{"id":"https://openalex.org/W2897441973","doi":"https://doi.org/10.3390/s18103457","title":"Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood","display_name":"Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood","publication_year":2018,"publication_date":"2018-10-15","ids":{"openalex":"https://openalex.org/W2897441973","doi":"https://doi.org/10.3390/s18103457","mag":"2897441973","pmid":"https://pubmed.ncbi.nlm.nih.gov/30326552"},"language":"en","primary_location":{"id":"doi:10.3390/s18103457","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s18103457","pdf_url":"https://www.mdpi.com/1424-8220/18/10/3457/pdf?version=1539572874","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/18/10/3457/pdf?version=1539572874","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070515499","display_name":"Ohad Yossef Hay","orcid":null},"institutions":[{"id":"https://openalex.org/I124227911","display_name":"Ben-Gurion University of the Negev","ror":"https://ror.org/05tkyf982","country_code":"IL","type":"education","lineage":["https://openalex.org/I124227911"]},{"id":"https://openalex.org/I192238737","display_name":"Jerusalem College of Technology","ror":"https://ror.org/002kenh51","country_code":"IL","type":"education","lineage":["https://openalex.org/I192238737"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Ohad Yossef Hay","raw_affiliation_strings":["Department of Electro-Optical Engineering, Ben-Gurion University of the Negev. 1 Ben-Gurion Blvd, 8410501 Beer Sheva, Israel","Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electro-Optical Engineering, Ben-Gurion University of the Negev. 1 Ben-Gurion Blvd, 8410501 Beer Sheva, Israel","institution_ids":["https://openalex.org/I124227911"]},{"raw_affiliation_string":"Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel","institution_ids":["https://openalex.org/I192238737"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007292663","display_name":"M. Cohen","orcid":null},"institutions":[{"id":"https://openalex.org/I192238737","display_name":"Jerusalem College of Technology","ror":"https://ror.org/002kenh51","country_code":"IL","type":"education","lineage":["https://openalex.org/I192238737"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Meir Cohen","raw_affiliation_strings":["Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel","institution_ids":["https://openalex.org/I192238737"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032430288","display_name":"Itamar Nitzan","orcid":"https://orcid.org/0000-0003-1016-815X"},"institutions":[{"id":"https://openalex.org/I2801962034","display_name":"Shaare Zedek Medical Center","ror":"https://ror.org/04d0szq68","country_code":"IL","type":"healthcare","lineage":["https://openalex.org/I2801962034"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Itamar Nitzan","raw_affiliation_strings":["Department of Neonatology, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Neonatology, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel","institution_ids":["https://openalex.org/I2801962034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057560701","display_name":"Yair Kasirer","orcid":"https://orcid.org/0000-0003-2227-1074"},"institutions":[{"id":"https://openalex.org/I2801962034","display_name":"Shaare Zedek Medical Center","ror":"https://ror.org/04d0szq68","country_code":"IL","type":"healthcare","lineage":["https://openalex.org/I2801962034"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Yair Kasirer","raw_affiliation_strings":["Department of Neonatology, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Neonatology, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel","institution_ids":["https://openalex.org/I2801962034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073715083","display_name":"Sarit Shahroor-Karni","orcid":null},"institutions":[{"id":"https://openalex.org/I2801962034","display_name":"Shaare Zedek Medical Center","ror":"https://ror.org/04d0szq68","country_code":"IL","type":"healthcare","lineage":["https://openalex.org/I2801962034"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Sarit Shahroor-karni","raw_affiliation_strings":["Pediatric Intensive Care Unit, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pediatric Intensive Care Unit, Shaare Zedek Medical Center, Shmuel Bait St 12, 9103102 Jerusalem, Israel","institution_ids":["https://openalex.org/I2801962034"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045386438","display_name":"Yitzhak Yitzhaky","orcid":"https://orcid.org/0000-0002-4974-9683"},"institutions":[{"id":"https://openalex.org/I124227911","display_name":"Ben-Gurion University of the Negev","ror":"https://ror.org/05tkyf982","country_code":"IL","type":"education","lineage":["https://openalex.org/I124227911"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Yitzhak Yitzhaky","raw_affiliation_strings":["Department of Electro-Optical Engineering, Ben-Gurion University of the Negev. 1 Ben-Gurion Blvd, 8410501 Beer Sheva, Israel"],"raw_orcid":"https://orcid.org/0000-0002-4974-9683","affiliations":[{"raw_affiliation_string":"Department of Electro-Optical Engineering, Ben-Gurion University of the Negev. 