{"id":"https://openalex.org/W2402250566","doi":"https://doi.org/10.3233/978-1-61499-022-2-512","title":"Conductometric Catheter-Mounted Pressure Sensor","display_name":"Conductometric Catheter-Mounted Pressure Sensor","publication_year":2012,"publication_date":"2012-01-01","ids":{"openalex":"https://openalex.org/W2402250566","doi":"https://doi.org/10.3233/978-1-61499-022-2-512","mag":"2402250566","pmid":"https://pubmed.ncbi.nlm.nih.gov/22357046"},"language":"en","primary_location":{"id":"doi:10.3233/978-1-61499-022-2-512","is_oa":false,"landing_page_url":"https://doi.org/10.3233/978-1-61499-022-2-512","pdf_url":null,"source":{"id":"https://openalex.org/S4210179765","display_name":"Studies in health technology and informatics","issn_l":"0926-9630","issn":["0926-9630","1879-8365"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"book series"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in Health Technology and Informatics","raw_type":"book-chapter"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109248206","display_name":"Robert Tan","orcid":null},"institutions":[{"id":"https://openalex.org/I161318765","display_name":"University of California, Los Angeles","ror":"https://ror.org/046rm7j60","country_code":"US","type":"education","lineage":["https://openalex.org/I161318765"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Tan Robert","raw_affiliation_strings":["Department of Bioengineering, University of California, Los Angeles"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Bioengineering, University of California, Los Angeles","institution_ids":["https://openalex.org/I161318765"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055947197","display_name":"Peter G. Schulam","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Schulam Peter","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5063073811","display_name":"Jacob J. Schmidt","orcid":"https://orcid.org/0000-0001-8277-6280"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Schmidt Jacob","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4024,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.89871221,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"173","issue":null,"first_page":"512","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9117000102996826,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9117000102996826,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.7379504442214966},{"id":"https://openalex.org/keywords/instrumentation","display_name":"Instrumentation (computer programming)","score":0.675238847732544},{"id":"https://openalex.org/keywords/catheter","display_name":"Catheter","score":0.6693384051322937},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5964577198028564},{"id":"https://openalex.org/keywords/conductance","display_name":"Conductance","score":0.5231426954269409},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.519691526889801},{"id":"https://openalex.org/keywords/electrolyte","display_name":"Electrolyte","score":0.5162475109100342},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.48529547452926636},{"id":"https://openalex.org/keywords/in-vivo","display_name":"In vivo","score":0.4659149944782257},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3804035186767578},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.35532280802726746},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3176323175430298},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.23724320530891418},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.17420867085456848},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.15530726313591003},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.14646106958389282},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.13759368658065796},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.09719899296760559},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08556780219078064}],"concepts":[{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.7379504442214966},{"id":"https://openalex.org/C118530786","wikidata":"https://www.wikidata.org/wiki/Q1134732","display_name":"Instrumentation (computer programming)","level":2,"score":0.675238847732544},{"id":"https://openalex.org/C2781267111","wikidata":"https://www.wikidata.org/wiki/Q652297","display_name":"Catheter","level":2,"score":0.6693384051322937},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5964577198028564},{"id":"https://openalex.org/C121932024","wikidata":"https://www.wikidata.org/wiki/Q5159376","display_name":"Conductance","level":2,"score":0.5231426954269409},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.519691526889801},{"id":"https://openalex.org/C68801617","wikidata":"https://www.wikidata.org/wiki/Q162908","display_name":"Electrolyte","level":3,"score":0.5162475109100342},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.48529547452926636},{"id":"https://openalex.org/C207001950","wikidata":"https://www.wikidata.org/wiki/Q141124","display_name":"In vivo","level":2,"score":0.4659149944782257},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3804035186767578},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.35532280802726746},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3176323175430298},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.23724320530891418},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.17420867085456848},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.15530726313591003},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.14646106958389282},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.13759368658065796},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.09719899296760559},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08556780219078064},{"id":"https://openalex.org/C26873012","wikidata":"https://www.wikidata.org/wiki/Q214781","display_name":"Condensed matter physics","level":1,"score":0.0},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C150903083","wikidata":"https://www.wikidata.org/wiki/Q7108","display_name":"Biotechnology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D001795","descriptor_name":"Blood Pressure Determination","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003217","descriptor_name":"Conductometry","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011312","descriptor_name":"Pressure","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.3233/978-1-61499-022-2-512","is_oa":false,"landing_page_url":"https://doi.org/10.3233/978-1-61499-022-2-512","pdf_url":null,"source":{"id":"https://openalex.org/S4210179765","display_name":"Studies in health technology and informatics","issn_l":"0926-9630","issn":["0926-9630","1879-8365"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310318577","host_organization_name":"IOS Press","host_organization_lineage":["https://openalex.org/P4310318577"],"host_organization_lineage_names":["IOS Press"],"type":"book series"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in Health Technology and Informatics","raw_type":"book-chapter"},{"id":"pmid:22357046","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/22357046","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Studies in health technology and informatics","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.4399999976158142,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4206804491","https://openalex.org/W1973127455","https://openalex.org/W2984836626","https://openalex.org/W3022118013","https://openalex.org/W2534267407","https://openalex.org/W4242883309","https://openalex.org/W2269051159","https://openalex.org/W818971998","https://openalex.org/W2093962749","https://openalex.org/W178109321"],"abstract_inverted_index":{"We":[0,65],"are":[1,28],"developing":[2],"an":[3,59],"in":[4,12,35,43,72],"vivo":[5,36],"pressure":[6,74],"sensor":[7,24],"that":[8],"measures":[9],"the":[10,39,44,51,56,62],"change":[11],"conductance":[13],"of":[14,38],"a":[15],"deformable":[16],"electrolyte-filled":[17],"catheter":[18],"resulting":[19],"from":[20],"external":[21,60],"pressure.":[22],"The":[23,33],"design":[25],"and":[26,31,54,71],"materials":[27],"easily":[29],"scaled":[30],"inexpensive.":[32],"compact,":[34],"nature":[37],"device":[40,69],"may":[41],"result":[42],"compact":[45],"instrumentation":[46],"being":[47],"unobtrusively":[48],"affixed":[49],"to":[50,58],"patient":[52],"externally":[53],"removing":[55],"tethered":[57],"apparatus,":[61],"current":[63],"practice.":[64],"describe":[66],"our":[67],"initial":[68],"construction":[70],"vitro":[73],"measurements.":[75]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
