{"id":"https://openalex.org/W4415179615","doi":"https://doi.org/10.23919/ecc65951.2025.11186974","title":"A moving horizon estimator for aquifer thermal energy storages","display_name":"A moving horizon estimator for aquifer thermal energy storages","publication_year":2025,"publication_date":"2025-06-24","ids":{"openalex":"https://openalex.org/W4415179615","doi":"https://doi.org/10.23919/ecc65951.2025.11186974"},"language":"en","primary_location":{"id":"doi:10.23919/ecc65951.2025.11186974","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc65951.2025.11186974","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2504.10203","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5095740298","display_name":"Johannes van Randenborgh","orcid":"https://orcid.org/0009-0003-7881-1030"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Johannes van Randenborgh","raw_affiliation_strings":["TU Dortmund University,Control and Cyberphysical Systems Group, Faculty of Mechanical Engineering,Germany"],"affiliations":[{"raw_affiliation_string":"TU Dortmund University,Control and Cyberphysical Systems Group, Faculty of Mechanical Engineering,Germany","institution_ids":["https://openalex.org/I200332995"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073429393","display_name":"Moritz Schulze Darup","orcid":"https://orcid.org/0000-0002-1868-4098"},"institutions":[{"id":"https://openalex.org/I200332995","display_name":"TU Dortmund University","ror":"https://ror.org/01k97gp34","country_code":"DE","type":"education","lineage":["https://openalex.org/I200332995"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Moritz Schulze Darup","raw_affiliation_strings":["TU Dortmund University,Control and Cyberphysical Systems Group, Faculty of Mechanical Engineering,Germany"],"affiliations":[{"raw_affiliation_string":"TU Dortmund University,Control and Cyberphysical Systems Group, Faculty of Mechanical Engineering,Germany","institution_ids":["https://openalex.org/I200332995"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5095740298"],"corresponding_institution_ids":["https://openalex.org/I200332995"],"apc_list":null,"apc_paid":null,"fwci":0.3335,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.60423534,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"2690","last_page":"2696"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11225","display_name":"Geothermal Energy Systems and Applications","score":0.9158999919891357,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11225","display_name":"Geothermal Energy Systems and Applications","score":0.9158999919891357,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/aquifer","display_name":"Aquifer","score":0.772599995136261},{"id":"https://openalex.org/keywords/borehole","display_name":"Borehole","score":0.5412999987602234},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.47189998626708984},{"id":"https://openalex.org/keywords/estimator","display_name":"Estimator","score":0.4593000113964081},{"id":"https://openalex.org/keywords/horizon","display_name":"Horizon","score":0.45179998874664307},{"id":"https://openalex.org/keywords/groundwater","display_name":"Groundwater","score":0.3801000118255615},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3700000047683716},{"id":"https://openalex.org/keywords/clogging","display_name":"Clogging","score":0.34689998626708984}],"concepts":[{"id":"https://openalex.org/C75622301","wikidata":"https://www.wikidata.org/wiki/Q208791","display_name":"Aquifer","level":3,"score":0.772599995136261},{"id":"https://openalex.org/C150560799","wikidata":"https://www.wikidata.org/wiki/Q502102","display_name":"Borehole","level":2,"score":0.5412999987602234},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5004000067710876},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.47189998626708984},{"id":"https://openalex.org/C185429906","wikidata":"https://www.wikidata.org/wiki/Q1130160","display_name":"Estimator","level":2,"score":0.4593000113964081},{"id":"https://openalex.org/C159176650","wikidata":"https://www.wikidata.org/wiki/Q43261","display_name":"Horizon","level":2,"score":0.45179998874664307},{"id":"https://openalex.org/C76177295","wikidata":"https://www.wikidata.org/wiki/Q161598","display_name":"Groundwater","level":2,"score":0.3801000118255615},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3700000047683716},{"id":"https://openalex.org/C78762247","wikidata":"https://www.wikidata.org/wiki/Q1273174","display_name":"Petroleum engineering","level":1,"score":0.3610000014305115},{"id":"https://openalex.org/C2778152828","wikidata":"https://www.wikidata.org/wiki/Q488656","display_name":"Clogging","level":2,"score":0.34689998626708984},{"id":"https://openalex.org/C107861326","wikidata":"https://www.wikidata.org/wiki/Q209233","display_name":"Thermal