{"id":"https://openalex.org/W2980088320","doi":"https://doi.org/10.23919/sice.2019.8859967","title":"Verification of Medical Measuring Device on Therapeutic Ultrasound Using Metrological Traceability","display_name":"Verification of Medical Measuring Device on Therapeutic Ultrasound Using Metrological Traceability","publication_year":2019,"publication_date":"2019-09-01","ids":{"openalex":"https://openalex.org/W2980088320","doi":"https://doi.org/10.23919/sice.2019.8859967","mag":"2980088320"},"language":"en","primary_location":{"id":"doi:10.23919/sice.2019.8859967","is_oa":false,"landing_page_url":"https://doi.org/10.23919/sice.2019.8859967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021169731","display_name":"Patchariya Petchpong","orcid":null},"institutions":[{"id":"https://openalex.org/I4387152776","display_name":"National Institute of Metrology (Thailand)","ror":"https://ror.org/01357ty92","country_code":null,"type":"government","lineage":["https://openalex.org/I4387152776"]}],"countries":["TH"],"is_corresponding":true,"raw_author_name":"Patchariya Petchpong","raw_affiliation_strings":["Ultrasound Laboratory, National Institute of Metrology (Thailand), Pathumthani, Thailand"],"affiliations":[{"raw_affiliation_string":"Ultrasound Laboratory, National Institute of Metrology (Thailand), Pathumthani, Thailand","institution_ids":["https://openalex.org/I4387152776"]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5021169731"],"corresponding_institution_ids":["https://openalex.org/I4387152776"],"apc_list":null,"apc_paid":null,"fwci":0.1823,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.48756833,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"817","last_page":"822"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9843999743461609,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9628999829292297,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/traceability","display_name":"Traceability","score":0.9212532043457031},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6967638731002808},{"id":"https://openalex.org/keywords/therapeutic-ultrasound","display_name":"Therapeutic ultrasound","score":0.593054473400116},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.5607243776321411},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5322169065475464},{"id":"https://openalex.org/keywords/guideline","display_name":"Guideline","score":0.5251114964485168},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5182666778564453},{"id":"https://openalex.org/keywords/medical-physics","display_name":"Medical physics","score":0.4996974468231201},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.48400065302848816},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.43990665674209595},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.3401610553264618},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.29055607318878174},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2146642506122589},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12142175436019897},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.11829990148544312},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.11020070314407349},{"id":"https://openalex.org/keywords/software-engineering","display_name":"Software engineering","score":0.07983982563018799},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07824486494064331}],"concepts":[{"id":"https://openalex.org/C153876917","wikidata":"https://www.wikidata.org/wiki/Q899704","display_name":"Traceability","level":2,"score":0.9212532043457031},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6967638731002808},{"id":"https://openalex.org/C2779727089","wikidata":"https://www.wikidata.org/wiki/Q564875","display_name":"Therapeutic ultrasound","level":3,"score":0.593054473400116},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.5607243776321411},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5322169065475464},{"id":"https://openalex.org/C2780182762","wikidata":"https://www.wikidata.org/wiki/Q1630279","display_name":"Guideline","level":2,"score":0.5251114964485168},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5182666778564453},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.4996974468231201},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.48400065302848816},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.43990665674209595},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3401610553264618},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.29055607318878174},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2146642506122589},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12142175436019897},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.11829990148544312},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.11020070314407349},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.07983982563018799},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07824486494064331},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/sice.2019.8859967","is_oa":false,"landing_page_url":"https://doi.org/10.23919/sice.2019.8859967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7200000286102295,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W849075951","https://openalex.org/W2070151367","https://openalex.org/W2770793504","https://openalex.org/W2889349873","https://openalex.org/W4404398379"],"related_works":["https://openalex.org/W2378709054","https://openalex.org/W4380301954","https://openalex.org/W2803090313","https://openalex.org/W1482465488","https://openalex.org/W2052375654","https://openalex.org/W2376767034","https://openalex.org/W2077453531","https://openalex.org/W3209492875","https://openalex.org/W2011011149","https://openalex.org/W1670618853"],"abstract_inverted_index":{"Therapeutic":[0],"ultrasound":[1,91],"is":[2,42,95],"regularly":[3],"used":[4,96],"in":[5,20,61,88,135,195,207],"healthcare":[6],"system":[7],"with":[8,192,231],"the":[9,15,32,44,49,70,83,86,99,108,111,130,136,164,175,186,196,200,212,223,232,235,241],"aim":[10],"of":[11,17,23,28,34,39,46,52,78,102,118,167,171,209,215,222],"treatment":[12],"disease.":[13],"Considering,":[14],"significance":[16],"these":[18],"device":[19,54,224],"daily":[21],"activities":[22],"medical":[24,53],"professionals":[25],"and":[26,37,145,170],"impact":[27],"their":[29,40],"measurements":[30,41],"on":[31,55],"health":[33],"patients,":[35],"safety":[36],"accuracy":[38,242],"becoming":[43],"topic":[45],"interest.":[47],"Therefore,":[48],"testing":[50,77,112],"guideline":[51,64],"ultrasonic":[56],"physiotherapy":[57],"had":[58],"been":[59,228],"published":[60],"Thailand.":[62,89],"This":[63],"was":[65,114],"carried":[66,155],"out":[67,156],"to":[68,97,105,123,133,160,180],"develop":[69],"reference":[71],"procedure":[72,113],"for":[73],"acceptance":[74],"or":[75],"periodic":[76],"therapeutic":[79,103],"ultrasound,":[80],"which":[81,125,141,226],"meet":[82],"requirements":[84],"from":[85,157],"authorities":[87],"The":[90],"power":[92,101,137,188],"meter":[93],"(UPM)":[94],"investigate":[98],"actual":[100],"devices":[104],"be":[106,129,152,184,204,238],"confirmed":[107],"traceability.":[109],"Before":[110],"revealed,":[115],"two":[116],"categories":[117],"UPM":[119,236],"calibration":[120,144],"were":[121],"determined":[122,153,185],"confirm":[124],"proper":[126],"techniques":[127],"will":[128],"best":[131],"traceability":[132],"check":[134],"system.":[138],"Two":[139],"methods,":[140],"are":[142,218],"mass":[143,201],"radiation":[146],"force":[147],"balance":[148],"(RFB)":[149],"system,":[150],"shall":[151,237],"by":[154],"0.5":[158],"W":[159,162],"10":[161],"over":[163],"frequency":[165],"range":[166],"0.95":[168],"MHz":[169],"3":[172],"MHz.":[173],"From":[174],"results,":[176],"RFB":[177,216],"method":[178,202,217],"according":[179],"IEC":[181],"61161":[182],"can":[183,203],"output":[187],"at":[189],"desired":[190],"frequencies":[191],"various":[193],"powers":[194],"real":[197],"use,":[198],"whereas":[199],"calibrated":[205,239],"only":[206],"terms":[208],"power.":[210],"Moreover,":[211],"deviation":[213],"results":[214],"within":[219],"\u00b130%":[220],"tolerance":[221],"indication,":[225],"has":[227,240],"agreed":[229],"performance":[230],"criterion.":[233],"However,":[234],"of\u226410%.":[243]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-03-16T09:10:04.655348","created_date":"2025-10-10T00:00:00"}