orcid":"https://orcid.org/0000-0002-1596-6524"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Damian Wanta","raw_affiliation_strings":["Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-1596-6524","affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077917330","display_name":"Mateusz Midura","orcid":"https://orcid.org/0000-0002-2449-0652"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mateusz Midura","raw_affiliation_strings":["Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-2449-0652","affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042720633","display_name":"Przemys\u0142aw Wr\u00f3blewski","orcid":"https://orcid.org/0000-0002-6713-9088"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Przemys\u0142aw Wr\u00f3blewski","raw_affiliation_strings":["Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-6713-9088","affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102510879","display_name":"Xiaohan Hou","orcid":null},"institutions":[{"id":"https://openalex.org/I176808543","display_name":"Liaoning Technical University","ror":"https://ror.org/01n2bd587","country_code":"CN","type":"education","lineage":["https://openalex.org/I176808543"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaohan Hou","raw_affiliation_strings":["Faculty of Electrical and Control Engineering, Liaoning Technical University, No. 188 Longwan Street, Huludao 125105, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Control Engineering, Liaoning Technical University, No. 188 Longwan Street, Huludao 125105, China","institution_ids":["https://openalex.org/I176808543"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078582991","display_name":"Xiaoheng Yan","orcid":"https://orcid.org/0000-0002-9048-9035"},"institutions":[{"id":"https://openalex.org/I176808543","display_name":"Liaoning Technical University","ror":"https://ror.org/01n2bd587","country_code":"CN","type":"education","lineage":["https://openalex.org/I176808543"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaoheng Yan","raw_affiliation_strings":["Faculty of Electrical and Control Engineering, Liaoning Technical University, No. 188 Longwan Street, Huludao 125105, China"],"raw_orcid":"https://orcid.org/0000-0002-9048-9035","affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Control Engineering, Liaoning Technical University, No. 188 Longwan Street, Huludao 125105, China","institution_ids":["https://openalex.org/I176808543"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5061167438"],"corresponding_institution_ids":["https://openalex.org/I108403487"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2673},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2673},"fwci":1.8434,"has_fulltext":true,"cited_by_count":22,"citation_normalized_percentile":{"value":0.85491902,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"23","issue":"18","first_page":"7774","last_page":"7774"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9911999702453613,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9639999866485596,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.6439037322998047},{"id":"https://openalex.org/keywords/electrical-impedance-tomography","display_name":"Electrical impedance tomography","score":0.6414583325386047},{"id":"https://openalex.org/keywords/iterative-reconstruction","display_name":"Iterative reconstruction","score":0.600066602230072},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5850400328636169},{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.5773150324821472},{"id":"https://openalex.org/keywords/deep-learning","display_name":"Deep learning","score":0.5527231097221375},{"id":"https://openalex.org/keywords/convolutional-neural-network","display_name":"Convolutional neural network","score":0.5321599245071411},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.5195955634117126},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.43367108702659607},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.3548593521118164},{"id":"https://openalex.org/keywords/tomography","display_name":"Tomography","score":0.32293975353240967},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.11160272359848022},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.101502925157547}],"concepts":[{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.6439037322998047},{"id":"https://openalex.org/C155175808","wikidata":"https://www.wikidata.org/wiki/Q1326472","display_name":"Electrical impedance tomography","level":3,"score":0.6414583325386047},{"id":"https://openalex.org/C141379421","wikidata":"https://www.wikidata.org/wiki/Q6094427","display_name":"Iterative reconstruction","level":2,"score":0.600066602230072},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5850400328636169},{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.5773150324821472},{"id":"https://openalex.org/C108583219","wikidata":"https://www.wikidata.org/wiki/Q197536","display_name":"Deep