{"id":"https://openalex.org/W4311014172","doi":"https://doi.org/10.3390/s22239312","title":"Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments","display_name":"Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments","publication_year":2022,"publication_date":"2022-11-29","ids":{"openalex":"https://openalex.org/W4311014172","doi":"https://doi.org/10.3390/s22239312","pmid":"https://pubmed.ncbi.nlm.nih.gov/36502014"},"language":"en","primary_location":{"id":"doi:10.3390/s22239312","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22239312","pdf_url":"https://www.mdpi.com/1424-8220/22/23/9312/pdf?version=1669857987","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/22/23/9312/pdf?version=1669857987","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075108258","display_name":"Anna Trych-Wildner","orcid":"https://orcid.org/0000-0002-6197-3004"},"institutions":[{"id":"https://openalex.org/I4210142792","display_name":"Central Office of Measures","ror":"https://ror.org/039f8sh24","country_code":"PL","type":"government","lineage":["https://openalex.org/I4210142792"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Anna Trych-Wildner","raw_affiliation_strings":["Central Office of Measures, Time and Length Department, Precise Geometric Measurements Laboratory, Elektoralna 2, 00-139 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-6197-3004","affiliations":[{"raw_affiliation_string":"Central Office of Measures, Time and Length Department, Precise Geometric Measurements Laboratory, Elektoralna 2, 00-139 Warsaw, Poland","institution_ids":["https://openalex.org/I4210142792"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039130246","display_name":"Krzysztof Wildner","orcid":"https://orcid.org/0000-0003-0531-8563"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Krzysztof Wildner","raw_affiliation_strings":["Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0003-0531-8563","affiliations":[{"raw_affiliation_string":"Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Biomedical Engineering, A. Boboli 8, 02-525 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018317992","display_name":"P. Sosinowski","orcid":"https://orcid.org/0000-0002-5415-2734"},"institutions":[{"id":"https://openalex.org/I4210142792","display_name":"Central Office of Measures","ror":"https://ror.org/039f8sh24","country_code":"PL","type":"government","lineage":["https://openalex.org/I4210142792"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Piotr Sosinowski","raw_affiliation_strings":["Central Office of Measures, Time and Length Department, Precise Geometric Measurements Laboratory, Elektoralna 2, 00-139 Warsaw, Poland"],"raw_orcid":"https://orcid.org/0000-0002-5415-2734","affiliations":[{"raw_affiliation_string":"Central Office of Measures, Time and Length Department, Precise Geometric Measurements Laboratory, Elektoralna 2, 00-139 Warsaw, Poland","institution_ids":["https://openalex.org/I4210142792"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5039130246"],"corresponding_institution_ids":["https://openalex.org/I108403487"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.12548728,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"22","issue":"23","first_page":"9312","last_page":"9312"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10638","display_name":"Optical measurement and interference techniques","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7764058113098145},{"id":"https://openalex.org/keywords/roundness","display_name":"Roundness (object)","score":0.7689284086227417},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7419523596763611},{"id":"https://openalex.org/keywords/traceability","display_name":"Traceability","score":0.6392769813537598},{"id":"https://openalex.org/keywords/measuring-instrument","display_name":"Measuring instrument","score":0.5353975892066956},{"id":"https://openalex.org/keywords/interferometry","display_name":"Interferometry","score":0.5128467679023743},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.49300476908683777},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.4530104100704193},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.434261679649353},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.41850197315216064},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3475038409233093},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.3004973530769348},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.17303383350372314},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16001349687576294},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.13976263999938965}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7764058113098145},{"id":"https://openalex.org/C14190554","wikidata":"https://www.wikidata.org/wiki/Q2496761","display_name":"Roundness (object)","level":2,"score":0.7689284086227417},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7419523596763611},{"id":"https://openalex.org/C153876917","wikidata":"https://www.wikidata.org/wiki/Q899704","display_name":"Traceability","level":2,"score":0.6392769813537598},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.5353975892066956},{"id":"https://openalex.org/C166689943","wikidata":"https://www.wikidata.org/wiki/Q850283","display_name":"Interferometry","level":2,"score":0.5128467679023743},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.49300476908683777},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4530104100704193},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.434261679649353},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41850197315216064},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3475038409233093},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3004973530769348},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.17303383350372314},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16001349687576294},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13976263999938965},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005240","descriptor_name":"Feasibility