{"id":"https://openalex.org/W4312070752","doi":"https://doi.org/10.3233/faia220547","title":"Efficient Security Detection Strategy Based on K-Means Algorithm in LPWAN","display_name":"Efficient Security Detection Strategy Based on K-Means Algorithm in LPWAN","publication_year":2022,"publication_date":"2022-12-13","ids":{"openalex":"https://openalex.org/W4312070752","doi":"https://doi.org/10.3233/faia220547"},"language":"en","primary_location":{"id":"doi:10.3233/faia220547","is_oa":true,"landing_page_url":"https://doi.org/10.3233/faia220547","pdf_url":"https://ebooks.iospress.nl/pdf/doi/10.3233/FAIA220547","source":{"id":"https://openalex.org/S4210201731","display_name":"Frontiers in artificial intelligence and applications","issn_l":"0922-6389","issn":["0922-6389","1879-8314"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Frontiers in Artificial Intelligence and Applications","raw_type":"book-chapter"},"type":"book-chapter","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://ebooks.iospress.nl/pdf/doi/10.3233/FAIA220547","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002015587","display_name":"Minhao Jin","orcid":"https://orcid.org/0009-0003-5899-129X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Minhao Jin","raw_affiliation_strings":["State Grid Zhejiang Electric Power Company, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Company, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101300039","display_name":"Shaojie Luo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shaojie Luo","raw_affiliation_strings":["State Grid Zhejiang Electric Power Company, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Company, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101766030","display_name":"Jia\u2010Bin Huang","orcid":"https://orcid.org/0000-0002-0536-3658"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jiabin Huang","raw_affiliation_strings":["State Grid Zhejiang Electric Power Company, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Company, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5074618684","display_name":"Xincheng Zhou","orcid":"https://orcid.org/0009-0005-1104-349X"},"institutions":[{"id":"https://openalex.org/I139759216","display_name":"Beijing University of Posts and Telecommunications","ror":"https://ror.org/04w9fbh59","country_code":"CN","type":"education","lineage":["https://openalex.org/I139759216"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xincheng Zhou","raw_affiliation_strings":["Beijing University of Posts and Telecommunications, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing University of Posts and Telecommunications, China","institution_ids":["https://openalex.org/I139759216"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5074618684"],"corresponding_institution_ids":["https://openalex.org/I139759216"],"apc_list":null,"apc_paid":null,"fwci":0.8529,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.77056561,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12079","display_name":"IoT Networks and Protocols","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12079","display_name":"IoT Networks and Protocols","score":0.9848999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9836000204086304,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12222","display_name":"IoT-based Smart Home Systems","score":0.9567999839782715,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/lpwan","display_name":"LPWAN","score":0.7127938270568848},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6462910175323486},{"id":"https://openalex.org/keywords/upload","display_name":"Upload","score":0.5510256886482239},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.45899680256843567},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4438214600086212},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.42613664269447327},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.42155274748802185},{"id":"https://openalex.org/keywords/data-mining","display_name":"Data mining","score":0.42152485251426697},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.411639928817749},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.4104096293449402},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.36564934253692627},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.32736334204673767},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.300386905670166},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2316083014011383},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.22744184732437134},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14112526178359985},{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.09369435906410217}],"concepts":[{"id":"https://openalex.org/C2776445043","wikidata":"https://www.wikidata.org/wiki/Q20706829","display_name":"LPWAN","level":3,"score":0.7127938270568848},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6462910175323486},{"id":"https://openalex.org/C71901391","wikidata":"https://www.wikidata.org/wiki/Q7126699","display_name":"Upload","level":2,"score":0.5510256886482239},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.45899680256843567},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4438214600086212},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.42613664269447327},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.42155274748802185},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.42152485251426697},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.411639928817749},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.4104096293449402},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.36564934253692627},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32736334204673767},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.300386905670166},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2316083014011383},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.22744184732437134},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14112526178359985},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.09369435906410217},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3233/faia220547","is_oa":true,"landing_page_url":"https://doi.org/10.3233/faia220547","pdf_url":"https://ebooks.iospress.nl/pdf/doi/10.3233/FAIA220547","source":{"id":"https://openalex.org/S4210201731","display_name":"Frontiers in artificial intelligence and applications","issn_l":"0922-6389","issn":["0922-6389","1879-8314"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Frontiers in Artificial Intelligence and Applications","raw_type":"book-chapter"}],"best_oa_location":{"id":"doi:10.3233/faia220547","is_oa":true,"landing_page_url":"https://doi.org/10.3233/faia220547","pdf_url":"https://ebooks.iospress.nl/pdf/doi/10.3233/FAIA220547","source":{"id":"https://openalex.org/S4210201731","display_name":"Frontiers in artificial intelligence and applications","issn_l":"0922-6389","issn":["0922-6389","1879-8314"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Frontiers in Artificial Intelligence and Applications","raw_type":"book-chapter"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.800000011920929,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320336311","display_name":"State Grid Zhejiang Electric Power Company","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4312070752.pdf","grobid_xml":"https://content.openalex.org/works/W4312070752.grobid-xml"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W2025639850","https://openalex.org/W2083576110","https://openalex.org/W2560718015","https://openalex.org/W2907188578","https://openalex.org/W3021390096","https://openalex.org/W3103232291","https://openalex.org/W3127159378","https://openalex.org/W3165713359","https://openalex.org/W3172408309","https://openalex.org/W3208773001","https://openalex.org/W3216081894","https://openalex.org/W3217748719","https://openalex.org/W4200015829","https://openalex.org/W4240239981"],"related_works":["https://openalex.org/W2888892063","https://openalex.org/W2740439328","https://openalex.org/W3088070213","https://openalex.org/W3125356464","https://openalex.org/W2901309327","https://openalex.org/W2923934659","https://openalex.org/W2560463884","https://openalex.org/W2979151211","https://openalex.org/W3030891736","https://openalex.org/W2952763095"],"abstract_inverted_index":{"With":[0],"the":[1,66,80,100,107],"development":[2],"of":[3,14,72,83,106],"multi-element":[4],"integration":[5,102],"and":[6,17,28,60,69,103],"high":[7],"elastic":[8],"power":[9,26],"grid":[10],"construction,":[11],"digital":[12,50],"sensing":[13,45,51],"transmission,":[15],"transformation":[16],"distribution":[18,71,73],"equipment":[19],"in":[20,79],"many":[21],"new":[22],"energy":[23],"sources,":[24],"virtual":[25],"plants":[27],"load":[29],"aggregators":[30],"will":[31],"be":[32,77],"widely":[33],"used.":[34],"In":[35],"this":[36],"environment,":[37],"it":[38],"is":[39],"urgent":[40],"to":[41,47,65],"build":[42],"a":[43],"reliable":[44],"network":[46],"support":[48],"its":[49],"applications":[52],"such":[53],"as":[54],"operation":[55],"state":[56],"sensing,":[57],"data":[58,108],"collection":[59],"demand":[61],"management.":[62],"However,":[63],"due":[64],"large":[67],"number":[68],"wide":[70],"equipment,":[74],"there":[75],"may":[76],"errors":[78],"uploading":[81],"results":[82],"sensors.":[84],"This":[85],"paper":[86],"proposes":[87],"an":[88],"efficient":[89],"security":[90],"detection":[91],"strategy":[92],"based":[93],"on":[94],"K-Means":[95],"algorithm,":[96],"which":[97],"greatly":[98],"improves":[99],"information":[101],"decision":[104],"ability":[105],"center.":[109]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
