{"id":"https://openalex.org/W4413051921","doi":"https://doi.org/10.3233/shti251201","title":"Non-Contact Electromyography Measurement Based on Coupling Sensing Technology for Smart Healthcare Applications","display_name":"Non-Contact Electromyography Measurement Based on Coupling Sensing Technology for Smart Healthcare Applications","publication_year":2025,"publication_date":"2025-08-07","ids":{"openalex":"https://openalex.org/W4413051921","doi":"https://doi.org/10.3233/shti251201","pmid":"https://pubmed.ncbi.nlm.nih.gov/40776218"},"language":"en","primary_location":{"id":"doi:10.3233/shti251201","is_oa":true,"landing_page_url":"https://doi.org/10.3233/shti251201","pdf_url":null,"source":{"id":"https://openalex.org/S4210179765","display_name":"Studies in health technology and informatics","issn_l":"0926-9630","issn":["0926-9630","1879-8365"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"book series"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in Health Technology and Informatics","raw_type":"book-chapter"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.3233/shti251201","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025540271","display_name":"Yu-Chiao Tsai","orcid":null},"institutions":[{"id":"https://openalex.org/I142066694","display_name":"ITRI International","ror":"https://ror.org/04wwsbd59","country_code":"US","type":"facility","lineage":["https://openalex.org/I142066694"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Yu-Chiao Tsai","raw_affiliation_strings":["Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute"],"raw_orcid":"https://orcid.org/0009-0008-2010-5041","affiliations":[{"raw_affiliation_string":"Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute","institution_ids":["https://openalex.org/I142066694"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008966634","display_name":"Yunyi Huang","orcid":null},"institutions":[{"id":"https://openalex.org/I142066694","display_name":"ITRI International","ror":"https://ror.org/04wwsbd59","country_code":"US","type":"facility","lineage":["https://openalex.org/I142066694"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yun-Yi Huang","raw_affiliation_strings":["Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute","institution_ids":["https://openalex.org/I142066694"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007050963","display_name":"Chun Liu","orcid":"https://orcid.org/0000-0003-1404-340X"},"institutions":[{"id":"https://openalex.org/I142066694","display_name":"ITRI International","ror":"https://ror.org/04wwsbd59","country_code":"US","type":"facility","lineage":["https://openalex.org/I142066694"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Chun Liu","raw_affiliation_strings":["Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute","institution_ids":["https://openalex.org/I142066694"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038317627","display_name":"Heng\u2010Yin Chen","orcid":null},"institutions":[{"id":"https://openalex.org/I142066694","display_name":"ITRI International","ror":"https://ror.org/04wwsbd59","country_code":"US","type":"facility","lineage":["https://openalex.org/I142066694"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Heng-Yin Chen","raw_affiliation_strings":["Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronic and Optoelectronic System Research Laboratories, Industrial Technology Research Institute","institution_ids":["https://openalex.org/I142066694"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5025540271"],"corresponding_institution_ids":["https://openalex.org/I142066694"],"apc_list":null,"apc_paid":null,"fwci":5.8943,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.95125493,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"329","issue":null,"first_page":"1760","last_page":"1761"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9320999979972839,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9320999979972839,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9279000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromyography","display_name":"Electromyography","score":0.7496737837791443},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.7236721515655518},{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.648703932762146},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5361461639404297},{"id":"https://openalex.org/keywords/rehabilitation","display_name":"Rehabilitation","score":0.4864501655101776},{"id":"https://openalex.org/keywords/coupling","display_name":"Coupling (piping)","score":0.4810212254524231},{"id":"https://openalex.org/keywords/capacitive-coupling","display_name":"Capacitive coupling","score":0.4251977503299713},{"id":"https://openalex.org/keywords/wearable-technology","display_name":"Wearable technology","score":0.4241166114807129},{"id":"https://openalex.org/keywords/physical-medicine-and-rehabilitation","display_name":"Physical medicine and