{"id":"https://openalex.org/W4311122470","doi":"https://doi.org/10.3233/jifs-223256","title":"SCDAP \u2013secured cluster based data aggregation protocol for energy efficient communication in wireless sensor networks","display_name":"SCDAP \u2013secured cluster based data aggregation protocol for energy efficient communication in wireless sensor networks","publication_year":2022,"publication_date":"2022-12-02","ids":{"openalex":"https://openalex.org/W4311122470","doi":"https://doi.org/10.3233/jifs-223256"},"language":"en","primary_location":{"id":"doi:10.3233/jifs-223256","is_oa":false,"landing_page_url":"https://doi.org/10.3233/jifs-223256","pdf_url":null,"source":{"id":"https://openalex.org/S179157397","display_name":"Journal of Intelligent & Fuzzy Systems","issn_l":"1064-1246","issn":["1064-1246","1875-8967"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent &amp; Fuzzy Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014175160","display_name":"G. Lavanya","orcid":null},"institutions":[{"id":"https://openalex.org/I33585257","display_name":"Anna University, Chennai","ror":"https://ror.org/01qhf1r47","country_code":"IN","type":"education","lineage":["https://openalex.org/I33585257"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"G. Lavanya","raw_affiliation_strings":["Department of Information Science and Technology, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Information Science and Technology, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I33585257"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056686518","display_name":"B. L. Velammal","orcid":"https://orcid.org/0000-0002-4878-193X"},"institutions":[{"id":"https://openalex.org/I33585257","display_name":"Anna University, Chennai","ror":"https://ror.org/01qhf1r47","country_code":"IN","type":"education","lineage":["https://openalex.org/I33585257"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"B.L. Velammal","raw_affiliation_strings":["Department of Computer Science and Engineering, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Science and Engineering, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I33585257"]}]},{"author_position":"last","author":{"id":null,"display_name":"K. Kulothungan","orcid":null},"institutions":[{"id":"https://openalex.org/I33585257","display_name":"Anna University, Chennai","ror":"https://ror.org/01qhf1r47","country_code":"IN","type":"education","lineage":["https://openalex.org/I33585257"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"K. Kulothungan","raw_affiliation_strings":["Department of Information Science and Technology, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Information Science and Technology, College of Engineering Guindy, Anna University, Chennai, Tamil Nadu, India","institution_ids":["https://openalex.org/I33585257"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5014175160"],"corresponding_institution_ids":["https://openalex.org/I33585257"],"apc_list":null,"apc_paid":null,"fwci":0.4273,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.64692602,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":96},"biblio":{"volume":"44","issue":"3","first_page":"4747","last_page":"4757"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8055902123451233},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.756608784198761},{"id":"https://openalex.org/keywords/data-aggregator","display_name":"Data aggregator","score":0.7289663553237915},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.7164497971534729},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5933796167373657},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.5331496596336365},{"id":"https://openalex.org/keywords/authentication","display_name":"Authentication (law)","score":0.4909375011920929},{"id":"https://openalex.org/keywords/key-distribution-in-wireless-sensor-networks","display_name":"Key distribution in wireless sensor networks","score":0.47865331172943115},{"id":"https://openalex.org/keywords/data-integrity","display_name":"Data integrity","score":0.4121853709220886},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.3453320562839508},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.33143264055252075},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.2574535608291626},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.12782633304595947},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.07857105135917664}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8055902123451233},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.756608784198761},{"id":"https://openalex.org/C82578977","wikidata":"https://www.wikidata.org/wiki/Q16773055","display_name":"Data aggregator","level":3,"score":0.7289663553237915},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.7164497971534729},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5933796167373657},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.5331496596336365},{"id":"https://openalex.org/C148417208","wikidata":"https://www.wikidata.org/wiki/Q4825882","display_name":"Authentication (law)","level":2,"score":0.4909375011920929},{"id":"https://openalex.org/C41971633","wikidata":"https://www.wikidata.org/wiki/Q6398155","display_name":"Key distribution in wireless sensor networks","level":4,"score":0.47865331172943115},{"id":"https://openalex.org/C33762810","wikidata":"https://www.wikidata.org/wiki/Q461671","display_name":"Data