{"id":"https://openalex.org/W2572623725","doi":"https://doi.org/10.3390/s17010158","title":"A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors","display_name":"A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors","publication_year":2017,"publication_date":"2017-01-14","ids":{"openalex":"https://openalex.org/W2572623725","doi":"https://doi.org/10.3390/s17010158","mag":"2572623725","pmid":"https://pubmed.ncbi.nlm.nih.gov/28098831"},"language":"en","primary_location":{"id":"doi:10.3390/s17010158","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s17010158","pdf_url":"https://www.mdpi.com/1424-8220/17/1/158/pdf?version=1484563447","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/1424-8220/17/1/158/pdf?version=1484563447","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049638664","display_name":"Maik Pflugradt","orcid":null},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Maik Pflugradt","raw_affiliation_strings":["Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061423026","display_name":"Kai Geissdoerfer","orcid":"https://orcid.org/0000-0002-4899-7466"},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Kai Geissdoerfer","raw_affiliation_strings":["Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054143684","display_name":"Matthias Goernig","orcid":null},"institutions":[{"id":"https://openalex.org/I4210090100","display_name":"St\u00e4dtisches Klinikum Dresden","ror":"https://ror.org/007gt1a87","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210090100"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Matthias Goernig","raw_affiliation_strings":["Staedtisches Klinikum Dresden-Neustadt, 01159 Dresden, Germany"],"affiliations":[{"raw_affiliation_string":"Staedtisches Klinikum Dresden-Neustadt, 01159 Dresden, Germany","institution_ids":["https://openalex.org/I4210090100"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5047222737","display_name":"Reinhold Orglmeister","orcid":null},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Reinhold Orglmeister","raw_affiliation_strings":["Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5047222737"],"corresponding_institution_ids":["https://openalex.org/I4577782"],"apc_list":{"value":2400,"currency":"CHF","value_usd":2598},"apc_paid":{"value":1799,"currency":"EUR","value_usd":1940},"fwci":2.8542,"has_fulltext":true,"cited_by_count":19,"citation_normalized_percentile":{"value":0.91882168,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"17","issue":"1","first_page":"158","last_page":"158"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6671671271324158},{"id":"https://openalex.org/keywords/discriminator","display_name":"Discriminator","score":0.5801427364349365},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.5754297971725464},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.43483179807662964},{"id":"https://openalex.org/keywords/pulse-wave-analysis","display_name":"Pulse Wave Analysis","score":0.42058077454566956},{"id":"https://openalex.org/keywords/pulse-wave-velocity","display_name":"Pulse wave velocity","score":0.41276663541793823},{"id":"https://openalex.org/keywords/pulse-wave","display_name":"Pulse wave","score":0.3834354281425476},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.37566888332366943},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35303646326065063},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.3485756516456604},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.19194093346595764},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.13254708051681519},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.1288098394870758},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.12115105986595154}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6671671271324158},{"id":"https://openalex.org/C2779803651","wikidata":"https://www.wikidata.org/wiki/Q5282088","display_name":"Discriminator","level":3,"score":0.5801427364349365},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.5754297971725464},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.43483179807662964},{"id":"https://openalex.org/C2908916285","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse Wave Analysis","level":4,"score":0.42058077454566956},{"id":"https://openalex.org/C2778319312","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse wave velocity","level":3,"score":0.41276663541793823},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.3834354281425476},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.37566888332366943},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35303646326065063},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.3485756516456604},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.19194093346595764},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.13254708051681519},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.1288098394870758},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.12115105986595154},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001794","descriptor_name":"Blood Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":5,"locations":[{"id":"doi:10.3390/s17010158","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s17010158","pdf_url":"https://www.mdpi.com/1424-8220/17/1/158/pdf?version=1484563447","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},{"id":"pmid:28098831","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/28098831","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors (Basel, Switzerland)","raw_type":null},{"id":"pmh:oai:doaj.org/article:c134920d306c4deba763f014da7a2388","is_oa":true,"landing_page_url":"https://doaj.org/article/c134920d306c4deba763f014da7a2388","pdf_url":null,"source":{"id":"https://openalex.org/S112646816","display_name":"SHILAP Revista de lepidopterolog\u00eda","issn_l":"0300-5267","issn":["0300-5267","2340-4078"],"is_oa":true,"is_in_doaj":true,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors, Vol 17, Iss 