energy","level":2,"score":0.3452000021934509},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.34380000829696655},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.3142000138759613},{"id":"https://openalex.org/C28761237","wikidata":"https://www.wikidata.org/wiki/Q7805321","display_name":"Time horizon","level":2,"score":0.31360000371932983},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2825999855995178},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.2809999883174896},{"id":"https://openalex.org/C76969082","wikidata":"https://www.wikidata.org/wiki/Q486902","display_name":"Mathematical model","level":2,"score":0.27730000019073486},{"id":"https://openalex.org/C129844170","wikidata":"https://www.wikidata.org/wiki/Q41299","display_name":"Quadratic equation","level":2,"score":0.2743000090122223},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.2694000005722046},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.2551000118255615},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.2542000114917755},{"id":"https://openalex.org/C176650113","wikidata":"https://www.wikidata.org/wiki/Q370689","display_name":"Groundwater model","level":5,"score":0.2538999915122986}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.23919/ecc65951.2025.11186974","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc65951.2025.11186974","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 European Control Conference (ECC)","raw_type":"proceedings-article"},{"id":"pmh:oai:arXiv.org:2504.10203","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2504.10203","pdf_url":"https://arxiv.org/pdf/2504.10203","source":{"id":"https://openalex.org/S4393918464","display_name":"ArXiv.org","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2504.10203","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2504.10203","pdf_url":"https://arxiv.org/pdf/2504.10203","source":{"id":"https://openalex.org/S4393918464","display_name":"ArXiv.org","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W124016759","https://openalex.org/W134696702","https://openalex.org/W644084929","https://openalex.org/W1651676304","https://openalex.org/W1977985274","https://openalex.org/W2022151692","https://openalex.org/W2120619614","https://openalex.org/W2138280264","https://openalex.org/W2146904562","https://openalex.org/W2557999854","https://openalex.org/W2562854303","https://openalex.org/W2749680651","https://openalex.org/W2765206877","https://openalex.org/W2790374560","https://openalex.org/W2801772336","https://openalex.org/W3090789943","https://openalex.org/W4229786028","https://openalex.org/W4243369158","https://openalex.org/W4246038204","https://openalex.org/W4298007820","https://openalex.org/W4390985938","https://openalex.org/W4402837785"],"related_works":[],"abstract_inverted_index":{"Aquifer":[0],"thermal":[1,11,28],"energy":[2,12,29],"storages":[3],"(ATES)":[4],"represent":[5],"groundwater":[6,106],"saturated":[7],"aquifers":[8],"that":[9],"store":[10],"in":[13],"the":[14,38,55,68,92,113,116,120,128,131,144,153,163,167],"form":[15],"of":[16,52,71,115,119,130,146,166],"heated":[17],"or":[18],"cooled":[19],"groundwater.":[20],"Combining":[21],"two":[22],"ATES,":[23],"one":[24],"can":[25],"harness":[26],"excess":[27],"from":[30],"summer":[31],"(heat)":[32],"and":[33,42,66,171],"winter":[34],"(cold)":[35],"to":[36,59,103,161],"support":[37],"building\u2019s":[39],"heating,":[40],"ventilation,":[41],"air":[43],"conditioning":[44],"(HVAC)":[45],"technology.":[46],"In":[47,133],"general,":[48],"a":[49,84,180],"dynamic":[50],"operation":[51],"ATES":[53,89,148,169],"throughout":[54],"year":[56],"is":[57,136,150,155],"beneficial":[58],"avoid":[60],"using":[61],"fossil":[62],"fuel-based":[63],"HVAC":[64],"technology":[65],"maximize":[67],"\"green":[69],"use\"":[70],"ATES.":[72,132],"Model":[73],"predictive":[74],"control":[75,86],"(MPC)":[76],"with":[77],"an":[78,147,173],"appropriate":[79],"system":[80,149],"model":[81,94,154,170],"may":[82],"become":[83],"crucial":[85],"approach":[87],"for":[88],"systems.":[90],"Consequently,":[91],"MPC":[93],"should":[95],"reflect":[96],"spatial":[97],"temperature":[98],"profiles":[99],"around":[100],"ATES\u2019":[101],"boreholes":[102],"predict":[104],"extracted":[105],"temperatures":[107],"accurately.":[108],"However,":[109],"meaningful":[110],"predictions":[111],"require":[112],"estimation":[114],"current":[117],"state":[118,145],"system,":[121],"as":[122],"measurements":[123],"are":[124],"usually":[125],"only":[126],"at":[127],"borehole":[129],"control,":[134],"this":[135],"often":[137],"realized":[138],"by":[139],"model-based":[140],"observers.":[141],"Still,":[142],"observing":[143],"non-trivial,":[151],"since":[152],"typically":[156],"hybrid.":[157],"We":[158],"show":[159],"how":[160],"exploit":[162],"specific":[164],"structure":[165],"hybrid":[168],"design":[172],"easy-to-solve":[174],"moving":[175],"horizon":[176],"estimator":[177],"based":[178],"on":[179],"quadratic":[181],"program.":[182]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-04-17T18:11:37.981687","created_date":"2025-10-15T00:00:00"}
