{"id":"https://openalex.org/W4281697008","doi":"https://doi.org/10.32604/iasc.2023.026496","title":"Effective Energy Management Scheme by IMPC","display_name":"Effective Energy Management Scheme by IMPC","publication_year":2022,"publication_date":"2022-06-06","ids":{"openalex":"https://openalex.org/W4281697008","doi":"https://doi.org/10.32604/iasc.2023.026496"},"language":"en","primary_location":{"id":"doi:10.32604/iasc.2023.026496","is_oa":true,"landing_page_url":"https://doi.org/10.32604/iasc.2023.026496","pdf_url":"https://file.techscience.com/ueditor/files/iasc/TSP_IASC-35-1/TSP_IASC_26496/TSP_IASC_26496.pdf","source":{"id":"https://openalex.org/S40639465","display_name":"Intelligent Automation & Soft Computing","issn_l":"1079-8587","issn":["1079-8587","2326-005X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547"],"host_organization_lineage_names":["Taylor & Francis"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Intelligent Automation &amp; Soft Computing","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://file.techscience.com/ueditor/files/iasc/TSP_IASC-35-1/TSP_IASC_26496/TSP_IASC_26496.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101984344","display_name":"Smarajit Ghosh","orcid":"https://orcid.org/0000-0003-2943-5908"},"institutions":[{"id":"https://openalex.org/I162030827","display_name":"Thapar Institute of Engineering & Technology","ror":"https://ror.org/00wdq3744","country_code":"IN","type":"education","lineage":["https://openalex.org/I162030827"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Smarajit Ghosh","raw_affiliation_strings":["Department of Electrical and Instrumentation Engineering, Thapar Institute of Engineering & Technology, Patiala, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Instrumentation Engineering, Thapar Institute of Engineering & Technology, Patiala, India","institution_ids":["https://openalex.org/I162030827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5101984344"],"corresponding_institution_ids":["https://openalex.org/I162030827"],"apc_list":null,"apc_paid":null,"fwci":0.2744,"has_fulltext":true,"cited_by_count":3,"citation_normalized_percentile":{"value":0.51587447,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":"35","issue":"1","first_page":"181","last_page":"197"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8031929731369019},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.5782928466796875},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.5664771795272827},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.5633160471916199},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5353831052780151},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5074381232261658},{"id":"https://openalex.org/keywords/power-management","display_name":"Power management","score":0.505842924118042},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4945940673351288},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.49178412556648254},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.4831785261631012},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.455597847700119},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.4496241509914398},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.4359934628009796},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3660159409046173},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.354947566986084},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.337085485458374},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2179877758026123},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.15595808625221252},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.08876225352287292},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08820807933807373}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8031929731369019},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.5782928466796875},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.5664771795272827},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.5633160471916199},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5353831052780151},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5074381232261658},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.505842924118042},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4945940673351288},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.49178412556648254},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4831785261631012},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.455597847700119},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.4496241509914398},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.4359934628009796},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3660159409046173},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.354947566986084},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.337085485458374},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2179877758026123},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.15595808625221252},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08876225352287292},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08820807933807373},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.32604/iasc.2023.026496","is_oa":true,"landing_page_url":"https://doi.org/10.32604/iasc.2023.026496","pdf_url":"https://file.techscience.com/ueditor/files/iasc/TSP_IASC-35-1/TSP_IASC_26496/TSP_IASC_26496.pdf","source":{"id":"https://openalex.org/S40639465","display_name":"Intelligent