{"id":"https://openalex.org/W4313435396","doi":"https://doi.org/10.3390/s23010001","title":"A Review of Data-Driven Approaches and Techniques for Fault Detection and Diagnosis in HVAC Systems","display_name":"A Review of Data-Driven Approaches and Techniques for Fault Detection and Diagnosis in HVAC Systems","publication_year":2022,"publication_date":"2022-12-20","ids":{"openalex":"https://openalex.org/W4313435396","doi":"https://doi.org/10.3390/s23010001","pmid":"https://pubmed.ncbi.nlm.nih.gov/36616600"},"language":"en","primary_location":{"id":"doi:10.3390/s23010001","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23010001","pdf_url":"https://www.mdpi.com/1424-8220/23/1/1/pdf?version=1672220710","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/23/1/1/pdf?version=1672220710","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081379547","display_name":"Iva Mateti\u0107","orcid":"https://orcid.org/0000-0002-8722-3965"},"institutions":[{"id":"https://openalex.org/I154347574","display_name":"University of Rijeka","ror":"https://ror.org/05r8dqr10","country_code":"HR","type":"education","lineage":["https://openalex.org/I154347574"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Iva Mateti\u0107","raw_affiliation_strings":["Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia"],"raw_orcid":"https://orcid.org/0000-0002-8722-3965","affiliations":[{"raw_affiliation_string":"Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081398821","display_name":"Ivan \u0160tajduhar","orcid":"https://orcid.org/0000-0003-4758-7972"},"institutions":[{"id":"https://openalex.org/I154347574","display_name":"University of Rijeka","ror":"https://ror.org/05r8dqr10","country_code":"HR","type":"education","lineage":["https://openalex.org/I154347574"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Ivan \u0160tajduhar","raw_affiliation_strings":["Center for Artificial Intelligence and Cybersecurity, University of Rijeka, R. Matejcic 2, HR-51000 Rijeka, Croatia","Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia"],"raw_orcid":"https://orcid.org/0000-0003-4758-7972","affiliations":[{"raw_affiliation_string":"Center for Artificial Intelligence and Cybersecurity, University of Rijeka, R. Matejcic 2, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]},{"raw_affiliation_string":"Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063290502","display_name":"Igor Wolf","orcid":"https://orcid.org/0000-0002-8720-9549"},"institutions":[{"id":"https://openalex.org/I154347574","display_name":"University of Rijeka","ror":"https://ror.org/05r8dqr10","country_code":"HR","type":"education","lineage":["https://openalex.org/I154347574"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Igor Wolf","raw_affiliation_strings":["Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia"],"raw_orcid":"https://orcid.org/0000-0002-8720-9549","affiliations":[{"raw_affiliation_string":"Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091215228","display_name":"Sandi Ljubi\u0107","orcid":"https://orcid.org/0000-0003-3456-8369"},"institutions":[{"id":"https://openalex.org/I154347574","display_name":"University of Rijeka","ror":"https://ror.org/05r8dqr10","country_code":"HR","type":"education","lineage":["https://openalex.org/I154347574"]}],"countries":["HR"],"is_corresponding":true,"raw_author_name":"Sandi Ljubic","raw_affiliation_strings":["Center for Artificial Intelligence and Cybersecurity, University of Rijeka, R. Matejcic 2, HR-51000 Rijeka, Croatia","Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia"],"raw_orcid":"https://orcid.org/0000-0003-3456-8369","affiliations":[{"raw_affiliation_string":"Center for Artificial Intelligence and Cybersecurity, University of Rijeka, R. Matejcic 2, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]},{"raw_affiliation_string":"Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka, Croatia","institution_ids":["https://openalex.org/I154347574"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5091215228"],"corresponding_institution_ids":["https://openalex.org/I154347574"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2673},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2673},"fwci":4.4976,"has_fulltext":true,"cited_by_count":70,"citation_normalized_percentile":{"value":0.95918044,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"23","issue":"1","first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9936000108718872,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11667","display_name":"Advanced