rehabilitation","score":0.28735247254371643},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25877225399017334},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19749554991722107},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.18952110409736633},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.15613919496536255},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.13401088118553162},{"id":"https://openalex.org/keywords/physical-therapy","display_name":"Physical therapy","score":0.11492928862571716},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.07566311955451965}],"concepts":[{"id":"https://openalex.org/C2777515770","wikidata":"https://www.wikidata.org/wiki/Q507369","display_name":"Electromyography","level":2,"score":0.7496737837791443},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.7236721515655518},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.648703932762146},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5361461639404297},{"id":"https://openalex.org/C2778818304","wikidata":"https://www.wikidata.org/wiki/Q1819478","display_name":"Rehabilitation","level":2,"score":0.4864501655101776},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.4810212254524231},{"id":"https://openalex.org/C68278764","wikidata":"https://www.wikidata.org/wiki/Q444167","display_name":"Capacitive coupling","level":3,"score":0.4251977503299713},{"id":"https://openalex.org/C54290928","wikidata":"https://www.wikidata.org/wiki/Q4845080","display_name":"Wearable technology","level":3,"score":0.4241166114807129},{"id":"https://openalex.org/C99508421","wikidata":"https://www.wikidata.org/wiki/Q2678675","display_name":"Physical medicine and rehabilitation","level":1,"score":0.28735247254371643},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25877225399017334},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19749554991722107},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.18952110409736633},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.15613919496536255},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.13401088118553162},{"id":"https://openalex.org/C1862650","wikidata":"https://www.wikidata.org/wiki/Q186005","display_name":"Physical therapy","level":1,"score":0.11492928862571716},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.07566311955451965},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004576","descriptor_name":"Electromyography","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D018670","descriptor_name":"Monitoring, Ambulatory","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.3233/shti251201","is_oa":true,"landing_page_url":"https://doi.org/10.3233/shti251201","pdf_url":null,"source":{"id":"https://openalex.org/S4210179765","display_name":"Studies in health technology and informatics","issn_l":"0926-9630","issn":["0926-9630","1879-8365"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"book series"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in Health Technology and Informatics","raw_type":"book-chapter"},{"id":"pmid:40776218","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/40776218","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in health technology and informatics","raw_type":null}],"best_oa_location":{"id":"doi:10.3233/shti251201","is_oa":true,"landing_page_url":"https://doi.org/10.3233/shti251201","pdf_url":null,"source":{"id":"https://openalex.org/S4210179765","display_name":"Studies in health technology and informatics","issn_l":"0926-9630","issn":["0926-9630","1879-8365"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"book series"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in Health Technology and Informatics","raw_type":"book-chapter"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2768092448","https://openalex.org/W2895758062","https://openalex.org/W2048683560","https://openalex.org/W2044770004","https://openalex.org/W1966070768","https://openalex.org/W3090300519","https://openalex.org/W2514492205","https://openalex.org/W4250401876","https://openalex.org/W2943851981","https://openalex.org/W2566526749"],"abstract_inverted_index":{"This":[0,25],"paper":[1],"introduces":[2],"the":[3,31],"development":[4],"and":[5,63,78],"application":[6],"of":[7,33],"a":[8],"non-contact":[9],"electromyography":[10],"(EMG)":[11],"measurement":[12],"technique":[13],"based":[14],"on":[15],"capacitive":[16],"coupling":[17],"principles":[18],"to":[19,46],"detect":[20],"surface":[21],"muscle":[22],"discharge":[23],"signals.":[24],"innovative":[26],"approach":[27],"not":[28],"only":[29],"eliminates":[30],"limitations":[32],"invasive":[34],"procedures":[35],"but":[36],"also":[37],"achieves":[38],"accurate":[39],"EMG":[40],"signal":[41],"detection":[42],"through":[43],"fabric":[44],"up":[45],"1.5":[47],"mm":[48],"thick.":[49],"Moreover,":[50],"it":[51,67],"can":[52],"be":[53],"integrated":[54],"into":[55],"various":[56],"wearables":[57],"such":[58],"as":[59],"wristbands,":[60],"knee":[61],"braces,":[62],"sports":[64,73],"pants,":[65],"making":[66],"suitable":[68],"for":[69],"diverse":[70],"applications,":[71],"including":[72],"performance":[74],"monitoring,":[75],"physical":[76],"therapy,":[77],"rehabilitation.":[79]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-12-19T19:40:27.379048","created_date":"2025-10-10T00:00:00"}
