{"id":"https://openalex.org/W2998358346","doi":"https://doi.org/10.3390/s20010202","title":"An Evaluation of Electromagnetic Exposure While Using Ultra-High Frequency Radiofrequency Identification (UHF RFID) Guns","display_name":"An Evaluation of Electromagnetic Exposure While Using Ultra-High Frequency Radiofrequency Identification (UHF RFID) Guns","publication_year":2019,"publication_date":"2019-12-30","ids":{"openalex":"https://openalex.org/W2998358346","doi":"https://doi.org/10.3390/s20010202","mag":"2998358346","pmid":"https://pubmed.ncbi.nlm.nih.gov/31905869"},"language":"en","primary_location":{"id":"doi:10.3390/s20010202","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s20010202","pdf_url":"https://www.mdpi.com/1424-8220/20/1/202/pdf?version=1577695925","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/20/1/202/pdf?version=1577695925","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013790276","display_name":"Patryk Zradzi\u0144ski","orcid":"https://orcid.org/0000-0001-8094-0761"},"institutions":[{"id":"https://openalex.org/I4210139689","display_name":"Central Institute for Labour Protection","ror":"https://ror.org/03x0yya69","country_code":"PL","type":"facility","lineage":["https://openalex.org/I4210139689"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"Patryk Zradzi\u0144ski","raw_affiliation_strings":["Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland"],"raw_orcid":"https://orcid.org/0000-0001-8094-0761","affiliations":[{"raw_affiliation_string":"Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland","institution_ids":["https://openalex.org/I4210139689"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007999228","display_name":"Jolanta Karpowicz","orcid":"https://orcid.org/0000-0003-2547-2728"},"institutions":[{"id":"https://openalex.org/I4210139689","display_name":"Central Institute for Labour Protection","ror":"https://ror.org/03x0yya69","country_code":"PL","type":"facility","lineage":["https://openalex.org/I4210139689"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Jolanta Karpowicz","raw_affiliation_strings":["Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland"],"raw_orcid":"https://orcid.org/0000-0003-2547-2728","affiliations":[{"raw_affiliation_string":"Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland","institution_ids":["https://openalex.org/I4210139689"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003357209","display_name":"Krzysztof Gryz","orcid":"https://orcid.org/0000-0001-5655-2187"},"institutions":[{"id":"https://openalex.org/I4210139689","display_name":"Central Institute for Labour Protection","ror":"https://ror.org/03x0yya69","country_code":"PL","type":"facility","lineage":["https://openalex.org/I4210139689"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Krzysztof Gryz","raw_affiliation_strings":["Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection\u2014National Research Institute (CIOP-PIB), ul. Czerniakowska 16, 00-701 Warszawa, Poland","institution_ids":["https://openalex.org/I4210139689"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013671538","display_name":"Victoria Ramos","orcid":"https://orcid.org/0000-0002-8776-4489"},"institutions":[{"id":"https://openalex.org/I2801357902","display_name":"Instituto de Salud Carlos III","ror":"https://ror.org/00ca2c886","country_code":"ES","type":"funder","lineage":["https://openalex.org/I2801357902","https://openalex.org/I4387152914"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Victoria Ramos","raw_affiliation_strings":["Telemedicine and e-Health Research Unit, Instituto de Salud Carlos III, 28025 Madrid, Spain"],"raw_orcid":"https://orcid.org/0000-0002-8776-4489","affiliations":[{"raw_affiliation_string":"Telemedicine and e-Health Research Unit, Instituto de Salud Carlos III, 28025 Madrid, Spain","institution_ids":["https://openalex.org/I2801357902"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5013790276"],"corresponding_institution_ids":["https://openalex.org/I4210139689"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":2.9062,"has_fulltext":true,"cited_by_count":13,"citation_normalized_percentile":{"value":0.91389961,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"20","issue":"1","first_page":"202","last_page":"202"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10874","display_name":"Electromagnetic Fields and Biological Effects","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T10874","display_name":"Electromagnetic Fields and Biological Effects","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11851","display_name":"Electromagnetic Compatibility and Measurements","score":0.951200008392334,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultra-high-frequency","display_name":"Ultra high frequency","score":0.8950241804122925},{"id":"https://openalex.org/keywords/torso","display_name":"Torso","score":0.7131191492080688},{"id":"https://openalex.org/keywords/radio-frequency-identification","display_name":"Radio-frequency identification","score":0.7074597477912903},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.43576741218566895},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42705345153808594},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4211472272872925},{"id":"https://openalex.org/keywords/specific-absorption-rate","display_name":"Specific absorption rate","score":0.4206077456474304},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35684734582901},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3412068486213684},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.32433781027793884},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31694215536117554},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.29290708899497986},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.25207072496414185},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.20192554593086243},{"id":"https://openalex.org/keywords/aerospace-engineering","display_name":"Aerospace engineering","score":0.13506272435188293}],"concepts":[{"id":"https://openalex.org/C96122199","wikidata":"https://www.wikidata.org/wiki/Q628096","display_name":"Ultra high frequency","level":2,"score":0.8950241804122925},{"id":"https://openalex.org/C523889960","wikidata":"https://www.wikidata.org/wiki/Q160695","display_name":"Torso","level":2,"score":0.7131191492080688},{"id":"https://openalex.org/C204222849","wikidata":"https://www.wikidata.org/wiki/Q104954","display_name":"Radio-frequency