{"id":"https://openalex.org/W4415179526","doi":"https://doi.org/10.23919/ecc65951.2025.11187271","title":"Fast Nonlinear Reference Governor for Overshoot Mitigation with an Application to Power Control of Grid-Connected Converters","display_name":"Fast Nonlinear Reference Governor for Overshoot Mitigation with an Application to Power Control of Grid-Connected Converters","publication_year":2025,"publication_date":"2025-06-24","ids":{"openalex":"https://openalex.org/W4415179526","doi":"https://doi.org/10.23919/ecc65951.2025.11187271"},"language":"en","primary_location":{"id":"doi:10.23919/ecc65951.2025.11187271","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc65951.2025.11187271","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017227182","display_name":"Amir Hossein Abolmasoumi","orcid":"https://orcid.org/0000-0001-9739-1340"},"institutions":[{"id":"https://openalex.org/I100445878","display_name":"\u00c9cole Centrale de Nantes","ror":"https://ror.org/03nh7d505","country_code":"FR","type":"education","lineage":["https://openalex.org/I100445878","https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Amir H. Abolmasoumi","raw_affiliation_strings":["Ecole Centrale de Nantes,Nantes,France"],"affiliations":[{"raw_affiliation_string":"Ecole Centrale de Nantes,Nantes,France","institution_ids":["https://openalex.org/I100445878"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080634313","display_name":"Bogdan Marinescu","orcid":"https://orcid.org/0000-0001-7378-9354"},"institutions":[{"id":"https://openalex.org/I100445878","display_name":"\u00c9cole Centrale de Nantes","ror":"https://ror.org/03nh7d505","country_code":"FR","type":"education","lineage":["https://openalex.org/I100445878","https://openalex.org/I97188460"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Bogdan Marinescu","raw_affiliation_strings":["Ecole Centrale de Nantes,Nantes,France"],"affiliations":[{"raw_affiliation_string":"Ecole Centrale de Nantes,Nantes,France","institution_ids":["https://openalex.org/I100445878"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5017227182"],"corresponding_institution_ids":["https://openalex.org/I100445878"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.39133754,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"969","last_page":"975"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.988099992275238,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9854999780654907,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.8138999938964844},{"id":"https://openalex.org/keywords/overshoot","display_name":"Overshoot (microwave communication)","score":0.6949999928474426},{"id":"https://openalex.org/keywords/governor","display_name":"Governor","score":0.5913000106811523},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.5702999830245972},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5422000288963318},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5030999779701233},{"id":"https://openalex.org/keywords/transfer-function","display_name":"Transfer function","score":0.3855000138282776},{"id":"https://openalex.org/keywords/inverse","display_name":"Inverse","score":0.38089999556541443}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.8138999938964844},{"id":"https://openalex.org/C2780323453","wikidata":"https://www.wikidata.org/wiki/Q7113957","display_name":"Overshoot (microwave communication)","level":2,"score":0.6949999928474426},{"id":"https://openalex.org/C2781233147","wikidata":"https://www.wikidata.org/wiki/Q3229617","display_name":"Governor","level":2,"score":0.5913000106811523},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.5702999830245972},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5422000288963318},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5037999749183655},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5030999779701233},{"id":"https://openalex.org/C81299745","wikidata":"https://www.wikidata.org/wiki/Q334269","display_name":"Transfer function","level":2,"score":0.3855000138282776},{"id":"https://openalex.org/C207467116","wikidata":"https://www.wikidata.org/wiki/Q4385666","display_name":"Inverse","level":2,"score":0.38089999556541443},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.3610000014305115},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3393999934196472},{"id":"https://openalex.org/C91581856","wikidata":"https://www.wikidata.org/wiki/Q2707001","display_name":"Nonlinear control","level":3,"score":0.3301999866962433},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.32749998569488525},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.30230000615119934},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.2896000146865845},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2847999930381775},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2815000116825104},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.27810001373291016},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.26420000195503235}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc65951.2025.11187271","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc65951.2025.11187271","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"A":[0],"novel":[1],"concept,":[2],"termed":[3],"the":[4,11,21,39,56,59,71,100,109,114],"conditioning":[5,18],"function,":[6,63],"is":[7,45,49,74],"introduced,":[8],"leading":[9],"to":[10,37,84,108],"development":[12],"of":[13,55,58,70,91],"a":[14,78,92],"new":[15],"nonlinear":[16],"reference":[17,23,42],"method":[19],"called":[20],"conditioning-function-based":[22,41],"governor":[24,43],"(CF-RG).":[25],"To":[26],"achieve":[27],"faster":[28],"and":[29,81],"more":[30],"efficient":[31],"responses,":[32],"an":[33,52,82,104],"enhanced":[34],"version,":[35],"referred":[36],"as":[38],"fast":[40],"(FCF-RG),":[44],"proposed.":[46],"This":[47],"technique":[48],"based":[50],"on":[51],"approximate":[53],"calculation":[54],"inverse":[57],"nominal":[60,110],"loop":[61],"transfer":[62],"allowing":[64],"for":[65],"rapid":[66],"adjustments.":[67],"The":[68,96],"effectiveness":[69],"proposed":[72,101],"methods":[73],"demonstrated":[75],"through":[76],"both":[77],"mathematical":[79],"example":[80],"application":[83],"overshoot":[85],"mitigation":[86],"in":[87],"active":[88],"power":[89],"control":[90],"three-phase":[93],"grid-connected":[94],"converter.":[95],"results":[97],"show":[98],"that":[99],"approaches":[102],"provide":[103],"additional":[105],"safety":[106],"layer":[107],"controller,":[111],"effectively":[112],"limiting":[113],"output.":[115]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-10-15T00:00:00"}