{"id":"https://openalex.org/W3210459841","doi":"https://doi.org/10.3390/s21216957","title":"Performance Assessment of a Commercial Continuous-Wave Near-Infrared Spectroscopy Tissue Oximeter for Suitability for Use in an International, Multi-Center Clinical Trial","display_name":"Performance Assessment of a Commercial Continuous-Wave Near-Infrared Spectroscopy Tissue Oximeter for Suitability for Use in an International, Multi-Center Clinical Trial","publication_year":2021,"publication_date":"2021-10-20","ids":{"openalex":"https://openalex.org/W3210459841","doi":"https://doi.org/10.3390/s21216957","mag":"3210459841","pmid":"https://pubmed.ncbi.nlm.nih.gov/34770264"},"language":"en","primary_location":{"id":"doi:10.3390/s21216957","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21216957","pdf_url":"https://www.mdpi.com/1424-8220/21/21/6957/pdf?version=1634814319","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/21/21/6957/pdf?version=1634814319","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5011141818","display_name":"Lorenzo Cortese","orcid":"https://orcid.org/0000-0001-9258-0863"},"institutions":[{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Lorenzo Cortese","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain"],"raw_orcid":"https://orcid.org/0000-0001-9258-0863","affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076059302","display_name":"Marta Zanoletti","orcid":"https://orcid.org/0000-0003-4724-7273"},"institutions":[{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Marta Zanoletti","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103177844","display_name":"Umut Karadeniz","orcid":"https://orcid.org/0000-0001-9085-1527"},"institutions":[{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Umut Karadeniz","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035068349","display_name":"Marco Pagliazzi","orcid":"https://orcid.org/0000-0003-2469-9015"},"institutions":[{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Marco Pagliazzi","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072142517","display_name":"M. Atif Yaqub","orcid":"https://orcid.org/0000-0002-9885-7891"},"institutions":[{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"M. Atif Yaqub","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010824000","display_name":"David R. Busch","orcid":"https://orcid.org/0000-0002-9488-944X"},"institutions":[{"id":"https://openalex.org/I867280407","display_name":"The University of Texas Southwestern Medical Center","ror":"https://ror.org/05byvp690","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I867280407"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"David R. Busch","raw_affiliation_strings":["Department of Anesthesiology and Pain Management and Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA"],"raw_orcid":"https://orcid.org/0000-0002-9488-944X","affiliations":[{"raw_affiliation_string":"Department of Anesthesiology and Pain Management and Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA","institution_ids":["https://openalex.org/I867280407"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054738986","display_name":"Jaume Mesquida","orcid":"https://orcid.org/0000-0003-3670-5021"},"institutions":[{"id":"https://openalex.org/I4210115578","display_name":"Corporaci\u00f3 Sanit\u00e0ria Parc Taul\u00ed","ror":"https://ror.org/02pg81z63","country_code":"ES","type":"other","lineage":["https://openalex.org/I4210115578"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jaume Mesquida","raw_affiliation_strings":["\u00c0rea de Cr\u00edtics, Parc Taul\u00ed Hospital Universitari, 08208 Sabadell, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"\u00c0rea de Cr\u00edtics, Parc Taul\u00ed Hospital Universitari, 08208 Sabadell, Spain","institution_ids":["https://openalex.org/I4210115578"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032348810","display_name":"Turgut Durduran","orcid":"https://orcid.org/0000-0001-5838-1027"},"institutions":[{"id":"https://openalex.org/I11932220","display_name":"Instituci\u00f3 Catalana de Recerca i Estudis Avan\u00e7ats","ror":"https://ror.org/0371hy230","country_code":"ES","type":"nonprofit","lineage":["https://openalex.org/I11932220"]},{"id":"https://openalex.org/I179630473","display_name":"Institute of Photonic Sciences","ror":"https://ror.org/03g5ew477","country_code":"ES","type":"facility","lineage":["https://openalex.org/I179630473","https://openalex.org/I4210132884","https://openalex.org/I4387153040","https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Turgut Durduran","raw_affiliation_strings":["ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","Instituci\u00f3 Catalana de Recerca i Estudis Avan\u00e7ats (ICREA), 08015 Barcelona, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ICFO-Institut de Ci\u00e8ncies Fot\u00f2niques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain","institution_ids":["https://openalex.org/I179630473"]},{"raw_affiliation_string":"Instituci\u00f3 Catalana de Recerca i Estudis Avan\u00e7ats (ICREA), 08015 