Studies","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012015","descriptor_name":"Reference Standards","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012015","descriptor_name":"Reference Standards","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012015","descriptor_name":"Reference Standards","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s22239312","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22239312","pdf_url":"https://www.mdpi.com/1424-8220/22/23/9312/pdf?version=1669857987","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:36502014","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/36502014","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:a104d3434b2142d880eff6a0e3ffc8c0","is_oa":true,"landing_page_url":"https://doaj.org/article/a104d3434b2142d880eff6a0e3ffc8c0","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 22, Iss 23, p 9312 (2022)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/22/23/9312/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s22239312","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 22; Issue 23; Pages: 9312","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:9741474","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/9741474","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s22239312","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22239312","pdf_url":"https://www.mdpi.com/1424-8220/22/23/9312/pdf?version=1669857987","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G7297522719","display_name":null,"funder_award_id":"18RPT01","funder_id":"https://openalex.org/F4320313458","funder_display_name":"European Association of National Metrology Institutes"}],"funders":[{"id":"https://openalex.org/F4320313458","display_name":"European Association of National Metrology Institutes","ror":"https://ror.org/03csrq586"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4311014172.pdf","grobid_xml":"https://content.openalex.org/works/W4311014172.grobid-xml"},"referenced_works_count":26,"referenced_works":["https://openalex.org/W1966924977","https://openalex.org/W1970137164","https://openalex.org/W1970417756","https://openalex.org/W1973198293","https://openalex.org/W1977261100","https://openalex.org/W1981178191","https://openalex.org/W1988788895","https://openalex.org/W1995487057","https://openalex.org/W2005500757","https://openalex.org/W2022045347","https://openalex.org/W2029869499","https://openalex.org/W2048619313","https://openalex.org/W2053224983","https://openalex.org/W2053675222","https://openalex.org/W2068008268","https://openalex.org/W2077598504","https://openalex.org/W2077740710","https://openalex.org/W2327219220","https://openalex.org/W2435937937","https://openalex.org/W2895791845","https://openalex.org/W2901056234","https://openalex.org/W2999060112","https://openalex.org/W3000981376","https://openalex.org/W3108223381","https://openalex.org/W6649083157","https://openalex.org/W6772966775"],"related_works":["https://openalex.org/W2077453531","https://openalex.org/W3209492875","https://openalex.org/W2011011149","https://openalex.org/W4205643331","https://openalex.org/W2090239554","https://openalex.org/W2058115773","https://openalex.org/W2789727165","https://openalex.org/W2110648983","https://openalex.org/W2376091113","https://openalex.org/W2044230331"],"abstract_inverted_index":{"The":[0,122],"paper":[1],"presents":[2],"experimental":[3,39],"data":[4,110],"that":[5,20],"show":[6],"the":[7,15,38,50,58,64,72,77,81,89,94,109,114,131,147,151,154],"possible":[8,140],"application":[9,65],"of":[10,17,57,66,91,96,103,124,153],"a":[11,67],"piezo":[12,59,68],"actuator":[13,60,69],"in":[14,146],"role":[16],"calibration":[18,56,115,142],"standard":[19],"can":[21],"serve":[22],"as":[23,137,139],"an":[24,53],"alternative":[25],"route":[26],"to":[27,70,75,85,88,135],"currently":[28],"available":[29],"methods":[30],"like":[31],"gauge":[32],"blocks":[33],"or":[34],"flick":[35],"standards.":[36],"First,":[37],"setups":[40],"for":[41,55,80],"interferometric":[42],"and":[43,84,106,113,159],"roundness":[44,73,82],"instruments":[45],"measurements":[46,98,132],"were":[47,61,111,157],"described.":[48],"Next,":[49],"experiments":[51],"using":[52,119],"interferometer":[54],"shown.":[62],"Finally,":[63,150],"calibrate":[71],"instrument,":[74],"state":[76],"correction":[78],"factor":[79],"probe,":[83],"relate":[86],"it":[87],"unit":[90],"metre,":[92],"assuring":[93],"traceability":[95],"future":[97],"was":[99,117,133],"performed.":[100],"Detailed":[101],"procedures":[102,143,156],"simulating":[104],"grooves":[105],"then":[107],"processing":[108],"described":[112],"curve":[116],"obtained":[118],"regression":[120],"analysis.":[121],"estimation":[123],"uncertainty":[125],"provided":[126],"by":[127],"different":[128],"factors":[129],"during":[130],"given":[134],"fulfil":[136],"closely":[138],"real":[141],"taken":[144],"up":[145],"measurement":[148],"laboratories.":[149],"limitations":[152],"presented":[155,158],"discussed.":[160]},"counts_by_year":[],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