Chemical Sensor Technologies","score":0.9531999826431274,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.956957221031189},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5576754808425903},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5164790153503418},{"id":"https://openalex.org/keywords/heuristics","display_name":"Heuristics","score":0.4798526167869568},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.4795522391796112},{"id":"https://openalex.org/keywords/domain","display_name":"Domain (mathematical analysis)","score":0.45663315057754517},{"id":"https://openalex.org/keywords/data-driven","display_name":"Data-driven","score":0.44384029507637024},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.443208783864975},{"id":"https://openalex.org/keywords/focus","display_name":"Focus (optics)","score":0.4231989085674286},{"id":"https://openalex.org/keywords/enhanced-data-rates-for-gsm-evolution","display_name":"Enhanced Data Rates for GSM Evolution","score":0.4190866947174072},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.37556958198547363},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3460671901702881},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33651480078697205},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.21657490730285645},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.15873542428016663},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.0967969000339508}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.956957221031189},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5576754808425903},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5164790153503418},{"id":"https://openalex.org/C127705205","wikidata":"https://www.wikidata.org/wiki/Q5748245","display_name":"Heuristics","level":2,"score":0.4798526167869568},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4795522391796112},{"id":"https://openalex.org/C36503486","wikidata":"https://www.wikidata.org/wiki/Q11235244","display_name":"Domain (mathematical analysis)","level":2,"score":0.45663315057754517},{"id":"https://openalex.org/C2780440489","wikidata":"https://www.wikidata.org/wiki/Q5227278","display_name":"Data-driven","level":2,"score":0.44384029507637024},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.443208783864975},{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.4231989085674286},{"id":"https://openalex.org/C162307627","wikidata":"https://www.wikidata.org/wiki/Q204833","display_name":"Enhanced Data Rates for GSM Evolution","level":2,"score":0.4190866947174072},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.37556958198547363},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3460671901702881},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33651480078697205},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.21657490730285645},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.15873542428016663},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0967969000339508},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D000389","descriptor_name":"Air Conditioning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000389","descriptor_name":"Air Conditioning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000389","descriptor_name":"Air Conditioning","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006361","descriptor_name":"Heating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006361","descriptor_name":"Heating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006361","descriptor_name":"Heating","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014691","descriptor_name":"Ventilation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014691","descriptor_name":"Ventilation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014691","descriptor_name":"Ventilation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016902","descriptor_name":"Air Pollution, Indoor","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D016902","descriptor_name":"Air Pollution, Indoor","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D016902","descriptor_name":"Air