{"id":"https://openalex.org/W2887753983","doi":"https://doi.org/10.23919/wac.2018.8430462","title":"A Development of Ankle Joint Range of Motion Measurement System Using Electromagnetic Tracking Device and Force Sensor","display_name":"A Development of Ankle Joint Range of Motion Measurement System Using Electromagnetic Tracking Device and Force Sensor","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2887753983","doi":"https://doi.org/10.23919/wac.2018.8430462","mag":"2887753983"},"language":"en","primary_location":{"id":"doi:10.23919/wac.2018.8430462","is_oa":false,"landing_page_url":"https://doi.org/10.23919/wac.2018.8430462","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 World Automation Congress (WAC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066889221","display_name":"Ryo Sakashita","orcid":null},"institutions":[{"id":"https://openalex.org/I111966504","display_name":"University of Fukui","ror":"https://ror.org/00msqp585","country_code":"JP","type":"education","lineage":["https://openalex.org/I111966504"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Ryo Sakashita","raw_affiliation_strings":["Graduate School of Engineering, University of Fukui, Fukui, Japan"],"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, University of Fukui, Fukui, Japan","institution_ids":["https://openalex.org/I111966504"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004948441","display_name":"Kouki Nagamune","orcid":"https://orcid.org/0000-0002-9744-8033"},"institutions":[{"id":"https://openalex.org/I111966504","display_name":"University of Fukui","ror":"https://ror.org/00msqp585","country_code":"JP","type":"education","lineage":["https://openalex.org/I111966504"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kouki Nagamune","raw_affiliation_strings":["Graduate School of Engineering, University of Fukui, Fukui, Japan"],"affiliations":[{"raw_affiliation_string":"Graduate School of Engineering, University of Fukui, Fukui, Japan","institution_ids":["https://openalex.org/I111966504"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071471987","display_name":"Ryosuke Kuroda","orcid":"https://orcid.org/0000-0001-5097-7264"},"institutions":[{"id":"https://openalex.org/I65837984","display_name":"Kobe University","ror":"https://ror.org/03tgsfw79","country_code":"JP","type":"education","lineage":["https://openalex.org/I65837984"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Ryosuke Kuroda","raw_affiliation_strings":["Graduate School of Medicine, Kobe University, Kobe, Japan"],"affiliations":[{"raw_affiliation_string":"Graduate School of Medicine, Kobe University, Kobe, Japan","institution_ids":["https://openalex.org/I65837984"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5066889221"],"corresponding_institution_ids":["https://openalex.org/I111966504"],"apc_list":null,"apc_paid":null,"fwci":0.1617,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.55359923,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11227","display_name":"Diabetic Foot Ulcer Assessment and Management","score":0.8826000094413757,"subfield":{"id":"https://openalex.org/subfields/2712","display_name":"Endocrinology, Diabetes and Metabolism"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11227","display_name":"Diabetic Foot Ulcer Assessment and Management","score":0.8826000094413757,"subfield":{"id":"https://openalex.org/subfields/2712","display_name":"Endocrinology, Diabetes and Metabolism"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11018","display_name":"Lower Extremity Biomechanics and Pathologies","score":0.8190000057220459,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10455","display_name":"Foot and Ankle Surgery","score":0.7831000089645386,"subfield":{"id":"https://openalex.org/subfields/2732","display_name":"Orthopedics and Sports Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/goniometer","display_name":"Goniometer","score":0.9528883695602417},{"id":"https://openalex.org/keywords/ankle","display_name":"Ankle","score":0.6072031259536743},{"id":"https://openalex.org/keywords/sagittal-plane","display_name":"Sagittal plane","score":0.5915347337722778},{"id":"https://openalex.org/keywords/system-of-measurement","display_name":"System of measurement","score":0.5261982083320618},{"id":"https://openalex.org/keywords/tracking","display_name":"Tracking (education)","score":0.49767783284187317},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4931003749370575},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4773868918418884},{"id":"https://openalex.org/keywords/range-of-motion","display_name":"Range of