learning","level":2,"score":0.5527231097221375},{"id":"https://openalex.org/C81363708","wikidata":"https://www.wikidata.org/wiki/Q17084460","display_name":"Convolutional neural network","level":2,"score":0.5321599245071411},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.5195955634117126},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.43367108702659607},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.3548593521118164},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.32293975353240967},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.11160272359848022},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.101502925157547}],"mesh":[{"descriptor_ui":"D000069553","descriptor_name":"Supervised Machine Learning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000069553","descriptor_name":"Supervised Machine Learning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000069553","descriptor_name":"Supervised Machine Learning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010996","descriptor_name":"Pleural Effusion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010996","descriptor_name":"Pleural Effusion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010996","descriptor_name":"Pleural Effusion","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011030","descriptor_name":"Pneumothorax","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011030","descriptor_name":"Pneumothorax","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011030","descriptor_name":"Pneumothorax","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014054","descriptor_name":"Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s23187774","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23187774","pdf_url":"https://www.mdpi.com/1424-8220/23/18/7774/pdf?version=1694251005","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:37765831","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/37765831","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:10538128","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/10538128","pdf_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC10538128/pdf/sensors-23-07774.pdf","source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"},{"id":"pmh:oai:doaj.org/article:3f9646543dcf4da8961f94064a96a2e0","is_oa":true,"landing_page_url":"https://doaj.org/article/3f9646543dcf4da8961f94064a96a2e0","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 23, Iss 18, p 7774 (2023)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/23/18/7774/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s23187774","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s23187774","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23187774","pdf_url":"https://www.mdpi.com/1424-8220/23/18/7774/pdf?version=1694251005","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.49000000953674316}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4386608134.pdf"},"referenced_works_count":75,"referenced_works":["https://openalex.org/W1836465849","https://openalex.org/W1991540127","https://openalex.org/W1997923910","https://openalex.org/W2020432065","https://openalex.org/W2030525720","https://openalex.org/W2035414577","https://openalex.org/W2039534575","https://openalex.org/W2043656208","https://openalex.org/W2044900618","https://openalex.org/W2053510218","https://openalex.org/W2106050534","https://openalex.org/W2113761410","https://openalex.org/W2132160196","https://openalex.org/W2138248326","https://openalex.org/W2138319203","https://openalex.org/W2141002303","https://openalex.org/W2151220638","https://openalex.org/W2154532813","https://openalex.org/W2164341173","https://openalex.org/W2168905460","https://openalex.org/W2413435669","https://openalex.org/W2607406448","https://openalex.org/W2753801451","https://openalex.org/W2755026805","https://openalex.org/W2794712637","https://openalex.org/W2803224943","https://openalex.org/W2896989731","https://openalex.org/W2905450017","https://openalex.org/W2910112947","https://openalex.org/W2910732135","https://openalex.org/W2924523132","https://openalex.org/W2941524667","https://openalex.org/W2963073614","https://openalex.org/W2963570578","https://openalex.org/W2990850413","https://openalex.org/W3009936147","https://openalex.org/W3013110140","https://openalex.org/W3021094251","https://openalex.org/W3034194810","https://openalex.org/W3098020164","https://openalex.org/W3101765447","https://openalex.org/W3125671608","https://openalex.org/W3127450075","https://openalex.org/W3140349852","https://openalex.org/W3158580046","https://openalex.org/W3180753966","https://openalex.org/W3195914826","https://openalex.org/W3203160629","https://openalex.org/W3203639587","https://openalex.org/W3204368240","https://openalex.org/W3204805281","https://openalex.org/W3204900076","https://openalex.org/W4200071351","https://openalex.org/W4224235329","https://openalex.org/W4226091366","https://openalex.org/W4281676262","https://openalex.org/W4282836495","https