1 Ben-Gurion Blvd, 8410501 Beer Sheva, Israel","institution_ids":["https://openalex.org/I124227911"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084961243","display_name":"Shlomo Engelberg","orcid":"https://orcid.org/0000-0001-8190-1860"},"institutions":[{"id":"https://openalex.org/I192238737","display_name":"Jerusalem College of Technology","ror":"https://ror.org/002kenh51","country_code":"IL","type":"education","lineage":["https://openalex.org/I192238737"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Shlomo Engelberg","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel"],"raw_orcid":"https://orcid.org/0000-0001-8190-1860","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel","institution_ids":["https://openalex.org/I192238737"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089842884","display_name":"Meir Nitzan","orcid":"https://orcid.org/0000-0001-9555-1435"},"institutions":[{"id":"https://openalex.org/I192238737","display_name":"Jerusalem College of Technology","ror":"https://ror.org/002kenh51","country_code":"IL","type":"education","lineage":["https://openalex.org/I192238737"]}],"countries":["IL"],"is_corresponding":true,"raw_author_name":"Meir Nitzan","raw_affiliation_strings":["Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Physics/Electro-Optics Engineering, Jerusalem College of Technology, 21 Havaad Haleumi St., 91160 Jerusalem, Israel","institution_ids":["https://openalex.org/I192238737"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":["https://openalex.org/A5089842884"],"corresponding_institution_ids":["https://openalex.org/I192238737"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":2400,"currency":"CHF","value_usd":2598},"fwci":1.4486,"has_fulltext":true,"cited_by_count":39,"citation_normalized_percentile":{"value":0.80984898,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"18","issue":"10","first_page":"3457","last_page":"3457"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11324","display_name":"Spectroscopy Techniques in Biomedical and Chemical Research","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse-oximetry","display_name":"Pulse oximetry","score":0.8397222757339478},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6618080139160156},{"id":"https://openalex.org/keywords/infrared","display_name":"Infrared","score":0.578977108001709},{"id":"https://openalex.org/keywords/wavelength","display_name":"Wavelength","score":0.5529239773750305},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.5247799754142761},{"id":"https://openalex.org/keywords/arterial-blood","display_name":"Arterial blood","score":0.5183088183403015},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.491508811712265},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4731394350528717},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.412007212638855},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.32498353719711304},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3039242625236511},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.24141603708267212},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1796671450138092},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12055149674415588},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.07510605454444885}],"concepts":[{"id":"https://openalex.org/C2780124106","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Pulse oximetry","level":2,"score":0.8397222757339478},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6618080139160156},{"id":"https://openalex.org/C158355884","wikidata":"https://www.wikidata.org/wiki/Q11388","display_name":"Infrared","level":2,"score":0.578977108001709},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.5529239773750305},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5247799754142761},{"id":"https://openalex.org/C2779537118","wikidata":"https://www.wikidata.org/wiki/Q618362","display_name":"Arterial blood","level":2,"score":0.5183088183403015},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.491508811712265},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4731394350528717},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.412007212638855},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.32498353719711304},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3039242625236511},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.24141603708267212},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1796671450138092},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12055149674415588},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.07510605454444885},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007231","descriptor_name":"Infant, Newborn","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":"Q000097","qualifier_name":"blood","is_major_topic":false},{"descriptor_ui":"D015278","descriptor_name":"Intensive Care Units, Pediatric","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015278","descriptor_name":"Intensive Care Units, Pediatric","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015278","descriptor_name":"Intensive