integrity","level":2,"score":0.4121853709220886},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.3453320562839508},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.33143264055252075},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.2574535608291626},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.12782633304595947},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.07857105135917664},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3233/jifs-223256","is_oa":false,"landing_page_url":"https://doi.org/10.3233/jifs-223256","pdf_url":null,"source":{"id":"https://openalex.org/S179157397","display_name":"Journal of Intelligent & Fuzzy Systems","issn_l":"1064-1246","issn":["1064-1246","1875-8967"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent &amp; Fuzzy Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":28,"referenced_works":["https://openalex.org/W766082629","https://openalex.org/W1798609567","https://openalex.org/W1962529150","https://openalex.org/W1991871638","https://openalex.org/W2031533839","https://openalex.org/W2055817410","https://openalex.org/W2088810783","https://openalex.org/W2325162793","https://openalex.org/W2461759357","https://openalex.org/W2516868778","https://openalex.org/W2551980355","https://openalex.org/W2598980959","https://openalex.org/W2766779070","https://openalex.org/W2768229290","https://openalex.org/W2803689347","https://openalex.org/W2888802365","https://openalex.org/W2898040395","https://openalex.org/W2911036432","https://openalex.org/W2950752059","https://openalex.org/W2963953044","https://openalex.org/W2977793913","https://openalex.org/W3003027058","https://openalex.org/W3029531156","https://openalex.org/W3039830485","https://openalex.org/W3130749441","https://openalex.org/W3164175916","https://openalex.org/W4239644839","https://openalex.org/W6758222689"],"related_works":["https://openalex.org/W2100707674","https://openalex.org/W60586779","https://openalex.org/W1994220746","https://openalex.org/W2387292094","https://openalex.org/W2091654030","https://openalex.org/W2054331612","https://openalex.org/W4310501998","https://openalex.org/W2384950545","https://openalex.org/W1971103114","https://openalex.org/W2557309381"],"abstract_inverted_index":{"A":[0],"network":[1,244,320],"of":[2,33,39,118,147,189,209,242],"real":[3],"time":[4],"devices":[5,41],"that":[6,169,291],"can":[7,170,183],"sense":[8,83],"and":[9,64,84,164,182,204,233,236,268,273,277,289,300,305],"transmit":[10],"the":[11,14,30,53,79,86,90,102,105,123,131,137,148,157,174,187,190,197,207,210,243,252,256,259,292,307,312,319,328],"information":[12,88,95],"from":[13,89,101],"deployed":[15,77],"environment":[16,81],"by":[17,173,245],"using":[18],"multi":[19],"hop":[20],"communication":[21,63],"is":[22,96,115,140,201,262,283],"called":[23,43],"as":[24,44],"Wireless":[25],"Sensor":[26],"Network":[27],"(WSNs).":[28],"Despite":[29],"rapid":[31],"advancement":[32],"WSN,":[34],"where":[35],"an":[36,109],"increasing":[37],"number":[38],"physical":[40,80],"so":[42],"sensors":[45],"nodes":[46,75,103,149],"are":[47,76,166],"connected":[48],"with":[49,56],"each":[50],"other,":[51],"providing":[52],"improved":[54],"security":[55,195,208,229,317],"optimized":[57],"energy":[58,110,124,146,240,297],"consumption":[59,241],"during":[60,130,150,156,196,327],"data":[61,132,135,139,151,155,158,180,194,198,254,275,329],"transmission,":[62],"computation":[65],"remains":[66],"huge":[67],"challenge.":[68],"In":[69,134,212],"wireless":[70,127],"sensor":[71,74,128],"networks,":[72],"numerous":[73],"in":[78,108,126,255,265,286,318],"to":[82,98,104,176,186,226,237,250,323],"collect":[85],"required":[87],"given":[91],"environment.":[92],"The":[93,280],"sensed":[94],"needed":[97],"be":[99,161,171],"transmitted":[100],"control":[106],"station":[107],"efficient":[111,264],"manner.":[112],"Data":[113,219],"aggregation":[114,159,199],"one":[116],"kind":[117],"techniques":[119],"which":[120,142],"will":[121,143],"optimize":[122],"usage":[125],"networks":[129],"transmission.":[133,152],"aggregation,":[136],"unnecessary":[138],"removed":[141],"significantly":[144],"reduce":[145,238],"However,":[153],"collected":[154],"should":[160],"completely":[162],"protected":[163],"there":[165],"various":[167],"threats":[168],"launched":[172],"intruders":[175],"carry":[177],"out":[178],"unauthorised":[179],"access":[181],"cause":[184],"threat":[185],"integrity":[188],"network.":[191,211,257],"Therefore,":[192],"ensuring":[193],"process":[200,249],"very":[202],"important":[203],"essential":[205],"for":[206,271],"this":[213],"paper,":[214],"a":[215],"Secure":[216],"Cluster":[217],"based":[218],"Aggregation":[220],"Protocol":[221],"(SCDAP)":[222],"have":[223],"been":[224],"proposed":[225,260,281,293,313],"provide":[227],"better":[228,316],"through":[230],"secure":[231,247,274],"authentication":[232],"verification":[234,278],"process,":[235],"overall":[239],"implementing":[246],"clustering":[248],"eliminate":[251],"redundant":[253],"Moreover,":[258,311],"system":[261,282,294,314],"more":[263],"generating":[266],"public":[267],"private":[269],"keys":[270],"effective":[272],"transmission":[276],"process.":[279],"experimentally":[284],"tested":[285],"NS-3":[287],"tool":[288],"proves":[290],"reduces":[295],"high":[296],"consumption,":[298],"computational":[299],"communicational":[301],"cost,":[302],"end-to-end":[303],"delay":[304],"improves":[306],"packet":[308],"delivery":[309],"ratio.":[310],"provides":[315],"when":[321],"compared":[322],"other":[324],"existing":[325],"systems":[326],"aggregation.":[330]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