motion","score":0.46822211146354675},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.44960951805114746},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.24139755964279175},{"id":"https://openalex.org/keywords/physical-therapy","display_name":"Physical therapy","score":0.18860840797424316},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.138082355260849},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.10503125190734863},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.08277919888496399}],"concepts":[{"id":"https://openalex.org/C48806519","wikidata":"https://www.wikidata.org/wiki/Q1126161","display_name":"Goniometer","level":2,"score":0.9528883695602417},{"id":"https://openalex.org/C2778640784","wikidata":"https://www.wikidata.org/wiki/Q168002","display_name":"Ankle","level":2,"score":0.6072031259536743},{"id":"https://openalex.org/C178910020","wikidata":"https://www.wikidata.org/wiki/Q2211994","display_name":"Sagittal plane","level":2,"score":0.5915347337722778},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.5261982083320618},{"id":"https://openalex.org/C2775936607","wikidata":"https://www.wikidata.org/wiki/Q466845","display_name":"Tracking (education)","level":2,"score":0.49767783284187317},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4931003749370575},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4773868918418884},{"id":"https://openalex.org/C60465272","wikidata":"https://www.wikidata.org/wiki/Q494478","display_name":"Range of motion","level":2,"score":0.46822211146354675},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.44960951805114746},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.24139755964279175},{"id":"https://openalex.org/C1862650","wikidata":"https://www.wikidata.org/wiki/Q186005","display_name":"Physical therapy","level":1,"score":0.18860840797424316},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.138082355260849},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.10503125190734863},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.08277919888496399},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C19417346","wikidata":"https://www.wikidata.org/wiki/Q7922","display_name":"Pedagogy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/wac.2018.8430462","is_oa":false,"landing_page_url":"https://doi.org/10.23919/wac.2018.8430462","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 World Automation Congress (WAC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2981969237","https://openalex.org/W1988801935","https://openalex.org/W46908530","https://openalex.org/W171732569","https://openalex.org/W2329806016","https://openalex.org/W2324649015","https://openalex.org/W2949820689","https://openalex.org/W1590839913","https://openalex.org/W4391118075","https://openalex.org/W2000081885"],"abstract_inverted_index":{"It":[0],"is":[1,11,25,40,50,60,69,100,115,138],"important":[2],"to":[3,15,71,116],"evaluate":[4],"the":[5,8,45,47,73,77,86,98,103,128,152,162,167,200],"function":[6],"of":[7,22,28,97,102,112],"foot,":[9],"which":[10],"an":[12,20,118],"essential":[13],"part":[14],"support":[16],"human":[17],"body.":[18],"As":[19],"index":[21],"evaluation,":[23,46],"there":[24],"ankle":[26,49,119],"range":[27],"motion":[29],"(ROM)":[30],"in":[31,108,132,158,165,171,181,195],"sagittal":[32],"plane.":[33],"In":[34,44,147],"current":[35],"clinical":[36],"situation,":[37],"this":[38,113,174],"evaluation":[39,58],"performed":[41],"using":[42,89,140],"goniometer.":[43,172],"patient":[48],"passively":[51],"moved":[52],"by":[53],"examiner":[54],"manual":[55,78,106],"force.":[56],"This":[57],"method":[59,88,130],"called":[61],"passive":[62,133],"ROM":[63,74,120],"test":[64],"(passive":[65],"ROM-T).":[66],"However,":[67],"it":[68,176],"difficult":[70],"measure":[72],"accurately":[75],"with":[76,123],"force,":[79],"and":[80,105,144,150,184,194],"several":[81],"studies":[82],"have":[83],"reported":[84],"that":[85,180],"measurement":[87,93,121,125,136],"a":[90],"goniometer":[91,131,193,197],"has":[92,188,198],"errors.":[94],"The":[95,110],"cause":[96],"error":[99],"difference":[101],"skill":[104],"force":[107,145],"examiner.":[109],"purpose":[111],"research":[114],"develop":[117],"system":[122,137,187],"higher":[124,189,199],"accuracy":[126],"than":[127,192,202],"conventional":[129],"ROM-T.":[134],"Our":[135],"developed":[139,159,186,203],"electromagnetic":[141],"tracking":[142],"device":[143],"sensor.":[146],"plantar":[148,182],"flexion":[149,183],"ROM,":[151,185],"standard":[153],"deviation":[154],"(SD)":[155],"was":[156,169],"smaller":[157,170],"system.":[160,204],"On":[161],"other":[163],"hand,":[164],"dorsiflexion,":[166,196],"SD":[168],"For":[173],"phenomenon,":[175],"can":[177],"be":[178],"said":[179],"intra-examiner":[190],"reliability":[191,201]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
