{"id":"https://openalex.org/W4307765053","doi":"https://doi.org/10.3390/s22218284","title":"Measurement, Validation and Uncertainty of an Experimental Procedure to Characterize the Size-of-Source Effect of Radiation Thermometers, in the Framework of an Industrial Calibration Laboratory","display_name":"Measurement, Validation and Uncertainty of an Experimental Procedure to Characterize the Size-of-Source Effect of Radiation Thermometers, in the Framework of an Industrial Calibration Laboratory","publication_year":2022,"publication_date":"2022-10-28","ids":{"openalex":"https://openalex.org/W4307765053","doi":"https://doi.org/10.3390/s22218284","pmid":"https://pubmed.ncbi.nlm.nih.gov/36365981"},"language":"en","primary_location":{"id":"doi:10.3390/s22218284","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22218284","pdf_url":"https://www.mdpi.com/1424-8220/22/21/8284/pdf?version=1667880013","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/22/21/8284/pdf?version=1667880013","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054096584","display_name":"Javier De Lucas","orcid":"https://orcid.org/0000-0001-9030-6721"},"institutions":[{"id":"https://openalex.org/I4210117279","display_name":"Instituto Nacional de T\u00e9cnica Aeroespacial","ror":"https://ror.org/02m44ak47","country_code":"ES","type":"funder","lineage":["https://openalex.org/I4210117279"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Javier de Lucas","raw_affiliation_strings":["Instituto Nacional de T\u00e9cnica Aeroespacial (INTA), Centro de Metrolog\u00eda y Calibraci\u00f3n, Ctra. de Ajalvir, km 4, 28850 Torrej\u00f3n de Ardoz, Spain"],"raw_orcid":"https://orcid.org/0000-0001-9030-6721","affiliations":[{"raw_affiliation_string":"Instituto Nacional de T\u00e9cnica Aeroespacial (INTA), Centro de Metrolog\u00eda y Calibraci\u00f3n, Ctra. de Ajalvir, km 4, 28850 Torrej\u00f3n de Ardoz, Spain","institution_ids":["https://openalex.org/I4210117279"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5054096584"],"corresponding_institution_ids":["https://openalex.org/I4210117279"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2673},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2673},"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.18618314,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":"22","issue":"21","first_page":"8284","last_page":"8284"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/traceability","display_name":"Traceability","score":0.9209789633750916},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.8152346611022949},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.7706983089447021},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.6186654567718506},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.4464270770549774},{"id":"https://openalex.org/keywords/uncertainty-analysis","display_name":"Uncertainty analysis","score":0.44065189361572266},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.43326759338378906},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3850955069065094},{"id":"https://openalex.org/keywords/process-engineering","display_name":"Process engineering","score":0.3355591893196106},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.27391472458839417},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.259857177734375},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.16150933504104614},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.15766236186027527},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.15444669127464294},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.13684824109077454}],"concepts":[{"id":"https://openalex.org/C153876917","wikidata":"https://www.wikidata.org/wiki/Q899704","display_name":"Traceability","level":2,"score":0.9209789633750916},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.8152346611022949},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.7706983089447021},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.6186654567718506},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4464270770549774},{"id":"https://openalex.org/C177803969","wikidata":"https://www.wikidata.org/wiki/Q29205","display_name":"Uncertainty analysis","level":2,"score":0.44065189361572266},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43326759338378906},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3850955069065094},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3355591893196106},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.27391472458839417},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.259857177734375},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.16150933504104614},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.15766236186027527},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15444669127464294},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13684824109077454},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.0},{"id":"https://openalex.org/C202444582","wikidata":"https://www.wikidata.org/wiki/Q837863","display_name":"Pure mathematics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007753","descriptor_name":"Laboratories","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013821","descriptor_name":"Thermometers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013821","descriptor_name":"Thermometers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D013821","descriptor_name":"Thermometers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D035501","descriptor_name":"Uncertainty","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062125","descriptor_name":"Thermometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D062125","descriptor_name":"Thermometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D062125","descriptor_name":"Thermometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":5,"locations":[{"id":"doi:10.3390/s22218284","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22218284","pdf_url":"https://www.mdpi.com/1424-8220/22/21/8284/pdf?version=1667880013","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:36365981","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/36365981","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:9658027","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/9658027","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"},{"id":"pmh:oai:doaj.org/article:d693c2ee09d7483ab9894b13cf3500a9","is_oa":true,"landing_page_url":"https://doaj.org/article/d693c2ee09d7483ab9894b13cf3500a9","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 22, Iss 21, p 8284 (2022)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/22/21/8284/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s22218284","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 22; Issue 21; Pages: 8284","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s22218284","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22218284","pdf_url":"https://www.mdpi.com/1424-8220/22/21/8284/pdf?version=1667880013","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.6299999952316284}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4307765053.pdf"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W425819358","https://openalex.org/W1486736496","https://openalex.org/W1969655615","https://openalex.org/W1977828590","https://openalex.org/W1995794191","https://openalex.org/W2016708276","https://openalex.org/W2021802512","https://openalex.org/W2049725230","https://openalex.org/W2055362296","https://openalex.org/W2072463324","https://openalex.org/W2083715077","https://openalex.org/W2210244997","https://openalex.org/W2566810736","https://openalex.org/W2962934233"],"related_works":["https://openalex.org/W2077453531","https://openalex.org/W3209492875","https://openalex.org/W2011011149","https://openalex.org/W4381747133","https://openalex.org/W1670618853","https://openalex.org/W4205643331","https://openalex.org/W3130844878","https://openalex.org/W581140221","https://openalex.org/W4233192264","https://openalex.org/W2227715107"],"abstract_inverted_index":{"An":[0],"experimental":[1],"procedure":[2,41,79],"for":[3],"characterizing":[4],"the":[5,15,20,27,47,57,63,95],"size-of-source":[6],"effect":[7,13],"(SSE)":[8],"is":[9,14],"proposed.":[10],"Such":[11],"an":[12],"cause":[16],"of":[17,19,34,53,65,72,76],"one":[18],"main":[21],"influence":[22],"variables":[23],"generating":[24],"uncertainty":[25,43],"in":[26,30,46,51,67,89,94],"measurement,":[28],"both":[29],"calibration":[31,92],"and":[32,42,69,74],"use,":[33],"direct":[35],"reading":[36],"radiation":[37,90],"thermometers":[38],"(RT).":[39],"The":[40],"calculation":[44],"described":[45],"paper":[48],"are":[49,98],"aligned":[50],"terms":[52],"metrological":[54],"traceability,":[55],"with":[56,80],"requirements":[58],"generally":[59],"imposed":[60],"to":[61],"ensure":[62],"accuracy":[64],"measurements":[66],"industry":[68],"science.":[70],"Results":[71],"application":[73],"validation":[75],"this":[77],"particular":[78],"equipment,":[81],"including":[82],"black":[83],"body":[84],"(BB)":[85],"sources":[86],"normally":[87],"used":[88],"thermometry":[91],"laboratories":[93],"industrial":[96],"field,":[97],"shown.":[99]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-08-11T07:18:39.950985","created_date":"2025-10-10T00:00:00"}