Barcelona, Spain","institution_ids":["https://openalex.org/I11932220"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5011141818"],"corresponding_institution_ids":["https://openalex.org/I179630473"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2673},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2673},"fwci":2.0265,"has_fulltext":true,"cited_by_count":26,"citation_normalized_percentile":{"value":0.86982988,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"21","issue":"21","first_page":"6957","last_page":"6957"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reproducibility","display_name":"Reproducibility","score":0.8568515777587891},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.6769514083862305},{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.6114644408226013},{"id":"https://openalex.org/keywords/forearm","display_name":"Forearm","score":0.4925902485847473},{"id":"https://openalex.org/keywords/near-infrared-spectroscopy","display_name":"Near-infrared spectroscopy","score":0.4705484211444855},{"id":"https://openalex.org/keywords/medical-device","display_name":"Medical device","score":0.42653340101242065},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.39301639795303345},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3828967213630676},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.2391623854637146},{"id":"https://openalex.org/keywords/nuclear-medicine","display_name":"Nuclear medicine","score":0.2346743941307068},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1639796793460846},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.1501699686050415},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.12505576014518738},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08396464586257935}],"concepts":[{"id":"https://openalex.org/C9893847","wikidata":"https://www.wikidata.org/wiki/Q1425625","display_name":"Reproducibility","level":2,"score":0.8568515777587891},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.6769514083862305},{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.6114644408226013},{"id":"https://openalex.org/C2780214079","wikidata":"https://www.wikidata.org/wiki/Q228537","display_name":"Forearm","level":2,"score":0.4925902485847473},{"id":"https://openalex.org/C43571822","wikidata":"https://www.wikidata.org/wiki/Q599037","display_name":"Near-infrared spectroscopy","level":2,"score":0.4705484211444855},{"id":"https://openalex.org/C3020535179","wikidata":"https://www.wikidata.org/wiki/Q6554101","display_name":"Medical device","level":2,"score":0.42653340101242065},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.39301639795303345},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3828967213630676},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.2391623854637146},{"id":"https://openalex.org/C2989005","wikidata":"https://www.wikidata.org/wiki/Q214963","display_name":"Nuclear medicine","level":1,"score":0.2346743941307068},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1639796793460846},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.1501699686050415},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.12505576014518738},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08396464586257935}],"mesh":[{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010101","descriptor_name":"Oxygen Consumption","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010101","descriptor_name":"Oxygen Consumption","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010101","descriptor_name":"Oxygen Consumption","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019265","descriptor_name":"Spectroscopy, Near-Infrared","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019265","descriptor_name":"Spectroscopy, Near-Infrared","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019265","descriptor_name":"Spectroscopy, Near-Infrared","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":5,"locations":[{"id":"doi:10.3390/s21216957","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21216957","pdf_url":"https://www.mdpi.com/1424-8220/21/21/6957/pdf?version=1634814319","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:34770264","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/34770264","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:210dd73945f74c09bb0a9173eba1f195","is_oa":true,"landing_page_url":"https://doaj.org/article/210dd73945f74c09bb0a9173eba1f195","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 21, Iss 21, p 6957 (2021)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/21/21/6957/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s21216957","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 21; Issue 21; Pages: 6957","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:8587042","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/8587042","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s21216957","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s21216957","pdf_url":"https://www.mdpi.com/1424-8220/21/21/6957/pdf?version=1634814319","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/17","score":0.41999998688697815,"display_name":"Partnerships for the goals"}],"awards":[{"id":"https://openalex.org/G2509333814","display_name":null,"funder_award_id":"RIS3CAT-001-P-001682 CECH","funder_id":"https://openalex.org/F4320321505","funder_display_name":"Generalitat de Catalunya"},{"id":"https://openalex.org/G4653004460","display_name":null,"funder_award_id":"PID2019-106481RB-C31/10.13039/501100011033","funder_id":"https://openalex.org/F4320335598","funder_display_name":"Agencia Estatal de Investigaci\u00f3n"},{"id":"https://openalex.org/G5085471144","display_name":null,"funder_award_id":"AGAUR-2017-SGR-1380","funder_id":"https://openalex.org/F4320321505","funder_display_name":"Generalitat de