{"id":"https://openalex.org/W4200163235","doi":"https://doi.org/10.3390/s21248197","title":"Remote Arrhythmia Detection for Eldercare in Malaysia","display_name":"Remote Arrhythmia Detection for Eldercare in Malaysia","publication_year":2021,"publication_date":"2021-12-08","ids":{"openalex":"https://openalex.org/W4200163235","doi":"https://doi.org/10.3390/s21248197","pmid":"https://pubmed.ncbi.nlm.nih.gov/34960291"},"language":"en","primary_location":{"id":"doi:10.3390/s21248197","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21248197","pdf_url":"https://www.mdpi.com/1424-8220/21/24/8197/pdf?version=1638959256","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/21/24/8197/pdf?version=1638959256","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072262774","display_name":"Kevin Thomas Chew","orcid":null},"institutions":[{"id":"https://openalex.org/I96413208","display_name":"Swinburne University of Technology Sarawak Campus","ror":"https://ror.org/014cjmc76","country_code":"MY","type":"education","lineage":["https://openalex.org/I57093077","https://openalex.org/I96413208"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Kevin Thomas Chew","raw_affiliation_strings":["Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus, Kuching 93350, Sarawak, Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus, Kuching 93350, Sarawak, Malaysia","institution_ids":["https://openalex.org/I96413208"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069025501","display_name":"Valliappan Raman","orcid":"https://orcid.org/0000-0002-9363-2319"},"institutions":[{"id":"https://openalex.org/I4210128379","display_name":"Orthopaedic Research Group","ror":"https://ror.org/02pfaex92","country_code":"IN","type":"nonprofit","lineage":["https://openalex.org/I4210128379"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Valliappan Raman","raw_affiliation_strings":["Department of AI and DS, Coimbatore Institute of Technology, Coimbatore 641014, Tamil Nadu, India"],"raw_orcid":"https://orcid.org/0000-0002-9363-2319","affiliations":[{"raw_affiliation_string":"Department of AI and DS, Coimbatore Institute of Technology, Coimbatore 641014, Tamil Nadu, India","institution_ids":["https://openalex.org/I4210128379"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5025080623","display_name":"Patrick Then","orcid":"https://orcid.org/0000-0002-6079-2527"},"institutions":[{"id":"https://openalex.org/I96413208","display_name":"Swinburne University of Technology Sarawak Campus","ror":"https://ror.org/014cjmc76","country_code":"MY","type":"education","lineage":["https://openalex.org/I57093077","https://openalex.org/I96413208"]}],"countries":["MY"],"is_corresponding":true,"raw_author_name":"Patrick Hang Hui Then","raw_affiliation_strings":["Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus, Kuching 93350, Sarawak, Malaysia"],"raw_orcid":"https://orcid.org/0000-0002-6079-2527","affiliations":[{"raw_affiliation_string":"Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus, Kuching 93350, Sarawak, Malaysia","institution_ids":["https://openalex.org/I96413208"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5025080623"],"corresponding_institution_ids":["https://openalex.org/I96413208"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":0.3178,"has_fulltext":true,"cited_by_count":4,"citation_normalized_percentile":{"value":0.63717363,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"21","issue":"24","first_page":"8197","last_page":"8197"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9957000017166138,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9926000237464905,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/death-toll","display_name":"Death toll","score":0.6798121333122253},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6179404854774475},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.6172911524772644},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.519376814365387},{"id":"https://openalex.org/keywords/vital-signs","display_name":"Vital signs","score":0.5106576085090637},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.48589223623275757},{"id":"https://openalex.org/keywords/cardiac-arrhythmia","display_name":"Cardiac arrhythmia","score":0.45511725544929504},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4376378357410431},{"id":"https://openalex.org/keywords/medical-emergency","display_name":"Medical emergency","score":0.3915363550186157},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3469048738479614},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.33288073539733887},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.2507593631744385},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.12667709589004517}],"concepts":[{"id":"https://openalex.org/C2991839399","wikidata":"https://www.wikidata.org/wiki/Q96476851","display_name":"Death toll","level":2,"score":0.6798121333122253},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6179404854774475},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.6172911524772644},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.519376814365387},{"id":"https://openalex.org/C2776890885","wikidata":"https://www.wikidata.org/wiki/Q1067560","display_name":"Vital signs","level":2,"score":0.5106576085090637},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.48589223623275757},{"id":"https://openalex.org/C2988455589","wikidata":"https://www.wikidata.org/wiki/Q189331","display_name":"Cardiac arrhythmia","level":3,"score":0.45511725544929504},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4376378357410431},{"id":"https://openalex.org/C545542383","wikidata":"https://www.wikidata.org/wiki/Q2751242","display_name":"Medical emergency","level":1,"score":0.3915363550186157},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3469048738479614},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.33288073539733887},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.2507593631744385},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.12667709589004517},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C2779161974","wikidata":"https://www.wikidata.org/wiki/Q815819","display_name":"Atrial