Care Units, Pediatric","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062485","descriptor_name":"Breath Holding","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062485","descriptor_name":"Breath Holding","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062485","descriptor_name":"Breath Holding","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":5,"locations":[{"id":"doi:10.3390/s18103457","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s18103457","pdf_url":"https://www.mdpi.com/1424-8220/18/10/3457/pdf?version=1539572874","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:30326552","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30326552","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:2142eead73e64735a87f63178bbf3239","is_oa":true,"landing_page_url":"https://doaj.org/article/2142eead73e64735a87f63178bbf3239","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 18, Iss 10, p 3457 (2018)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/18/10/3457/","is_oa":true,"landing_page_url":"http://dx.doi.org/10.3390/s18103457","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:6211094","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/6211094","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s18103457","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s18103457","pdf_url":"https://www.mdpi.com/1424-8220/18/10/3457/pdf?version=1539572874","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Good health and well-being","score":0.4699999988079071,"id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2897441973.pdf","grobid_xml":"https://content.openalex.org/works/W2897441973.grobid-xml"},"referenced_works_count":25,"referenced_works":["https://openalex.org/W98812087","https://openalex.org/W110764138","https://openalex.org/W1757861364","https://openalex.org/W1950905025","https://openalex.org/W1972116768","https://openalex.org/W2014653011","https://openalex.org/W2018997632","https://openalex.org/W2026523023","https://openalex.org/W2032660377","https://openalex.org/W2037353747","https://openalex.org/W2042302956","https://openalex.org/W2079326834","https://openalex.org/W2085115452","https://openalex.org/W2097105186","https://openalex.org/W2117488763","https://openalex.org/W2138385904","https://openalex.org/W2144475623","https://openalex.org/W2151674612","https://openalex.org/W2162501655","https://openalex.org/W2487756862","https://openalex.org/W4232851490","https://openalex.org/W4245109825","https://openalex.org/W6603990565","https://openalex.org/W6604486105","https://openalex.org/W6827297527"],"related_works":["https://openalex.org/W1978176980","https://openalex.org/W2938254392","https://openalex.org/W2884526288","https://openalex.org/W2032224110","https://openalex.org/W2091413177","https://openalex.org/W24219778","https://openalex.org/W2068141149","https://openalex.org/W2898855453","https://openalex.org/W2128609692","https://openalex.org/W2126813252"],"abstract_inverted_index":{"Oxygen":[0],"saturation":[1],"in":[2,29,71,143,157,165,178,183,195],"arterial":[3,73,159,175],"blood":[4,160],"(SaO\u2082)":[5],"provides":[6],"information":[7],"about":[8],"the":[9,12,30,37,56,82,86,131,187,196],"performance":[10],"of":[11,17,26,40,102,181],"respiratory":[13],"system.":[14],"Non-invasive":[15],"measurement":[16,70,156],"SaO\u2082":[18,69,155],"by":[19,43],"commercial":[20,59,137],"pulse":[21,60,97,133,138,147,198],"oximeters":[22,61,148],"(SpO\u2082)":[23],"make":[24],"use":[25,101],"photoplethysmographic":[27],"pulses":[28],"red":[31],"and":[32,35,45,51,113,115,135,171],"infrared":[33,105],"regions":[34],"utilizes":[36],"different":[38,91],"spectra":[39],"light":[41,49],"absorption":[42],"oxygenated":[44],"de-oxygenated":[46],"hemoglobin.":[47],"Because":[48],"scattering":[50,111],"optical":[52],"path-lengths":[53,83,114,184],"differ":[54],"between":[55,85,186],"two":[57,87,103,146,188],"wavelengths,":[58],"require":[62,118],"empirical":[63],"calibration":[64,121],"which":[65,99],"is":[66],"based":[67],"on":[68,126,169],"extracted":[72,158],"blood.":[74],"They":[75],"are":[76,190],"still":[77],"prone":[78],"to":[79,154,192],"error,":[80],"because":[81,180],"difference":[84,185],"wavelengths":[88,106,189],"varies":[89],"among":[90],"subjects.":[92],"We":[93],"have":[94,108],"developed":[95],"modified":[96],"oximetry,":[98],"makes":[100],"nearby":[104],"that":[107],"relatively":[109],"similar":[110,141,150],"constants":[112],"does":[116],"not":[117],"an":[119,174],"invasive":[120],"step.":[122],"In":[123],"measurements":[124],"performed":[125,164],"adults":[127],"during":[128],"breath":[129],"holding,":[130],"two-infrared":[132,197],"oximeter":[134,139],"a":[136],"showed":[140,149],"changes":[142],"SpO\u2082.":[144],"The":[145],"accuracy":[151],"when":[152],"compared":[153],"(the":[161],"gold":[162],"standard)":[163],"intensive":[166],"care":[167],"units":[168],"newborns":[170],"children":[172],"with":[173],"line.":[176],"Errors":[177],"SpO\u2082":[179],"variability":[182],"expected":[191],"be":[193],"smaller":[194],"oximeter.":[199]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2018-10-26T00:00:00"}