Pollution, Indoor","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true}],"locations_count":5,"locations":[{"id":"doi:10.3390/s23010001","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23010001","pdf_url":"https://www.mdpi.com/1424-8220/23/1/1/pdf?version=1672220710","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:36616600","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/36616600","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:9824457","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/9824457","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"},{"id":"pmh:oai:doaj.org/article:7e542f5f32e54f4383ba2a003523741a","is_oa":false,"landing_page_url":"https://doaj.org/article/7e542f5f32e54f4383ba2a003523741a","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 23, Iss 1, p 1 (2022)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/23/1/1/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s23010001","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 23; Issue 1; Pages: 1","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s23010001","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s23010001","pdf_url":"https://www.mdpi.com/1424-8220/23/1/1/pdf?version=1672220710","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.46000000834465027,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G3019550128","display_name":null,"funder_award_id":"KK.01.2.1.02.0303","funder_id":"https://openalex.org/F4320335322","funder_display_name":"European Regional Development Fund"},{"id":"https://openalex.org/G4586600021","display_name":null,"funder_award_id":"KK.01.2.1.02.","funder_id":"https://openalex.org/F4320335322","funder_display_name":"European Regional Development Fund"}],"funders":[{"id":"https://openalex.org/F4320321697","display_name":"LOEWE Zentrum AdRIA","ror":"https://ror.org/05n911h24"},{"id":"https://openalex.org/F4320335322","display_name":"European Regional Development Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4313435396.pdf","grobid_xml":"https://content.openalex.org/works/W4313435396.grobid-xml"},"referenced_works_count":115,"referenced_works":["https://openalex.org/W634145","https://openalex.org/W1966566790","https://openalex.org/W2051607409","https://openalex.org/W2077806872","https://openalex.org/W2089662726","https://openalex.org/W2101819884","https://openalex.org/W2112866972","https://openalex.org/W2163121678","https://openalex.org/W2295598076","https://openalex.org/W2487770199","https://openalex.org/W2599354622","https://openalex.org/W2607521821","https://openalex.org/W2616996114","https://openalex.org/W2738868428","https://openalex.org/W2739748921","https://openalex.org/W2784246028","https://openalex.org/W2792199860","https://openalex.org/W2799667831","https://openalex.org/W2807496108","https://openalex.org/W2900714093","https://openalex.org/W2903588202","https://openalex.org/W2907978107","https://openalex.org/W2911627187","https://openalex.org/W2911935588","https://openalex.org/W2958468174","https://openalex.org/W2967793520","https://openalex.org/W2969936539","https://openalex.org/W2973542061","https://openalex.org/W2984630731","https://openalex.org/W2988480725","https://openalex.org/W2988729496","https://openalex.org/W2998567984","https://openalex.org/W3000174585","https://openalex.org/W3000210207","https://openalex.org/W3002783982","https://openalex.org/W3004397971","https://openalex.org/W3013122978","https://openalex.org/W3013652391","https://openalex.org/W3022638201","https://openalex.org/W3022744454","https://openalex.org/W3024368698","https://openalex.org/W3024808067","https://openalex.org/W3025233377","https://openalex.org/W3026017474","https://openalex.org/W3028350028","https://openalex.org/W3035504170","https://openalex.org/W3037495086","https://openalex.org/W3037757245","https://openalex.org/W3038395732","https://openalex.org/W3040855982","https://openalex.org/W3045204683","https://openalex.org/W3045445587","https://openalex.org/W3045534893","https://openalex.org/W3046834196","https://openalex.org/W3047406501","https://openalex.org/W3047591854","https://openalex.org/W3047606632","https://openalex.org/W3047875726","https://openalex.org/W3068820327","https://openalex.org/W3079890611","https://openalex.org/W3080782525","https://openalex.org/W3083031547","https://openalex.org/W3084233697","https://openalex.org/W3086775951","https://openalex.org/W3088659404","https://openalex.org/W3091873932","https://openalex.org/W3092184514","https://openalex.org/W3094162974","https://openalex.org/W3107249503","https://openalex.org/W3112280859","https://openalex.org/W3117398788","https://openalex.org/W3117683530","https://openalex.org/W3118914007","https://openalex.org/W3120299959","https