identification","level":2,"score":0.7074597477912903},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.43576741218566895},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42705345153808594},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4211472272872925},{"id":"https://openalex.org/C84237751","wikidata":"https://www.wikidata.org/wiki/Q914138","display_name":"Specific absorption rate","level":3,"score":0.4206077456474304},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35684734582901},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3412068486213684},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.32433781027793884},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31694215536117554},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.29290708899497986},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.25207072496414185},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.20192554593086243},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.13506272435188293},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.0},{"id":"https://openalex.org/C21822782","wikidata":"https://www.wikidata.org/wiki/Q131214","display_name":"Antenna (radio)","level":2,"score":0.0}],"mesh":[],"locations_count":6,"locations":[{"id":"doi:10.3390/s20010202","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s20010202","pdf_url":"https://www.mdpi.com/1424-8220/20/1/202/pdf?version=1577695925","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:31905869","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/31905869","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:dnet:repisalud___::ab244669d746fb4623124305c3867c95","is_oa":true,"landing_page_url":"http://hdl.handle.net/20.500.12105/8915","pdf_url":"http://hdl.handle.net/20.500.12105/8915","source":{"id":"https://openalex.org/S4306402641","display_name":"LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Cient\u00edficas)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4383465926","host_organization_name":"LA Referencia","host_organization_lineage":["https://openalex.org/I4383465926"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:doaj.org/article:4de248fc65f8493da44b6d25efc721b9","is_oa":true,"landing_page_url":"https://doaj.org/article/4de248fc65f8493da44b6d25efc721b9","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 20, Iss 1, p 202 (2019)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/20/1/202/","is_oa":true,"landing_page_url":"http://dx.doi.org/10.3390/s20010202","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:6982864","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/6982864","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s20010202","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s20010202","pdf_url":"https://www.mdpi.com/1424-8220/20/1/202/pdf?version=1577695925","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2998358346.pdf","grobid_xml":"https://content.openalex.org/works/W2998358346.grobid-xml"},"referenced_works_count":15,"referenced_works":["https://openalex.org/W643058322","https://openalex.org/W1567398574","https://openalex.org/W1761287144","https://openalex.org/W1970178718","https://openalex.org/W2013634656","https://openalex.org/W2043723025","https://openalex.org/W2054111692","https://openalex.org/W2151270428","https://openalex.org/W2156209998","https://openalex.org/W2283635835","https://openalex.org/W2409101823","https://openalex.org/W2970447244","https://openalex.org/W4300669342","https://openalex.org/W6633904902","https://openalex.org/W6661310323"],"related_works":["https://openalex.org/W4381953457","https://openalex.org/W4285153716","https://openalex.org/W2673135913","https://openalex.org/W2900806914","https://openalex.org/W2890875378","https://openalex.org/W4236373924","https://openalex.org/W1031946321","https://openalex.org/W2479707740","https://openalex.org/W2288231918","https://openalex.org/W2357525140"],"abstract_inverted_index":{"The":[0,102],"aim":[1],"is":[2],"to":[3,32,39,46,51,90,121,203],"evaluate":[4],"specific":[5],"absorption":[6],"rate":[7],"(SAR)":[8],"values":[9],"from":[10],"exposure":[11,73,106,114,175],"near":[12,76,89],"handheld":[13],"ultra-high":[14],"frequency":[15],"radiofrequency":[16],"identification":[17],"readers":[18],"(UHF":[19],"RFID":[20,42,213],"guns-small":[21],"electronic":[22,186],"devices,":[23],"or":[24,88,99,170],"even":[25,205],"portable":[26],"computers":[27],"with":[28,108,137],"relevant":[29],"accessories-emitting":[30],"up":[31,120],"several":[33],"watts":[34],"of":[35,63,82,95,159,165,185,208],"electromagnetic":[36],"field":[37],"(EMF)":[38],"search":[40],"for":[41,86,111],"sensors":[43],"(tags)":[44],"attached":[45],"marked":[47],"objects),":[48],"in":[49,65,71,156,200],"order":[50],"test":[52],"the":[53,77,83,91,96,133,152,157,160,163,166],"hypothesis":[54],"that":[55],"they":[56],"have":[57],"an":[58,149],"insignificant":[59,224],"environmental":[60],"influence.":[61],"Simulations":[62],"SAR":[64,109,150],"adult":[66],"male":[67],"and":[68,93,162,189],"female":[69],"models":[70],"seven":[72],"scenarios":[74],"(gun":[75],"head,":[78],"arm,":[79],"chest,":[80],"hip/thigh":[81],"operator":[84],"searching":[85],"tags,":[87],"chest":[92],"arm":[94],"scanned":[97,172],"person":[98],"a":[100,138,168,171],"bystander).":[101],"results":[103],"showed":[104],"EMF":[105,225],"compliant":[107],"limits":[110,155,176],"general":[112,153],"public":[113,154],"(ICNIRP/European":[115],"Recommendation":[116],"1999/519/EC)":[117],"at":[118,197,206],"emissions":[119,207],"1":[122,209,217],"W":[123,145,218],"(reading":[124],"range":[125,140],"3.5-11":[126],"m,":[127],"depending":[128],"on":[129],"tag":[130],"sensitivity).":[131],"In":[132],"worst-case":[134],"scenario,":[135],"guns":[136,214],"reading":[139],"exceeding":[141,151],"5":[142],"m":[143],"(>2":[144],"emission)":[146],"may":[147,177,219],"cause":[148],"palm":[158],"user":[161],"torso":[164],"user,":[167],"bystander,":[169],"person;":[173],"occupational":[174],"be":[178,193,220],"exceeded":[179],"when":[180],"emission":[181],">5":[182],"W.":[183,210],"Users":[184],"medical":[187],"implants":[188],"pregnant":[190],"women":[191],"should":[192],"treated":[194],"as":[195,222],"individuals":[196],"particular":[198],"risk":[199],"close":[201],"proximity":[202],"guns,":[204],"Only":[211],"UHF":[212],"emitting":[215],"below":[216],"considered":[221],"environmentally":[223],"sources.":[226]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":3}],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-10-10T00:00:00"}
