{"id":"https://openalex.org/W6908562597","doi":"https://doi.org/10.26190/unsworks/16144","title":"Impact and Utilization of Emerging PHEV in Smart Power Systems","display_name":"Impact and Utilization of Emerging PHEV in Smart Power Systems","publication_year":2022,"publication_date":"2022-03-21","ids":{"openalex":"https://openalex.org/W6908562597","doi":"https://doi.org/10.26190/unsworks/16144"},"language":"en","primary_location":{"id":"pmh:oai:unsworks.library.unsw.edu.au:1959.4/52638","is_oa":true,"landing_page_url":"https://unsworks.unsw.edu.au/bitstreams/3026aad9-a338-4e47-8ba4-f210d4563c15/download","pdf_url":null,"source":{"id":"https://openalex.org/S4306401737","display_name":"UNSWorks (University of New South Wales, Sydney, Australia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I40053085","host_organization_name":"Australian Defence Force Academy","host_organization_lineage":["https://openalex.org/I40053085"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"http://purl.org/coar/resource_type/c_db06"},"type":"dissertation","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://unsworks.unsw.edu.au/bitstreams/3026aad9-a338-4e47-8ba4-f210d4563c15/download","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Islam, F.M. Rabiul","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Islam, F.M. Rabiul","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.4526999890804291,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.4526999890804291,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.24889999628067017,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14353","display_name":"Wireless Sensor Networks for Data Analysis","score":0.026900000870227814,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6144000291824341},{"id":"https://openalex.org/keywords/dynamic-demand","display_name":"Dynamic demand","score":0.5835999846458435},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.5667999982833862},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4893999993801117},{"id":"https://openalex.org/keywords/stand-alone-power-system","display_name":"Stand-alone power system","score":0.4496000111103058},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.42989999055862427},{"id":"https://openalex.org/keywords/base-load-power-plant","display_name":"Base load power plant","score":0.4092000126838684},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.4047999978065491},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.40139999985694885},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.39809998869895935}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6144000291824341},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.5835999846458435},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5667999982833862},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5386999845504761},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5356000065803528},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4893999993801117},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.4496000111103058},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42989999055862427},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.4092000126838684},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.4047999978065491},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.40139999985694885},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.39809998869895935},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.3880000114440918},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37459999322891235},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.36160001158714294},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.3587999939918518},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.3555999994277954},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.35030001401901245},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.3499000072479248},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.3416000008583069},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.33550000190734863},{"id":"https://openalex.org/C2777913456","wikidata":"https://www.wikidata.org/wiki/Q2981107","display_name":"Smart power","level":3,"score":0.3319999873638153},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.32420000433921814},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3239000141620636},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.32280001044273376},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.32190001010894775},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.3154999911785126},{"id":"https://openalex.org/C2780068603","wikidata":"https://www.wikidata.org/wiki/Q1783938","display_name":"Vehicle-to-grid","level":4,"score":0.3149999976158142},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.3147999942302704},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.3025999963283539},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.29899999499320984},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.2948000133037567},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.2833000123500824},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.26010000705718994},{"id":"https://openalex.org/C85899133","wikidata":"https://www.wikidata.org/wiki/Q557211","display_name":"Active filter","level":3,"score":0.25110000371932983}],"mesh":[],"locations_count":3,"locations":[{"id":"pmh:oai:unsworks.library.unsw.edu.au:1959.4/52638","is_oa":true,"landing_page_url":"https://unsworks.unsw.edu.au/bitstreams/3026aad9-a338-4e47-8ba4-f210d4563c15/download","pdf_url":null,"source":{"id":"https://openalex.org/S4306401737","display_name":"UNSWorks (University of New South Wales, Sydney, Australia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I40053085","host_organization_name":"Australian Defence Force Academy","host_organization_lineage":["https://openalex.org/I40053085"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"http://purl.org/coar/resource_type/c_db06"},{"id":"pmh:oai:unsworks.unsw.edu.au:1959.4/52638","is_oa":false,"landing_page_url":"http://handle.unsw.edu.au/1959.4/52638","pdf_url":null,"source":{"id":"https://openalex.org/S4377196481","display_name":"UNSWorks (UNSW Sydney)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I31746571","host_organization_name":"UNSW Sydney","host_organization_lineage":["https://openalex.org/I31746571"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Thesis"},{"id":"doi:10.26190/unsworks/16144","is_oa":true,"landing_page_url":"https://doi.org/10.26190/unsworks/16144","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Dissertation"}],"best_oa_location":{"id":"pmh:oai:unsworks.library.unsw.edu.au:1959.4/52638","is_oa":true,"landing_page_url":"https://unsworks.unsw.edu.au/bitstreams/3026aad9-a338-4e47-8ba4-f210d4563c15/download","pdf_url":null,"source":{"id":"https://openalex.org/S4306401737","display_name":"UNSWorks (University of New South Wales, Sydney, Australia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I40053085","host_organization_name":"Australian Defence Force Academy","host_organization_lineage":["https://openalex.org/I40053085"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"http://purl.org/coar/resource_type/c_db06"},"sustainable_development_goals":[{"score":0.7199817299842834,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Quality":[0],"and":[1,17,25,36,45,60,77,110,179,201,253,322,330,385],"stability":[2,159],"are":[3,115,267,327,332],"two":[4],"important":[5,169],"issues":[6],"for":[7,39,79,117,192,269,356],"the":[8,19,31,57,91,137,151,156,162,172,186,207,222,250,277,283,287,339,379,382],"secure":[9],"operation":[10,348],"of":[11,21,48,85,94,124,161,174,182,188,211,244,256,294,316,341,347,381],"power":[12,33,49,80,98,108,163,193,205,213,217,238,252,271,284,309],"systems.":[13,81],"Electricity":[14],"grid":[15,164],"upgrades,":[16],"especially":[18],"construction":[20],"new":[22,46,54],"transmission":[23],"lines":[24],"loads":[26,47],"cannot":[27],"keep":[28],"pace":[29],"with":[30],"growing":[32],"plant":[34],"capacity":[35],"energy":[37],"demand":[38],"various":[40,270],"reasons.":[41],"The":[42,82,158,177,242,290],"changing":[43],"characteristics":[44],"systems":[50],"continue":[51],"to":[52,56,89,143,149,170,224,230,274,298,377],"provide":[53],"challenges":[55],"system":[58,109,114,138,194,272],"designers":[59],"operators.":[61],"Plug":[62],"in":[63,97,216,258,261,343,388],"hybrid":[64],"electric":[65],"vehicle":[66],"(PHEV)":[67],"is":[68,88,126,141,168,185,214,228,264,297,349],"such":[69,313],"a":[70,145,245,344,353,358,370],"load":[71,122,153],"which":[72,305,351],"can":[73,306],"have":[74],"huge":[75],"impact":[76,154],"opportunities":[78],"first":[83],"contribution":[84,181,293],"this":[86,118,183,220,295,337],"work":[87],"identify":[90],"charging":[92,262,367],"effect":[93],"dynamic":[95,121],"PHEV":[96,342,366],"system.":[99,218],"A":[100,120],"single":[101],"machine":[102],"infinite":[103],"bus":[104],"(SMIB)":[105],"system,":[106],"solar":[107],"an":[111],"electricity":[112],"distribution":[113,372],"used":[116,229,376],"purpose.":[119],"model":[123],"PHEVs":[125,152,175],"introduced":[127],"here":[128],"based":[129,235],"on":[130,155,236],"third":[131],"order":[132],"battery":[133],"model.":[134],"To":[135],"determine":[136],"adequacy,":[139],"it":[140,167],"necessary":[142],"do":[144],"micro":[146],"level":[147],"analysis":[148],"know":[150],"grid.":[157,389],"analyses":[160],"demonstrate":[165,275],"that":[166,248,276],"consider":[171],"dynamics":[173],"load.":[176],"second":[178],"unique":[180],"thesis":[184,221],"design":[187,231,299],"virtual":[189,232,279,359],"active":[190,233,280],"filter":[191,234,281,384],"using":[195,302,365],"V2G":[196,303,345],"technology.":[197],"Nonlinear":[198],"loads,":[199],"inverters":[200],"converters":[202],"absorb":[203],"reactive":[204,212,251,317],"from":[206],"connected":[208],"bus.":[209],"Compensation":[210],"essential":[215],"In":[219,336],"Vehicle":[223],"Grid":[225],"(V2G)":[226],"technology":[227,304],"instantaneous":[237],"theory":[239],"(p-q)":[240],"theory.":[241],"potential":[243,340],"low-cost":[246,354],"solution":[247,355],"utilizes":[249],"filtering":[254],"capabilities":[255],"plug":[257],"vehicles":[259],"parked":[260],"stations":[263],"investigated.":[265],"Simulations":[266],"performed":[268],"networks":[273],"proposed":[278,383],"improves":[282],"quality":[285],"maintaining":[286],"IEEE":[288],"standard.":[289],"other":[291],"significant":[292],"research":[296],"FACTS":[300,326,360],"devices":[301,361,387],"fulfil":[307],"multiple":[308],"flow":[310],"control":[311],"objectives":[312],"as":[314],"needs":[315],"shunt":[318],"compensation,":[319],"phase":[320],"shifting":[321],"series":[323],"compensation.":[324],"However":[325],"quite":[328],"expensive":[329],"therefore":[331],"not":[333],"widely":[334],"used.":[335],"dissertation":[338],"mode":[346],"explained,":[350],"gives":[352],"designing":[357],"(UPFC,":[362],"UPQC,":[363],"DVR)":[364],"station.":[368],"Finally,":[369],"benchmark":[371],"network":[373],"has":[374],"been":[375],"verify":[378],"performance":[380],"FACTs":[386]},"counts_by_year":[],"updated_date":"2026-07-28T07:46:37.118299","created_date":"2025-10-10T00:00:00"}