Automation & Soft Computing","issn_l":"1079-8587","issn":["1079-8587","2326-005X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547"],"host_organization_lineage_names":["Taylor & Francis"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Intelligent Automation &amp; Soft Computing","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.32604/iasc.2023.026496","is_oa":true,"landing_page_url":"https://doi.org/10.32604/iasc.2023.026496","pdf_url":"https://file.techscience.com/ueditor/files/iasc/TSP_IASC-35-1/TSP_IASC_26496/TSP_IASC_26496.pdf","source":{"id":"https://openalex.org/S40639465","display_name":"Intelligent Automation & Soft Computing","issn_l":"1079-8587","issn":["1079-8587","2326-005X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547"],"host_organization_lineage_names":["Taylor & Francis"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Intelligent Automation &amp; Soft Computing","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Responsible consumption and production","score":0.44999998807907104,"id":"https://metadata.un.org/sdg/12"}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4281697008.pdf","grobid_xml":"https://content.openalex.org/works/W4281697008.grobid-xml"},"referenced_works_count":24,"referenced_works":["https://openalex.org/W2331968372","https://openalex.org/W2741211397","https://openalex.org/W2767897971","https://openalex.org/W2789880759","https://openalex.org/W2792003962","https://openalex.org/W2793250060","https://openalex.org/W2794632970","https://openalex.org/W2804066948","https://openalex.org/W2807882570","https://openalex.org/W2883821839","https://openalex.org/W2886231148","https://openalex.org/W2901868935","https://openalex.org/W2902621306","https://openalex.org/W2911306702","https://openalex.org/W2913974632","https://openalex.org/W2914867085","https://openalex.org/W2915435825","https://openalex.org/W2937416166","https://openalex.org/W2953615535","https://openalex.org/W2955276469","https://openalex.org/W2973511753","https://openalex.org/W3003480495","https://openalex.org/W4232608232","https://openalex.org/W6749380045"],"related_works":["https://openalex.org/W2768314333","https://openalex.org/W2009641913","https://openalex.org/W3132422838","https://openalex.org/W1537166562","https://openalex.org/W3125893599","https://openalex.org/W3132307129","https://openalex.org/W2087694107","https://openalex.org/W2893433204","https://openalex.org/W2202249113","https://openalex.org/W2234781479"],"abstract_inverted_index":{"The":[0,157,166,180],"primary":[1],"purpose":[2],"of":[3,56,64,99,126,170],"the":[4,12,17,23,31,34,62,70,91,102,110,115,124,129,133,138,154,163,171,199,202,206,217],"Energy":[5,74],"Management":[6],"Scheme":[7],"(EMS)":[8],"is":[9,28,67,94,107,135,141,151,160,174,209],"to":[10,114,213],"monitor":[11],"energy":[13,167],"fluctuations":[14],"present":[15],"in":[16,33,97,132,153,162],"load":[18,57],"profile.":[19],"In":[20,118],"this":[21],"paper,":[22],"improved":[24,119],"model":[25,120,150],"predictive":[26,121],"controller":[27],"adopted":[29],"for":[30,53,128,176,190],"EMS":[32,66],"power":[35,59,71,130],"system.":[36],"Emperor":[37],"Penguin":[38],"Optimization":[39],"(EPO)":[40],"algorithm":[41],"optimized":[42,136],"Artificial":[43],"Neural":[44],"Network":[45],"(ANN)":[46],"with":[47,89,109],"Model":[48],"Predictive":[49],"Control":[50],"(MPC)":[51],"scheme":[52],"accurate":[54],"prediction":[55,149],"and":[58,82,112,187,195],"forecasting":[60],"at":[61],"time":[63],"pre-optimizing":[65],"presented.":[68],"For":[69],"generation,":[72],"Renewable":[73],"Sources":[75],"(RES)":[76],"such":[77],"as":[78],"photo":[79],"voltaic":[80],"(PV)":[81],"wind":[83],"turbine":[84],"(WT)":[85],"are":[86,192],"utilized":[87],"along":[88],"that":[90,214],"fuel":[92],"cell":[93],"also":[95],"presented":[96,152],"case":[98],"failure":[100],"by":[101,137,143,205,216],"RES.":[103],"Such":[104,145],"a":[105,146],"setup":[106],"connected":[108],"grid":[111],"applies":[113],"household":[116],"appliances.":[117],"control":[122],"(IMPC),":[123],"set":[125],"constraints":[127],"flow":[131],"system":[134,173,182],"ANN,":[139],"which":[140],"trained":[142],"EPO.":[144],"tuning":[147],"based":[148],"IMPC":[155,191],"technique.":[156],"proposed":[158,172,207],"work":[159],"implemented":[161],"MATLAB/Simulink":[164],"platform.":[165],"management":[168],"capability":[169],"analyzed":[175],"different":[177],"atmospheric":[178],"conditions.":[179],"total":[181],"cost,":[183],"life":[184],"cycle":[185],"cost":[186,189,203],"annualized":[188],"48%,":[193],"45%":[194],"15%,":[196],"respectively.":[197],"From":[198],"performance":[200],"analysis,":[201],"obtained":[204,215],"method":[208],"very":[210],"low":[211],"compared":[212],"existing":[218],"techniques.":[219]},"counts_by_year":[{"year":2024,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
