{"id":"https://openalex.org/W6888865569","doi":"https://doi.org/10.24355/dbbs.084-202407151115-0","title":"Is Additive Construction Ready for Seismic Regions? \u2013 A New Seismic Protective System Enabled by Additive Construction","display_name":"Is Additive Construction Ready for Seismic Regions? \u2013 A New Seismic Protective System Enabled by Additive Construction","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W6888865569","doi":"https://doi.org/10.24355/dbbs.084-202407151115-0"},"language":"en","primary_location":{"id":"pmh:oai:https://leopard.tu-braunschweig.de/:dbbs_mods_00077635","is_oa":true,"landing_page_url":"https://leopard.tu-braunschweig.de/receive/dbbs_mods_00077635","pdf_url":null,"source":{"id":"https://openalex.org/S4306402617","display_name":"Digitale Bibliothek Braunschweig (Verbundzentrale G\u00f6ttingen (VZG))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210149878","host_organization_name":"Verbundzentrale des GBV","host_organization_lineage":["https://openalex.org/I4210149878"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"type":"article","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://leopard.tu-braunschweig.de/receive/dbbs_mods_00077635","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Mackin, Anthony","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Mackin, Anthony","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Migliorino, Jenna","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Migliorino, Jenna","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Farhoud, Hamdy","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Farhoud, Hamdy","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Mantawy, Islam","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mantawy, Islam","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.3490173,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.5277000069618225,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.5277000069618225,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11352","display_name":"Masonry and Concrete Structural Analysis","score":0.25290000438690186,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11874","display_name":"Structural Response to Dynamic Loads","score":0.03180000185966492,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bridge","display_name":"Bridge (graph theory)","score":0.6674000024795532},{"id":"https://openalex.org/keywords/bent-molecular-geometry","display_name":"Bent molecular geometry","score":0.4733000099658966},{"id":"https://openalex.org/keywords/seismic-analysis","display_name":"Seismic analysis","score":0.42980000376701355},{"id":"https://openalex.org/keywords/seismic-energy","display_name":"Seismic energy","score":0.4277999997138977},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.3822999894618988},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.29179999232292175},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.29089999198913574}],"concepts":[{"id":"https://openalex.org/C100776233","wikidata":"https://www.wikidata.org/wiki/Q2532492","display_name":"Bridge (graph theory)","level":2,"score":0.6674000024795532},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.5746999979019165},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5378999710083008},{"id":"https://openalex.org/C138211643","wikidata":"https://www.wikidata.org/wiki/Q675211","display_name":"Bent molecular geometry","level":2,"score":0.4733000099658966},{"id":"https://openalex.org/C182358397","wikidata":"https://www.wikidata.org/wiki/Q2656128","display_name":"Seismic analysis","level":2,"score":0.42980000376701355},{"id":"https://openalex.org/C2993348884","wikidata":"https://www.wikidata.org/wiki/Q186167","display_name":"Seismic energy","level":2,"score":0.4277999997138977},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.3822999894618988},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.36390000581741333},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.29179999232292175},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.29089999198913574},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.2874999940395355},{"id":"https://openalex.org/C2994193878","wikidata":"https://www.wikidata.org/wiki/Q2330355","display_name":"Seismic