{"id":"https://openalex.org/W4415729667","doi":"https://doi.org/10.32604/cmc.2025.070577","title":"Mitigating the Dynamic Load Altering Attack on Load Frequency Control with Network Parameter Regulation","display_name":"Mitigating the Dynamic Load Altering Attack on Load Frequency Control with Network Parameter Regulation","publication_year":2025,"publication_date":"2025-10-31","ids":{"openalex":"https://openalex.org/W4415729667","doi":"https://doi.org/10.32604/cmc.2025.070577"},"language":"en","primary_location":{"id":"doi:10.32604/cmc.2025.070577","is_oa":true,"landing_page_url":"https://doi.org/10.32604/cmc.2025.070577","pdf_url":"https://cdn.techscience.press/files/cmc/2025/TSP_CMC-86-2/TSP_CMC_70577/TSP_CMC_70577.pdf","source":{"id":"https://openalex.org/S4210191605","display_name":"Computers, materials & continua/Computers, materials & continua (Print)","issn_l":"1546-2218","issn":["1546-2218","1546-2226"],"is_oa":true,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Computers, Materials &amp; Continua","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://cdn.techscience.press/files/cmc/2025/TSP_CMC-86-2/TSP_CMC_70577/TSP_CMC_70577.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5092096271","display_name":"Yunhao Yu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yunhao Yu","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063699309","display_name":"Boda Zhang","orcid":"https://orcid.org/0000-0002-1854-4335"},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Boda Zhang","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5119417077","display_name":"Meiling Dizha","orcid":null},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Meiling Dizha","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013367907","display_name":"Ruibin Wen","orcid":null},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ruibin Wen","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110993476","display_name":"Fuhua Luo","orcid":null},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fuhua Luo","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103809775","display_name":"Xiang Guo","orcid":"https://orcid.org/0000-0002-2727-4066"},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiang Guo","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035143434","display_name":"Zhenyong Zhang","orcid":"https://orcid.org/0000-0003-0950-1525"},"institutions":[{"id":"https://openalex.org/I4210145500","display_name":"Guizhou Electric Power Design and Research Institute","ror":"https://ror.org/055f13495","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210145500"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhenyong Zhang","raw_affiliation_strings":["Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang, 550002, China 2 State Key Laboratory of Public Big Data, College of Computer Science and Technology, Guizhou University, Guiyang, 550025, China","institution_ids":["https://openalex.org/I4210145500"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210145500"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.34770046,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"86","issue":"2","first_page":"1","last_page":"19"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.7477999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.7477999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.15970000624656677,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0210999995470047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.6542999744415283},{"id":"https://openalex.org/keywords/frequency-regulation","display_name":"Frequency regulation","score":0.6495000123977661},{"id":"https://openalex.org/keywords/dynamic-demand","display_name":"Dynamic demand","score":0.5442000031471252},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5320000052452087},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.5224000215530396},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.492900013923645},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.47589999437332153},{"id":"https://openalex.org/keywords/frequency-grid","display_name":"Frequency grid","score":0.4749000072479248},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.45820000767707825}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6604999899864197},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6542999744415283},{"id":"https://openalex.org/C2983304839","wikidata":"https://www.wikidata.org/wiki/Q1747997","display_name":"Frequency regulation","level":4,"score":0.6495000123977661},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.5442000031471252},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5320000052452087},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.5224000215530396},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.492900013923645},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.47589999437332153},{"id":"https://openalex.org/C21905445","wikidata":"https://www.wikidata.org/wiki/Q5502873","display_name":"Frequency grid","level":3,"score":0.4749000072479248},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.45820000767707825},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.45750001072883606},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.45730000734329224},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44279998540878296},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.3684999942779541},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.3614000082015991},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.353300005197525},{"id":"https://openalex.org/C12839126","wikidata":"https://www.wikidata.org/wiki/Q5318989","display_name":"Dynamic