://openalex.org/W3127298115","https://openalex.org/W3127658736","https://openalex.org/W3128324886","https://openalex.org/W3128770393","https://openalex.org/W3130186424","https://openalex.org/W3131347421","https://openalex.org/W3134782032","https://openalex.org/W3136172475","https://openalex.org/W3152780591","https://openalex.org/W3157059293","https://openalex.org/W3158556768","https://openalex.org/W3161709284","https://openalex.org/W3162350279","https://openalex.org/W3168505565","https://openalex.org/W3168734664","https://openalex.org/W3170962134","https://openalex.org/W3174059364","https://openalex.org/W3174203890","https://openalex.org/W3181967596","https://openalex.org/W3183930172","https://openalex.org/W3184465100","https://openalex.org/W3186442101","https://openalex.org/W3197360587","https://openalex.org/W3197921256","https://openalex.org/W3198767915","https://openalex.org/W3201172961","https://openalex.org/W3201373283","https://openalex.org/W3201573381","https://openalex.org/W3202323875","https://openalex.org/W3212906182","https://openalex.org/W4200478251","https://openalex.org/W4206822918","https://openalex.org/W4213119456","https://openalex.org/W4226376401","https://openalex.org/W4229838104","https://openalex.org/W4235666733","https://openalex.org/W4243072198","https://openalex.org/W4282969379","https://openalex.org/W6757365985","https://openalex.org/W6773211013","https://openalex.org/W6790565365"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W4240233711","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3111008797","https://openalex.org/W3046823714","https://openalex.org/W2348218441","https://openalex.org/W3021806226","https://openalex.org/W4313435396"],"abstract_inverted_index":{"Heating,":[0],"ventilation,":[1],"and":[2,29,49,107,119,126,145,173,182,210,215],"air":[3],"conditioning":[4],"(HVAC)":[5],"systems":[6,23,82,90],"are":[7,70,189,207],"a":[8,71,86,96],"popular":[9],"research":[10],"topic":[11],"because":[12],"buildings'":[13],"energy":[14],"is":[15,95,116,162],"mostly":[16],"used":[17,171,192],"for":[18,76,85,143],"heating":[19],"and/or":[20],"cooling.":[21],"These":[22],"heavily":[24],"rely":[25],"on":[26,164,186],"sensory":[27],"measurements":[28],"typically":[30],"make":[31],"an":[32],"integral":[33],"part":[34],"of":[35,46,80,89,98,112,200],"the":[36,44,65,78,152,156,159,165,178,198,218],"smart":[37],"building":[38],"concept.":[39],"As":[40],"such,":[41],"they":[42],"require":[43],"implementation":[45],"fault":[47],"detection":[48],"diagnosis":[50],"(FDD)":[51],"methodologies,":[52,123],"which":[53,168,188],"should":[54],"assist":[55],"users":[56],"in":[57,91,100,133,148,177,193],"maintaining":[58],"comfort":[59],"while":[60,203],"consuming":[61],"minimal":[62],"energy.":[63],"Despite":[64],"fact":[66],"that":[67,129],"FDD":[68,122,157,183,205],"approaches":[69,125,206],"well-researched":[72],"subject,":[73],"not":[74],"just":[75],"improving":[77],"operation":[79],"HVAC":[81,134,195],"but":[83],"also":[84,208],"wider":[87],"range":[88],"industrial":[92],"processes,":[93],"there":[94],"lack":[97],"application":[99],"commercial":[101],"buildings":[102],"due":[103],"to":[104,117,139,212],"their":[105],"complexity":[106],"low":[108],"transferability.":[109],"The":[110],"aim":[111],"this":[113,149],"review":[114],"paper":[115],"present":[118],"systematize":[120],"cutting-edge":[121],"encompassing":[124],"special":[127],"techniques":[128,176,181],"can":[130],"be":[131],"applied":[132],"systems,":[135],"as":[136,138],"well":[137],"provide":[140],"best-practice":[141],"heuristics":[142],"researchers":[144],"solution":[146],"developers":[147],"domain.":[150],"While":[151],"literature":[153],"analysis":[154],"targets":[155],"perspective,":[158],"main":[160],"focus":[161],"put":[163],"data-driven":[166],"approach,":[167],"covers":[169],"commonly":[170,191],"models":[172],"data":[174],"pre-processing":[175],"field.":[179],"Data-driven":[180],"solutions":[184],"based":[185],"them,":[187],"most":[190],"recent":[194],"research,":[196],"form":[197],"backbone":[199],"our":[201],"study,":[202],"alternative":[204],"presented":[209],"classified":[211],"properly":[213],"contextualize":[214],"round":[216],"out":[217],"review.":[219]},"counts_by_year":[{"year":2026,"cited_by_count":22},{"year":2025,"cited_by_count":26},{"year":2024,"cited_by_count":12},{"year":2023,"cited_by_count":10}],"updated_date":"2026-08-11T07:18:39.950985","created_date":"2025-10-10T00:00:00"}