isolation","level":2,"score":0.287200003862381},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.2732999920845032},{"id":"https://openalex.org/C123060433","wikidata":"https://www.wikidata.org/wiki/Q2026731","display_name":"Seismic loading","level":2,"score":0.2687999904155731},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.2685000002384186},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.26739999651908875},{"id":"https://openalex.org/C136255149","wikidata":"https://www.wikidata.org/wiki/Q5327277","display_name":"Earthquake resistant structures","level":3,"score":0.2612999975681305},{"id":"https://openalex.org/C29979489","wikidata":"https://www.wikidata.org/wiki/Q2468944","display_name":"Seismic retrofit","level":3,"score":0.26100000739097595},{"id":"https://openalex.org/C88282795","wikidata":"https://www.wikidata.org/wiki/Q2448108","display_name":"Structural system","level":2,"score":0.2533000111579895}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:https://leopard.tu-braunschweig.de/:dbbs_mods_00077635","is_oa":true,"landing_page_url":"https://leopard.tu-braunschweig.de/receive/dbbs_mods_00077635","pdf_url":null,"source":{"id":"https://openalex.org/S4306402617","display_name":"Digitale Bibliothek Braunschweig (Verbundzentrale G\u00f6ttingen (VZG))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210149878","host_organization_name":"Verbundzentrale des GBV","host_organization_lineage":["https://openalex.org/I4210149878"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},{"id":"doi:10.24355/dbbs.084-202407151115-0","is_oa":true,"landing_page_url":"https://doi.org/10.24355/dbbs.084-202407151115-0","pdf_url":null,"source":{"id":"https://openalex.org/S7407052991","display_name":"LeoPARD - TU Braunschweig Publications And Research Data","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article-journal"}],"best_oa_location":{"id":"pmh:oai:https://leopard.tu-braunschweig.de/:dbbs_mods_00077635","is_oa":true,"landing_page_url":"https://leopard.tu-braunschweig.de/receive/dbbs_mods_00077635","pdf_url":null,"source":{"id":"https://openalex.org/S4306402617","display_name":"Digitale Bibliothek Braunschweig (Verbundzentrale G\u00f6ttingen (VZG))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210149878","host_organization_name":"Verbundzentrale des GBV","host_organization_lineage":["https://openalex.org/I4210149878"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"sustainable_development_goals":[{"score":0.5293828845024109,"display_name":"Responsible consumption and production","id":"https://metadata.un.org/sdg/12"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Conventional":[0],"design":[1],"for":[2,22,41],"bridges":[3],"in":[4,35],"seismic-prone":[5],"areas":[6],"relies":[7],"on":[8],"duc-tility":[9],"concept":[10],"by":[11],"concentrating":[12],"the":[13,39,51,57,112,121],"damage":[14,30,58],"at":[15,118],"columns\u2019":[16],"ends.":[17],"This":[18,73],"approach":[19],"is":[20],"adequate":[21],"life":[23],"safety;":[24],"however,":[25],"bridge":[26,101],"columns":[27,113,122],"exhibit":[28],"significant":[29],"and":[31,59,69,88,105,123,126],"residual":[32],"deformations":[33],"resulting":[34],"expensive":[36],"repairs":[37],"or":[38],"need":[40],"full":[42],"re-placement.":[43],"Several":[44],"seismic":[45,70,82],"protective":[46,83],"systems":[47],"were":[48],"developed":[49],"over":[50],"last":[52],"few":[53],"decades":[54],"to":[55,85,116,131,134],"minimize":[56],"enable":[60],"repair":[61],"after":[62],"strong":[63],"earthquakes":[64],"like":[65],"rocking":[66],"systems,":[67],"dampers,":[68],"isolation":[71],"systems.":[72],"paper":[74],"proposes":[75],"an":[76],"innovative":[77],"system":[78],"that":[79],"integrates":[80],"several":[81],"concepts":[84],"achieve":[86],"self-repair":[87],"deconstruction":[89],"through":[90],"additive":[91],"construction.":[92],"In":[93,110],"this":[94],"proposed":[95],"system,":[96],"protected":[97],"elements":[98],"such":[99],"as":[100],"bent":[102,124],"caps,":[103],"columns,":[104],"footings":[106],"are":[107,114,129],"additively":[108],"constructed.":[109],"addition,":[111],"designed":[115],"rock":[117],"interfaces":[119],"between":[120],"cap/footing,":[125],"external":[127],"ele-ments":[128],"added":[130],"dissipate":[132],"energy":[133],"promote":[135],"resiliency.":[136]},"counts_by_year":[],"updated_date":"2025-11-06T06:51:31.235846","created_date":"2025-10-10T00:00:00"}