fibrillation","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000368","descriptor_name":"Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000368","descriptor_name":"Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000368","descriptor_name":"Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000368","descriptor_name":"Aged","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D001145","descriptor_name":"Arrhythmias, Cardiac","qualifier_ui":"Q000175","qualifier_name":"diagnosis","is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008296","descriptor_name":"Malaysia","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008296","descriptor_name":"Malaysia","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008296","descriptor_name":"Malaysia","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008296","descriptor_name":"Malaysia","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016208","descriptor_name":"Databases, Factual","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016208","descriptor_name":"Databases, Factual","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016208","descriptor_name":"Databases, Factual","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016208","descriptor_name":"Databases, Factual","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s21248197","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21248197","pdf_url":"https://www.mdpi.com/1424-8220/21/24/8197/pdf?version=1638959256","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:34960291","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/34960291","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:d21e535e77e94a73b3650861dd1444cc","is_oa":true,"landing_page_url":"https://doaj.org/article/d21e535e77e94a73b3650861dd1444cc","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 21, Iss 24, p 8197 (2021)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/21/24/8197/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s21248197","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 21; Issue 24; Pages: 8197","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:8709264","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8709264","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s21248197","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21248197","pdf_url":"https://www.mdpi.com/1424-8220/21/24/8197/pdf?version=1638959256","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.800000011920929,"display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4200163235.pdf","grobid_xml":"https://content.openalex.org/works/W4200163235.grobid-xml"},"referenced_works_count":23,"referenced_works":["https://openalex.org/W1576089372","https://openalex.org/W1994671464","https://openalex.org/W2003931844","https://openalex.org/W2025508891","https://openalex.org/W2089800337","https://openalex.org/W2095409369","https://openalex.org/W2103308415","https://openalex.org/W2107053578","https://openalex.org/W2186910770","https://openalex.org/W2291961022","https://openalex.org/W2402515469","https://openalex.org/W2405782950","https://openalex.org/W2426507626","https://openalex.org/W2476857931","https://openalex.org/W2501597835","https://openalex.org/W2794550444","https://openalex.org/W2795210807","https://openalex.org/W2946495364","https://openalex.org/W2980240687","https://openalex.org/W3022046425","https://openalex.org/W3196099942","https://openalex.org/W6713135856","https://openalex.org/W6776788649"],"related_works":["https://openalex.org/W2053514191","https://openalex.org/W30340901","https://openalex.org/W1660746341","https://openalex.org/W4205307318","https://openalex.org/W2162926135","https://openalex.org/W3005991535","https://openalex.org/W2087901682","https://openalex.org/W4285102294","https://openalex.org/W3948632","https://openalex.org/W2116507356"],"abstract_inverted_index":{"Cardiovascular":[0],"disease":[1],"continues":[2],"to":[3,28,107,124,164],"be":[4],"one":[5],"of":[6,23,34,39,55,70,88,111,128,135],"the":[7,20,29,40,45,50,65,83,126,136,141,155,165,170],"most":[8],"prevalent":[9],"medical":[10],"conditions":[11],"in":[12,97],"modern":[13],"society,":[14],"especially":[15],"among":[16],"elderly":[17,76,98],"citizens.":[18],"As":[19],"leading":[21],"cause":[22],"deaths":[24],"worldwide,":[25],"further":[26],"improvements":[27],"early":[30],"detection":[31,66,96],"and":[32,52,68,85,169],"prevention":[33],"these":[35],"cardiovascular":[36],"diseases":[37],"is":[38,122],"utmost":[41],"importance":[42],"for":[43,63,75,94],"reducing":[44],"death":[46],"toll.":[47],"In":[48,78],"particular,":[49],"remote":[51,90,109],"continuous":[53],"monitoring":[54,92],"vital":[56],"signs":[57],"such":[58],"as":[59],"electrocardiograms":[60],"are":[61],"critical":[62],"improving":[64,73],"rates":[67],"speed":[69],"abnormalities":[71],"while":[72],"accessibility":[74],"individuals.":[77,99],"this":[79],"paper,":[80],"we":[81,101],"consider":[82],"design":[84],"deployment":[86],"characteristics":[87],"a":[89,103,118],"patient":[91],"system":[93,105,137],"arrhythmia":[95],"Thus,":[100],"developed":[102],"scalable":[104],"architecture":[106],"support":[108],"streaming":[110],"ECG":[112,130,174],"signals":[113],"at":[114,140],"near":[115],"real-time.":[116],"Additionally,":[117],"two-phase":[119,156],"classification":[120,131,157],"scheme":[121,158],"proposed":[123],"improve":[125],"performance":[127,161],"existing":[129],"algorithms.":[132],"A":[133],"prototype":[134],"was":[138],"deployed":[139],"Sarawak":[142],"General":[143],"Hospital,":[144],"remotely":[145,171],"collecting":[146],"data":[147],"from":[148],"27":[149],"unique":[150],"patients.":[151],"Evaluations":[152],"indicate":[153],"that":[154],"improves":[159],"algorithm":[160],"when":[162],"applied":[163],"MIT-BIH":[166],"Arrhythmia":[167],"Database":[168],"collected":[172],"single-lead":[173],"recordings.":[175]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1}],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-10-10T00:00:00"}