1, p 158 (2017)","raw_type":"article"},{"id":"pmh:oai:mdpi.com:/1424-8220/17/1/158/","is_oa":true,"landing_page_url":"https://dx.doi.org/10.3390/s17010158","pdf_url":null,"source":{"id":"https://openalex.org/S4306400947","display_name":"MDPI (MDPI AG)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210097602","host_organization_name":"Multidisciplinary Digital Publishing Institute (Switzerland)","host_organization_lineage":["https://openalex.org/I4210097602"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors; Volume 17; Issue 1; Pages: 158","raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:5298731","is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/5298731","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Sensors (Basel)","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.3390/s17010158","is_oa":true,"landing_page_url":"https://doi.org/10.3390/s17010158","pdf_url":"https://www.mdpi.com/1424-8220/17/1/158/pdf?version=1484563447","source":{"id":"https://openalex.org/S101949793","display_name":"Sensors","issn_l":"1424-8220","issn":["1424-8220"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Sensors","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.6800000071525574,"display_name":"Reduced inequalities","id":"https://metadata.un.org/sdg/10"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320879","display_name":"Deutsche Forschungsgemeinschaft","ror":"https://ror.org/018mejw64"},{"id":"https://openalex.org/F4320324094","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2572623725.pdf","grobid_xml":"https://content.openalex.org/works/W2572623725.grobid-xml"},"referenced_works_count":33,"referenced_works":["https://openalex.org/W203249090","https://openalex.org/W1586991009","https://openalex.org/W1594461330","https://openalex.org/W1758044193","https://openalex.org/W1966556266","https://openalex.org/W1994171917","https://openalex.org/W2008989235","https://openalex.org/W2021674224","https://openalex.org/W2063923412","https://openalex.org/W2083872334","https://openalex.org/W2088204643","https://openalex.org/W2103308415","https://openalex.org/W2115283192","https://openalex.org/W2118936660","https://openalex.org/W2123787970","https://openalex.org/W2125299673","https://openalex.org/W2131406018","https://openalex.org/W2135983366","https://openalex.org/W2137483363","https://openalex.org/W2151809653","https://openalex.org/W2162273778","https://openalex.org/W2162800060","https://openalex.org/W2169199307","https://openalex.org/W2169713586","https://openalex.org/W2170195027","https://openalex.org/W2175831944","https://openalex.org/W2327284516","https://openalex.org/W2479650037","https://openalex.org/W2489184882","https://openalex.org/W2541503466","https://openalex.org/W4232851490","https://openalex.org/W4256697785","https://openalex.org/W6684808480"],"related_works":["https://openalex.org/W3152731300","https://openalex.org/W2151351576","https://openalex.org/W2050665136","https://openalex.org/W2070073147","https://openalex.org/W2509132145","https://openalex.org/W2229566709","https://openalex.org/W1996153818","https://openalex.org/W2390282139","https://openalex.org/W2412418861","https://openalex.org/W2028927310"],"abstract_inverted_index":{"Automatic":[0],"detection":[1],"of":[2,20,41,75,82,100],"ectopic":[3,87,127],"beats":[4,128],"has":[5,94],"become":[6],"a":[7,58,85,145,151,161,173,199],"thoroughly":[8],"researched":[9],"topic,":[10],"with":[11,90,193],"literature":[12],"providing":[13,112],"manifold":[14],"proposals":[15],"typically":[16],"incorporating":[17],"morphological":[18],"analysis":[19],"the":[21,80,116,121,136,155,177],"electrocardiogram":[22],"(ECG).":[23],"Although":[24],"being":[25],"well":[26,140],"understood,":[27],"its":[28,186],"utilization":[29],"is":[30,57,69,129,165,198,208],"often":[31],"neglected,":[32],"especially":[33],"in":[34,44,144,150],"practical":[35],"monitoring":[36],"situations":[37],"like":[38],"online":[39],"evaluation":[40],"signals":[42,142],"acquired":[43],"wearable":[45],"sensors.":[46],"Continuous":[47],"blood":[48,122,169],"pressure":[49,123,170],"estimation":[50],"based":[51],"on":[52,63,115,132,176],"pulse":[53,107],"wave":[54,108],"velocity":[55],"considerations":[56],"prominent":[59],"example,":[60],"which":[61,97],"depends":[62],"careful":[64],"fiducial":[65],"point":[66],"extraction":[67],"and":[68,106,197],"therefore":[70],"seriously":[71],"affected":[72],"during":[73],"periods":[74],"increased":[76],"occurring":[77],"extrasystoles.":[78],"In":[79],"scope":[81],"this":[83],"work,":[84],"novel":[86],"beat":[88],"discriminator":[89],"low":[91],"computational":[92],"complexity":[93],"been":[95],"developed,":[96],"takes":[98],"advantage":[99],"multimodal":[101,205],"features":[102,207],"derived":[103],"from":[104,135],"ECG":[105],"relating":[109],"measurements,":[110],"thereby":[111],"additional":[113],"information":[114],"underlying":[117],"cardiac":[118],"activity.":[119],"Moreover,":[120],"estimations'":[124],"vulnerability":[125],"towards":[126],"closely":[130],"examined":[131],"records":[133],"drawn":[134],"Physionet":[137],"database":[138],"as":[139,141],"recorded":[143],"small":[146],"field":[147],"study":[148],"conducted":[149],"geriatric":[152],"facility":[153],"for":[154],"elderly.":[156],"It":[157],"turns":[158],"out":[159],"that":[160],"reliable":[162],"extrasystole":[163],"identification":[164],"essential":[166],"to":[167,188,204],"unsupervised":[168],"estimation,":[171],"having":[172],"significant":[174],"impact":[175],"overall":[178],"accuracy.":[179],"The":[180],"proposed":[181],"method":[182],"further":[183],"convinces":[184],"by":[185],"applicability":[187],"battery":[189],"driven":[190],"hardware":[191],"systems":[192],"limited":[194],"processing":[195],"power":[196],"favorable":[200],"choice":[201],"when":[202],"access":[203],"signal":[206],"given":[209],"anyway.":[210]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":3}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}
