{"id":"https://openalex.org/W4280558223","doi":"https://doi.org/10.3390/s22103769","title":"Comparison of Three Prototypes of PPG Sensors for Continual Real-Time Measurement in Weak Magnetic Field","display_name":"Comparison of Three Prototypes of PPG Sensors for Continual Real-Time Measurement in Weak Magnetic Field","publication_year":2022,"publication_date":"2022-05-16","ids":{"openalex":"https://openalex.org/W4280558223","doi":"https://doi.org/10.3390/s22103769","pmid":"https://pubmed.ncbi.nlm.nih.gov/35632179"},"language":"en","primary_location":{"id":"doi:10.3390/s22103769","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22103769","pdf_url":"https://www.mdpi.com/1424-8220/22/10/3769/pdf?version=1652687358","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/22/10/3769/pdf?version=1652687358","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014980885","display_name":"Ji\u0159\u00ed P\u0159ibil","orcid":"https://orcid.org/0000-0002-7488-1643"},"institutions":[{"id":"https://openalex.org/I207624831","display_name":"Slovak Academy of Sciences","ror":"https://ror.org/03h7qq074","country_code":"SK","type":"government","lineage":["https://openalex.org/I207624831"]},{"id":"https://openalex.org/I4210101454","display_name":"Institute of Measurement Science of the Slovak Academy of Sciences","ror":"https://ror.org/00kmnqa46","country_code":"SK","type":"facility","lineage":["https://openalex.org/I207624831","https://openalex.org/I4210101454"]}],"countries":["SK"],"is_corresponding":true,"raw_author_name":"Ji\u0159\u00ed P\u0159ibil","raw_affiliation_strings":["Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia"],"raw_orcid":"https://orcid.org/0000-0002-7488-1643","affiliations":[{"raw_affiliation_string":"Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia","institution_ids":["https://openalex.org/I4210101454","https://openalex.org/I207624831"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062127825","display_name":"Anna P\u0159ibilov\u00e1","orcid":"https://orcid.org/0000-0002-5107-2552"},"institutions":[{"id":"https://openalex.org/I207624831","display_name":"Slovak Academy of Sciences","ror":"https://ror.org/03h7qq074","country_code":"SK","type":"government","lineage":["https://openalex.org/I207624831"]},{"id":"https://openalex.org/I4210101454","display_name":"Institute of Measurement Science of the Slovak Academy of Sciences","ror":"https://ror.org/00kmnqa46","country_code":"SK","type":"facility","lineage":["https://openalex.org/I207624831","https://openalex.org/I4210101454"]}],"countries":["SK"],"is_corresponding":false,"raw_author_name":"Anna P\u0159ibilov\u00e1","raw_affiliation_strings":["Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia"],"raw_orcid":"https://orcid.org/0000-0002-5107-2552","affiliations":[{"raw_affiliation_string":"Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia","institution_ids":["https://openalex.org/I4210101454","https://openalex.org/I207624831"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045093221","display_name":"Ivan Frollo","orcid":"https://orcid.org/0000-0002-8976-3308"},"institutions":[{"id":"https://openalex.org/I207624831","display_name":"Slovak Academy of Sciences","ror":"https://ror.org/03h7qq074","country_code":"SK","type":"government","lineage":["https://openalex.org/I207624831"]},{"id":"https://openalex.org/I4210101454","display_name":"Institute of Measurement Science of the Slovak Academy of Sciences","ror":"https://ror.org/00kmnqa46","country_code":"SK","type":"facility","lineage":["https://openalex.org/I207624831","https://openalex.org/I4210101454"]}],"countries":["SK"],"is_corresponding":false,"raw_author_name":"Ivan Frollo","raw_affiliation_strings":["Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Measurement Science, Slovak Academy of Sciences, 841 04 Bratislava, Slovakia","institution_ids":["https://openalex.org/I4210101454","https://openalex.org/I207624831"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5014980885"],"corresponding_institution_ids":["https://openalex.org/I207624831","https://openalex.org/I4210101454"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":0.7356,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.64971853,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"22","issue":"10","first_page":"3769","last_page":"3769"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9975000023841858,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.7763941884040833},{"id":"https://openalex.org/keywords/scanner","display_name":"Scanner","score":0.7375293970108032},{"id":"https://openalex.org/keywords/bluetooth","display_name":"Bluetooth","score":0.6262011528015137},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5441317558288574},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49375995993614197},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3474726676940918},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3306651711463928},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3300933837890625},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.30568501353263855},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29944321513175964},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.23861271142959595}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.7763941884040833},{"id":"https://openalex.org/C2779751349","wikidata":"https://www.wikidata.org/wiki/Q1474480","display_name":"Scanner","level":2,"score":0.7375293970108032},{"id":"https://openalex.org/C546215728","wikidata":"https://www.wikidata.org/wiki/Q39531","display_name":"Bluetooth","level":3,"score":0.6262011528015137},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5441317558288574},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49375995993614197},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3474726676940918},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3306651711463928},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3300933837890625},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.30568501353263855},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29944321513175964},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.23861271142959595},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D060526","descriptor_name":"Magnetic