load testing","level":2,"score":0.34049999713897705},{"id":"https://openalex.org/C2776098794","wikidata":"https://www.wikidata.org/wiki/Q6663315","display_name":"Load regulation","level":3,"score":0.33799999952316284},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.33059999346733093},{"id":"https://openalex.org/C2780848588","wikidata":"https://www.wikidata.org/wiki/Q210494","display_name":"Power Balance","level":3,"score":0.31949999928474426},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.2971999943256378},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.28790000081062317},{"id":"https://openalex.org/C123919525","wikidata":"https://www.wikidata.org/wiki/Q761942","display_name":"Frequency deviation","level":3,"score":0.28220000863075256},{"id":"https://openalex.org/C104122410","wikidata":"https://www.wikidata.org/wiki/Q1416406","display_name":"Network model","level":2,"score":0.27379998564720154},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.2621000111103058},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.25440001487731934},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.25270000100135803}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.32604/cmc.2025.070577","is_oa":true,"landing_page_url":"https://doi.org/10.32604/cmc.2025.070577","pdf_url":"https://cdn.techscience.press/files/cmc/2025/TSP_CMC-86-2/TSP_CMC_70577/TSP_CMC_70577.pdf","source":{"id":"https://openalex.org/S4210191605","display_name":"Computers, materials & continua/Computers, materials & continua (Print)","issn_l":"1546-2218","issn":["1546-2218","1546-2226"],"is_oa":true,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Computers, Materials &amp; Continua","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.32604/cmc.2025.070577","is_oa":true,"landing_page_url":"https://doi.org/10.32604/cmc.2025.070577","pdf_url":"https://cdn.techscience.press/files/cmc/2025/TSP_CMC-86-2/TSP_CMC_70577/TSP_CMC_70577.pdf","source":{"id":"https://openalex.org/S4210191605","display_name":"Computers, materials & continua/Computers, materials & continua (Print)","issn_l":"1546-2218","issn":["1546-2218","1546-2226"],"is_oa":true,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Computers, Materials &amp; Continua","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G3987407865","display_name":null,"funder_award_id":"2024]014","funder_id":"https://openalex.org/F4320329858","funder_display_name":"Major Scientific and Technological Special Project of Guizhou Province"}],"funders":[{"id":"https://openalex.org/F4320321927","display_name":"Guizhou University","ror":"https://ror.org/02wmsc916"},{"id":"https://openalex.org/F4320329858","display_name":"Major Scientific and Technological Special Project of Guizhou Province","ror":null}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4415729667.pdf","grobid_xml":"https://content.openalex.org/works/W4415729667.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Load":[0],"frequency":[1,17,63,87],"control":[2],"(LFC)":[3],"is":[4,18,50,106],"a":[5,19,51,150],"critical":[6],"function":[7],"to":[8,64,95,159,170],"balance":[9],"the":[10,26,36,57,61,77,82,85,90,97,102,110,113,119,128,137,145,161,172,175,179,193,207],"power":[11,58],"consumption":[12],"and":[13,30,88,121,139,157,177,199],"generation.":[14],"The":[15,44,184],"grid":[16,62,86],"crucial":[20],"indicator":[21],"for":[22,33],"maintaining":[23],"balance.":[24],"However,":[25],"widely":[27],"used":[28],"information":[29],"communication":[31],"infrastructure":[32,155],"LFC":[34,104,126],"increases":[35],"risk":[37],"of":[38,79,84,112,130,174,182,195,206],"being":[39],"attacked":[40],"by":[41,108],"malicious":[42],"actors.":[43],"dynamic":[45,103,132],"load":[46],"altering":[47],"attack":[48,53],"(DLAA)":[49],"typical":[52],"that":[54],"can":[55,189],"destabilize":[56],"system,":[59],"causing":[60],"deviate":[65],"from":[66],"its":[67,123,141,154],"nominal":[68],"value.":[69],"Therefore,":[70],"in":[71,143,204],"this":[72],"paper,":[73],"we":[74,117,135,148,165],"mathematically":[75],"analyze":[76,122],"impact":[78,124,173,194],"DLAA":[80,120,176,196],"on":[81,125],"stability":[83],"propose":[89],"network":[91,114],"parameter":[92],"regulation":[93],"(NPR)":[94],"mitigate":[96,192],"impact.":[98],"To":[99],"begin":[100],"with,":[101],"model":[105,118,136],"constructed":[107],"highlighting":[109],"importance":[111],"parameter.":[115],"Then,":[116],"using":[127],"theory":[129],"second-order":[131],"systems.":[133],"Finally,":[134,164],"NPR":[138,152,187],"prove":[140],"effect":[142],"mitigating":[144],"DLAA.":[146],"Besides,":[147],"construct":[149],"least-effort":[151],"considering":[153],"cost":[156],"aim":[158],"reduce":[160],"operation":[162,208],"cost.":[163,209],"carry":[166],"out":[167],"extensive":[168],"simulations":[169],"demonstrate":[171],"evaluate":[178],"mitigation":[180],"performance":[181],"NPR.":[183],"proposed":[185],"cost-benefit":[186],"approach":[188],"not":[190],"only":[191],"with":[197],"100%":[198],"also":[200],"save":[201],"41.18":[202],"$/MWh":[203],"terms":[205]},"counts_by_year":[],"updated_date":"2026-06-25T06:16:34.145877","created_date":"2025-10-31T00:00:00"}