://openalex.org/W4291805238","https://openalex.org/W4293242669","https://openalex.org/W4295308144","https://openalex.org/W4308347301","https://openalex.org/W4310859889","https://openalex.org/W4311331221","https://openalex.org/W4317625880","https://openalex.org/W4319719354","https://openalex.org/W4319986922","https://openalex.org/W4328050831","https://openalex.org/W4362691822","https://openalex.org/W4367279143","https://openalex.org/W4385218226","https://openalex.org/W6631190155","https://openalex.org/W6684953790","https://openalex.org/W6715056836","https://openalex.org/W6744244150","https://openalex.org/W6785134948"],"related_works":["https://openalex.org/W4312417841","https://openalex.org/W4321369474","https://openalex.org/W2731899572","https://openalex.org/W3133861977","https://openalex.org/W4200173597","https://openalex.org/W3116150086","https://openalex.org/W2028912824","https://openalex.org/W1967369962","https://openalex.org/W2390667333","https://openalex.org/W4308555761"],"abstract_inverted_index":{"Electrical":[0],"impedance":[1,20],"tomography":[2,21],"(EIT)":[3],"is":[4,23,47,290],"a":[5,14,24,35,43,92,115,122,138,317],"non-invasive":[6],"technique":[7,28],"for":[8,50,111,190,210],"visualizing":[9],"the":[10,56,83,134,158,162,168,183,196,257,262,270,323],"internal":[11],"structure":[12],"of":[13,55,85,95,106,137,148,161,325],"human":[15],"body.":[16],"Capacitively":[17],"coupled":[18],"electrical":[19,159],"(CCEIT)":[22],"new":[25],"contactless":[26],"EIT":[27,51],"that":[29,42,276,334],"can":[30],"potentially":[31],"be":[32],"used":[33,110,181,193,267],"as":[34,226,243],"wearable":[36],"device.":[37],"Recent":[38],"studies":[39,57],"have":[40],"shown":[41],"machine":[44],"learning-based":[45],"approach":[46],"very":[48],"promising":[49],"image":[52,89,113,211,271,293],"reconstruction.":[53,212],"Most":[54],"concern":[58],"models":[59],"containing":[60],"up":[61],"to":[62,78,194,268,340],"22":[63],"electrodes":[64,96,179],"and":[65,121,143,153,172,199,220,230,252,299],"focus":[66],"on":[67,239,296],"using":[68,157,292,308,316],"different":[69,104],"artificial":[70,107,203],"neural":[71,119,204,301],"network":[72,120,126],"models,":[73],"from":[74],"simple":[75],"shallow":[76],"networks":[77,87,108,205,219,302],"complex":[79],"convolutional":[80,86],"networks.":[81],"However,":[82,329],"use":[84],"in":[88,182,303,322],"reconstruction":[90,223,294],"with":[91,141,176,208,232],"higher":[93],"number":[94],"requires":[97],"further":[98],"investigation.":[99],"In":[100],"this":[101],"work,":[102],"two":[103],"architectures":[105],"were":[109,155,206],"CCEIT":[112],"reconstruction:":[114],"fully":[116,318],"connected":[117,319],"deep":[118,300],"conditional":[123],"generative":[124],"adversarial":[125],"(cGAN).":[127],"The":[128,164,174,186,273,305],"training":[129],"dataset":[130],"was":[131,180,192,215,237,266],"generated":[132],"by":[133,261,285],"numerical":[135,184],"simulation":[136],"thorax":[139,165],"phantom":[140,166],"healthy":[142],"illness-affected":[144],"lungs.":[145,173],"Three":[146],"kinds":[147],"illnesses,":[149],"pneumothorax,":[150],"pleural":[151,288],"effusion,":[152],"hydropneumothorax,":[154],"modeled":[156],"properties":[160],"tissues.":[163],"included":[167],"heart,":[169],"aorta,":[170],"spine,":[171],"sensor":[175],"32":[177],"area":[178],"model.":[185],"ECTsim":[187],"custom-designed":[188],"toolbox":[189],"Matlab":[191],"solve":[195],"forward":[197],"problem":[198],"measurement":[200,327],"simulation.":[201],"Two":[202],"trained":[207],"supervision":[209],"Reconstruction":[213],"quality":[214],"compared":[216],"between":[217],"those":[218,314],"one-step":[221],"algebraic":[222,336],"methods":[224,337],"such":[225,242],"linear":[227],"back":[228],"projection":[229],"pseudoinverse":[231],"Tikhonov":[233],"regularization.":[234],"This":[235],"evaluation":[236],"based":[238,295],"pixel-to-pixel":[240],"metrics":[241],"root-mean-square":[244],"error,":[245],"structural":[246],"similarity":[247],"index,":[248],"2D":[249],"correlation":[250],"coefficient,":[251],"peak":[253],"signal-to-noise":[254],"ratio.":[255],"Additionally,":[256],"diagnostic":[258,330],"value":[259,331],"measured":[260],"ROC":[263],"AUC":[264],"metric":[265],"assess":[269],"quality.":[272],"results":[274,306],"showed":[275,333],"obtaining":[277],"information":[278],"about":[279],"regional":[280],"lung":[281],"function":[282],"(regions":[283],"affected":[284],"pneumothorax":[286],"or":[287],"effusion)":[289],"possible":[291],"supervised":[297],"learning":[298],"EIT.":[304],"obtained":[307,315],"cGAN":[309],"are":[310],"strongly":[311],"better":[312],"than":[313],"network,":[320],"especially":[321],"case":[324],"noisy":[326],"data.":[328],"estimation":[332],"even":[335],"allow":[338],"us":[339],"obtain":[341],"satisfactory":[342],"results.":[343]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":11},{"year":2024,"cited_by_count":7}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
