{"id":"https://openalex.org/W4200479561","doi":"https://doi.org/10.3390/s22010220","title":"Sandwich Integration Technique for the Pressure Sensor Detection of Occlusal Force In Vitro","display_name":"Sandwich Integration Technique for the Pressure Sensor Detection of Occlusal Force In Vitro","publication_year":2021,"publication_date":"2021-12-29","ids":{"openalex":"https://openalex.org/W4200479561","doi":"https://doi.org/10.3390/s22010220","pmid":"https://pubmed.ncbi.nlm.nih.gov/35009761"},"language":"en","primary_location":{"id":"doi:10.3390/s22010220","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22010220","pdf_url":"https://www.mdpi.com/1424-8220/22/1/220/pdf?version=1640775055","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/22/1/220/pdf?version=1640775055","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077668810","display_name":"Jinxia Gao","orcid":"https://orcid.org/0000-0002-5413-4421"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinxia Gao","raw_affiliation_strings":["Department of Prothodontics, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Department of Prothodontics, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Prothodontics, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Department of Prothodontics, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080046377","display_name":"Longjun Liu","orcid":"https://orcid.org/0000-0002-7467-4994"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Longjun Liu","raw_affiliation_strings":["Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051337120","display_name":"Zhiwen Su","orcid":null},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiwen Su","raw_affiliation_strings":["Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Institute of Artificial Intelligence and Robotics, the School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046781428","display_name":"Haitao Wang","orcid":"https://orcid.org/0000-0001-9489-6538"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haitao Wang","raw_affiliation_strings":["Department of Prothodontics, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","Department of Prothodontics, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Prothodontics, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi\u2019an Jiaotong University, Xi\u2019an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Department of Prothodontics, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China","institution_ids":["https://openalex.org/I87445476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5080046377"],"corresponding_institution_ids":["https://openalex.org/I87445476"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2673},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2673},"fwci":0.2178,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.44452566,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"22","issue":"1","first_page":"220","last_page":"220"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10852","display_name":"Temporomandibular Joint Disorders","score":0.9889000058174133,"subfield":{"id":"https://openalex.org/subfields/3603","display_name":"Complementary and Manual Therapy"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11566","display_name":"Laser Applications in Dentistry and Medicine","score":0.9634000062942505,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bite-force-quotient","display_name":"Bite force quotient","score":0.6558358073234558},{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.6149672865867615},{"id":"https://openalex.org/keywords/measurement-device","display_name":"Measurement device","score":0.5983181595802307},{"id":"https://openalex.org/keywords/masticatory-force","display_name":"Masticatory force","score":0.5589959621429443},{"id":"https://openalex.org/keywords/stress","display_name":"Stress (linguistics)","score":0.5508826971054077},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5275099873542786},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5239142179489136},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5057845115661621},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.501990556716919},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4538589119911194},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4496050179004669},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.4471929371356964},{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.4225979447364807},{"id":"https://openalex.org/keywords/biomechanics","display_name":"Biomechanics","score":0.4153580069541931},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.3602738380432129},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.29306018352508545},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.2739703059196472},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.25851041078567505},{"id":"https://openalex.org/keywords/orthodontics","display_name":"Orthodontics","score":0.21784117817878723},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18669730424880981},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.1498892605304718},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10896512866020203},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.07862690091133118}],"concepts":[{"id":"https://openalex.org/C174093841","wikidata":"https://www.wikidata.org/wiki/Q814962","display_name":"Bite force quotient","level":2,"score":0.6558358073234558},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.6149672865867615},{"id":"https://openalex.org/C3019950295","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measurement device","level":2,"score":0.5983181595802307},{"id":"https://openalex.org/C193206974","wikidata":"https://www.wikidata.org/wiki/Q6785539","display_name":"Masticatory force","level":2,"score":0.5589959621429443},{"id":"https://openalex.org/C21036866","wikidata":"https://www.wikidata.org/wiki/Q181767","display_name":"Stress (linguistics)","level":2,"score":0.5508826971054077},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5275099873542786},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5239142179489136},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5057845115661621},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.501990556716919},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4538589119911194},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4496050179004669},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.4471929371356964},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.4225979447364807},{"id":"https://openalex.org/C170700871","wikidata":"https://www.wikidata.org/wiki/Q193378","display_name":"Biomechanics","level":2,"score":0.4153580069541931},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.3602738380432129},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.29306018352508545},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2739703059196472},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.25851041078567505},{"id":"https://openalex.org/C29694066","wikidata":"https://www.wikidata.org/wiki/Q118301","display_name":"Orthodontics","level":1,"score":0.21784117817878723},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18669730424880981},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.1498892605304718},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10896512866020203},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.07862690091133118},{"id":"https://openalex.org/C42407357","wikidata":"https://www.wikidata.org/wiki/Q521","display_name":"Physiology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D001732","descriptor_name":"Bite Force","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001732","descriptor_name":"Bite Force","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001732","descriptor_name":"Bite Force","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013314","descriptor_name":"Stress, Mechanical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013314","descriptor_name":"Stress, Mechanical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D013314","descriptor_name":"Stress, Mechanical","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s22010220","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22010220","pdf_url":"https://www.mdpi.com/1424-8220/22/1/220/pdf?version=1640775055","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:35009761","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/35009761","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:d98e7ce1a26940eba795adf715571e1c","is_oa":true,"landing_page_url":"https://doaj.org/article/d98e7ce1a26940eba795adf715571e1c","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 22, Iss 1, p 220 (2021)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/22/1/220/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s22010220","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 22; Issue 1; Pages: 220","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:8749545","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8749545","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s22010220","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s22010220","pdf_url":"https://www.mdpi.com/1424-8220/22/1/220/pdf?version=1640775055","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4200479561.pdf"},"referenced_works_count":35,"referenced_works":["https://openalex.org/W1034491903","https://openalex.org/W2021522340","https://openalex.org/W2026155567","https://openalex.org/W2027558140","https://openalex.org/W2032178519","https://openalex.org/W2052579038","https://openalex.org/W2054074886","https://openalex.org/W2156378280","https://openalex.org/W2290108649","https://openalex.org/W2464460069","https://openalex.org/W2480947264","https://openalex.org/W2621319643","https://openalex.org/W2764293035","https://openalex.org/W2767065720","https://openalex.org/W2782657386","https://openalex.org/W2793756233","https://openalex.org/W2891873082","https://openalex.org/W2922652962","https://openalex.org/W2972480537","https://openalex.org/W2975450027","https://openalex.org/W2996198356","https://openalex.org/W3000742186","https://openalex.org/W3011811308","https://openalex.org/W3022580245","https://openalex.org/W3042676086","https://openalex.org/W3042688822","https://openalex.org/W3075465768","https://openalex.org/W3092690994","https://openalex.org/W3119796950","https://openalex.org/W3133551780","https://openalex.org/W3153212589","https://openalex.org/W3172671330","https://openalex.org/W4253736094","https://openalex.org/W6745575518","https://openalex.org/W6782403735"],"related_works":["https://openalex.org/W1994900851","https://openalex.org/W2112325206","https://openalex.org/W3129570372","https://openalex.org/W2130760193","https://openalex.org/W2032178519","https://openalex.org/W2103152533","https://openalex.org/W2086132793","https://openalex.org/W2101339049","https://openalex.org/W3175028004","https://openalex.org/W4210453762"],"abstract_inverted_index":{"Bite":[0],"force":[1,26,171],"measurement":[2,46,168],"is":[3,19,36,85,102,110,125,131],"an":[4],"important":[5],"parameter":[6],"when":[7,104,122],"checking":[8],"the":[9,14,31,39,45,50,69,82,94,98,105,123,167],"function":[10],"and":[11,42,47,56,68,72,88,139,145,158],"integrity":[12],"of":[13,33,49,97,134,169],"masticatory":[15],"system,":[16],"whereas":[17],"it":[18,115],"currently":[20],"very":[21],"difficult":[22],"to":[23,37],"measure":[24],"bite":[25,52,170],"during":[27,172],"functional":[28,55],"movement.":[29],"Hence,":[30],"purpose":[32],"this":[34,149],"study":[35],"explore":[38],"potential":[40],"technique":[41,65],"device":[43,109,154],"for":[44,166],"intervention":[48],"continuous":[51],"forces":[53],"on":[54],"dynamic":[57],"occlusal":[58],"condition.":[59],"A":[60],"portable":[61],"biosensor":[62],"by":[63,76,93,156],"sandwich":[64],"was":[66],"designed,":[67],"validity,":[70],"reliability,":[71],"sensitivity":[73],"were":[74],"determined":[75],"mechanical":[77,106,119,152],"pressure":[78,83],"loading":[79],"tests;":[80],"meanwhile,":[81],"signal":[84],"acquired":[86],"by,":[87],"transmitted":[89],"to,":[90],"voltage":[91,140],"changes":[92],"electrical":[95],"measurements":[96],"sensors.":[99],"The":[100,151],"result":[101],"that,":[103],"stress":[107,137],"detection":[108],"thicker":[111],"than":[112,127],"3.5":[113],"mm,":[114,129],"shows":[116],"relatively":[117],"ideal":[118],"properties;":[120],"however,":[121],"thickness":[124],"less":[126],"3.0":[128],"there":[130],"a":[132,143,162],"risk":[133],"cracking.":[135],"Mechanical":[136],"changing":[138],"variation":[141],"had":[142],"regularity":[144],"positive":[146],"relationship":[147],"in":[148],"study.":[150],"stress-measuring":[153],"made":[155],"medical":[157],"industrial":[159],"cross":[160],"has":[161],"good":[163],"application":[164],"prospect":[165],"function.":[173]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2025-10-10T00:00:00"}