Fields","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s22103769","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22103769","pdf_url":"https://www.mdpi.com/1424-8220/22/10/3769/pdf?version=1652687358","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:35632179","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/35632179","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:e4447bec12a541d3892c079363ca2081","is_oa":true,"landing_page_url":"https://doaj.org/article/e4447bec12a541d3892c079363ca2081","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 22, Iss 10, p 3769 (2022)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/22/10/3769/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s22103769","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 22; Issue 10; Pages: 3769","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:9144130","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/9144130","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s22103769","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22103769","pdf_url":"https://www.mdpi.com/1424-8220/22/10/3769/pdf?version=1652687358","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2286379645","display_name":"Personalizovan\u00e1 optimaliz\u00e1cia resynchroniza\u010dnej lie\u010dby srdcov\u00e9ho zlyh\u00e1vania na z\u00e1klade mnohozvodov\u00e9ho merania EKG","funder_award_id":"APVV-19-0531","funder_id":"https://openalex.org/F4320323251","funder_display_name":"Agent\u00fara na Podporu V\u00fdskumu a V\u00fdvoja"},{"id":"https://openalex.org/G7319534556","display_name":null,"funder_award_id":"VEGA2/0003/20","funder_id":"https://openalex.org/F4320323251","funder_display_name":"Agent\u00fara na Podporu V\u00fdskumu a V\u00fdvoja"}],"funders":[{"id":"https://openalex.org/F4320323251","display_name":"Agent\u00fara na Podporu V\u00fdskumu a V\u00fdvoja","ror":"https://ror.org/037nx0e70"}],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4280558223.pdf"},"referenced_works_count":21,"referenced_works":["https://openalex.org/W2083872334","https://openalex.org/W2122022287","https://openalex.org/W2565357947","https://openalex.org/W2793412197","https://openalex.org/W2890046404","https://openalex.org/W2898689085","https://openalex.org/W2913284730","https://openalex.org/W2917470622","https://openalex.org/W2936956228","https://openalex.org/W2973178301","https://openalex.org/W2998942412","https://openalex.org/W3112178568","https://openalex.org/W3165524267","https://openalex.org/W3186366455","https://openalex.org/W3205817727","https://openalex.org/W3211643653","https://openalex.org/W3212538028","https://openalex.org/W3212825552","https://openalex.org/W4205499424","https://openalex.org/W4221126767","https://openalex.org/W4233173939"],"related_works":["https://openalex.org/W2913415010","https://openalex.org/W2020243337","https://openalex.org/W2963832109","https://openalex.org/W2353358273","https://openalex.org/W2344657927","https://openalex.org/W2576058892","https://openalex.org/W2782127508","https://openalex.org/W2533410499","https://openalex.org/W1912582243","https://openalex.org/W3208269919"],"abstract_inverted_index":{"This":[0],"paper":[1],"is":[2],"focused":[3],"on":[4,13,135,193],"investigation":[5,120],"of":[6,10,21,46,67,112,124,127,131,150,164,196],"three":[7,175],"developed":[8],"prototypes":[9,39],"sensors":[11],"based":[12],"the":[14,22,26,31,42,47,68,122,125,128,132,136,140,147,151,182,186,194,197],"photoplethysmography":[15],"(PPG)":[16],"principle":[17],"for":[18,80,168],"continual":[19],"measurement":[20],"PPG":[23,48,81,142,166],"signal":[24,82],"in":[25,41,85,92,173,185],"magnetic":[27,155],"field":[28,154],"environment":[29],"with":[30],"inherent":[32],"radiofrequency":[33],"and":[34,50,58,76,100,109,161,171],"electromagnetic":[35],"disturbance.":[36],"The":[37,64,118],"tested":[38,141],"differ":[40],"used":[43],"optical":[44],"part":[45],"sensor":[49],"their":[51],"working":[52,87],"mode,":[53],"control":[54],"unit,":[55],"power":[56],"supply,":[57],"applied":[59],"Bluetooth":[60],"(BT)":[61],"communication":[62],"methods.":[63],"main":[65],"aim":[66],"current":[69],"work":[70],"was":[71],"motivated":[72],"by":[73,95],"finding":[74],"suitable":[75],"universal":[77],"parameter":[78],"settings":[79],"real-time":[83],"recording":[84],"different":[86],"mode":[88],"conditions.":[89],"Comparative":[90],"measurements":[91],"laboratory":[93],"conditions":[94],"certified":[96],"commercial":[97],"pulse":[98],"oximeter":[99],"blood":[101],"pressure":[102,129],"monitor":[103],"(BPM)":[104],"devices":[105],"show":[106],"good":[107],"stability":[108],"proper":[110,159],"accuracy":[111],"finally":[113,198],"determined":[114],"heart":[115],"rate":[116],"values.":[117],"supplementary":[119],"certifies":[121],"necessity":[123],"placement":[126],"cuff":[130],"BPM":[133],"device":[134],"opposite":[137],"arm":[138],"than":[139],"sensor.":[143],"Measurement":[144],"experiments":[145],"inside":[146],"scanning":[148,187],"area":[149,188],"running":[152],"weak":[153],"resonance":[156],"scanner":[157,200],"verify":[158],"function":[160],"practical":[162],"usability":[163],"sensed":[165],"signals":[167],"further":[169],"processing":[170],"analysis":[172],"all":[174],"prototype":[176],"cases.":[177],"Additional":[178],"testing":[179],"shows":[180],"that":[181],"BT":[183],"transmission":[184],"has":[189],"no":[190],"visible":[191],"influence":[192],"quality":[195],"obtained":[199],"images.":[201]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":1}],"updated_date":"2026-06-22T08:00:12.763002","created_date":"2025-10-10T00:00:00"}