Catalunya"},{"id":"https://openalex.org/G5355214168","display_name":null,"funder_award_id":"CERCA, AGAUR-2017-SGR-1380, RIS3CAT-001-P-001682 CECH","funder_id":"https://openalex.org/F4320321505","funder_display_name":"Generalitat de Catalunya"},{"id":"https://openalex.org/G5858299311","display_name":null,"funder_award_id":"PHOTOMETABO, PID2019-106481RB-C31/10.13039/501100011033","funder_id":"https://openalex.org/F4320335598","funder_display_name":"Agencia Estatal de Investigaci\u00f3n"}],"funders":[{"id":"https://openalex.org/F4320321505","display_name":"Generalitat de Catalunya","ror":"https://ror.org/01bg62x04"},{"id":"https://openalex.org/F4320335598","display_name":"Agencia Estatal de Investigaci\u00f3n","ror":null}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3210459841.pdf","grobid_xml":"https://content.openalex.org/works/W3210459841.grobid-xml"},"referenced_works_count":44,"referenced_works":["https://openalex.org/W10242373","https://openalex.org/W125925698","https://openalex.org/W1566448640","https://openalex.org/W1854903597","https://openalex.org/W1860268468","https://openalex.org/W1965424201","https://openalex.org/W1966267780","https://openalex.org/W1967705433","https://openalex.org/W1978036531","https://openalex.org/W1996324319","https://openalex.org/W2001262493","https://openalex.org/W2007069772","https://openalex.org/W2022390445","https://openalex.org/W2025036436","https://openalex.org/W2025564775","https://openalex.org/W2029158148","https://openalex.org/W2032113873","https://openalex.org/W2034277556","https://openalex.org/W2039932743","https://openalex.org/W2041296095","https://openalex.org/W2060663786","https://openalex.org/W2063461906","https://openalex.org/W2096732105","https://openalex.org/W2116671486","https://openalex.org/W2129158699","https://openalex.org/W2130603606","https://openalex.org/W2134976092","https://openalex.org/W2142975250","https://openalex.org/W2144286520","https://openalex.org/W2148310177","https://openalex.org/W2159108773","https://openalex.org/W2166564467","https://openalex.org/W2404663390","https://openalex.org/W2430490683","https://openalex.org/W2464552791","https://openalex.org/W2487851432","https://openalex.org/W2557093061","https://openalex.org/W2747387711","https://openalex.org/W2772933431","https://openalex.org/W2790356515","https://openalex.org/W2972853731","https://openalex.org/W3133083263","https://openalex.org/W3212105453","https://openalex.org/W6630060650"],"related_works":["https://openalex.org/W2413717610","https://openalex.org/W1973270181","https://openalex.org/W2417696084","https://openalex.org/W2368782778","https://openalex.org/W2087830269","https://openalex.org/W3106281778","https://openalex.org/W4324138256","https://openalex.org/W3134060498","https://openalex.org/W2003643616","https://openalex.org/W638612878"],"abstract_inverted_index":{"Despite":[0],"the":[1,9,12,37,62,71,83,111,135,146,153,172,177,184,187,190],"wide":[2],"range":[3],"of":[4,11,16,29,39,42,87,89,186,189],"clinical":[5,64,192],"and":[6,75,85,94,114,162,227],"research":[7],"applications,":[8],"reliability":[10],"absolute":[13],"oxygenation":[14,198],"measurements":[15,88,151],"continuous":[17,44],"wave":[18,45],"near-infrared":[19,46],"spectroscopy":[20,47],"sensors":[21],"is":[22,142,209],"often":[23],"questioned,":[24],"partially":[25],"due":[26],"to":[27,54,81,145,224],"issues":[28],"standardization.":[30],"In":[31],"this":[32],"study,":[33],"we":[34,181],"have":[35,119,182],"compared":[36],"performances":[38],"13":[40],"units":[41],"a":[43],"device":[48],"(PortaMon,":[49],"Artinis":[50],"Medical":[51],"Systems,":[52],"NL)":[53],"test":[55],"their":[56],"suitability":[57],"for":[58,101,107,230],"being":[59],"used":[60,215],"in":[61,66,76,143,149,159,216],"HEMOCOVID-19":[63,191],"trial":[65],"10":[67],"medical":[68],"centers":[69],"around":[70],"world.":[72],"Detailed":[73],"phantom":[74],"vivo":[77,150],"tests":[78,203],"were":[79,132],"employed":[80],"measure":[82],"precision":[84],"reproducibility":[86,185],"local":[90],"blood":[91],"oxygen":[92],"saturation":[93],"total":[95],"hemoglobin":[96],"concentration":[97],"under":[98],"different":[99,102,105],"conditions:":[100],"devices":[103,124,212],"used,":[104],"operators,":[106],"probe":[108,160],"repositioning":[109],"over":[110,115,204],"same":[112,178],"location,":[113],"time":[116],"(hours/days/months).":[117],"We":[118],"detected":[120],"systematic":[121],"differences":[122,174],"between":[123],"when":[125],"measuring":[126],"phantoms":[127],"(inter-device":[128],"variability,":[129],"<4%),":[130],"which":[131,167],"larger":[133,170],"than":[134,171],"intra-device":[136],"variability":[137,141,147],"(<1%).":[138],"This":[139],"intrinsic":[140,163],"addition":[144],"during":[148,176,200],"on":[152],"forearm":[154,196],"muscle":[155,197],"resulting":[156],"from":[157],"errors":[158],"positioning":[161],"physiological":[164],"noise":[165],"(<9%),":[166],"was":[168],"also":[169],"inter-device":[173,231],"(<3%)":[175],"test.":[179],"Lastly,":[180],"tested":[183],"protocol":[188],"trial;":[193],"that":[194,210],"is,":[195],"monitoring":[199],"vascular":[201],"occlusion":[202],"days.":[205],"Overall,":[206],"our":[207],"conclusion":[208],"these":[211],"can":[213],"be":[214,222],"multi-center":[217],"trials":[218],"but":[219],"care":[220],"must":[221],"taken":[223],"characterize,":[225],"follow-up,":[226],"statistically":[228],"account":[229],"variability.":[232]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
