{"id":"https://openalex.org/W2903044744","doi":"https://doi.org/10.23919/ecc.2018.8550395","title":"Robust voltage regulation of boost converters in DC microgrids","display_name":"Robust voltage regulation of boost converters in DC microgrids","publication_year":2018,"publication_date":"2018-06-01","ids":{"openalex":"https://openalex.org/W2903044744","doi":"https://doi.org/10.23919/ecc.2018.8550395","mag":"2903044744"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.2018.8550395","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2018.8550395","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://pure.rug.nl/ws/files/77591711/08550395_1_.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039988381","display_name":"Michele Cucuzzella","orcid":"https://orcid.org/0000-0003-1677-3289"},"institutions":[{"id":"https://openalex.org/I169381384","display_name":"University of Groningen","ror":"https://ror.org/012p63287","country_code":"NL","type":"education","lineage":["https://openalex.org/I169381384"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Michele Cucuzzella","raw_affiliation_strings":["Jan C. Willems Center for Systems and Control, ENTEG Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, AG, Groningen Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Jan C. Willems Center for Systems and Control, ENTEG Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, AG, Groningen Netherlands","institution_ids":["https://openalex.org/I169381384"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024003663","display_name":"Riccardo Lazzari","orcid":"https://orcid.org/0000-0002-3441-4784"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Riccardo Lazzari","raw_affiliation_strings":["Department of Power Generation Technologies, Materials RSE S.p.A., via Rubattino Raffaele 54, Milan, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Generation Technologies, Materials RSE S.p.A., via Rubattino Raffaele 54, Milan, Italy","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067013904","display_name":"Sebastian Trip","orcid":"https://orcid.org/0000-0002-6766-6857"},"institutions":[{"id":"https://openalex.org/I169381384","display_name":"University of Groningen","ror":"https://ror.org/012p63287","country_code":"NL","type":"education","lineage":["https://openalex.org/I169381384"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Sebastian Trip","raw_affiliation_strings":["Jan C. Willems Center for Systems and Control, ENTEG Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, AG, Groningen Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Jan C. Willems Center for Systems and Control, ENTEG Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, AG, Groningen Netherlands","institution_ids":["https://openalex.org/I169381384"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Carlo Sandroni","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Carlo Sandroni","raw_affiliation_strings":["Department of Power Generation Technologies, Materials RSE S.p.A., via Rubattino Raffaele 54, Milan, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Generation Technologies, Materials RSE S.p.A., via Rubattino Raffaele 54, Milan, Italy","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073649425","display_name":"Antonella Ferrara","orcid":"https://orcid.org/0000-0002-1977-8248"},"institutions":[{"id":"https://openalex.org/I25217355","display_name":"University of Pavia","ror":"https://ror.org/00s6t1f81","country_code":"IT","type":"education","lineage":["https://openalex.org/I25217355"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Antonella Ferrara","raw_affiliation_strings":["Dipartimento di Ingegneria Industriale e dell\u2019Informazione, University of Pavia via Ferrata 5, Pavia, Italy","Dipartimento di Ingegneria Industriale e dell'Informazione, University of Pavia via Ferrata 5, Pavia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Ingegneria Industriale e dell\u2019Informazione, University of Pavia via Ferrata 5, Pavia, Italy","institution_ids":["https://openalex.org/I25217355"]},{"raw_affiliation_string":"Dipartimento di Ingegneria Industriale e dell'Informazione, University of Pavia via Ferrata 5, Pavia, Italy","institution_ids":["https://openalex.org/I25217355"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1873,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.53143,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"2350","last_page":"2355"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.991100013256073,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9412479400634766},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.8173680305480957},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6895892024040222},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5809578895568848},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5447510480880737},{"id":"https://openalex.org/keywords/robust-control","display_name":"Robust control","score":0.5204260945320129},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.47277215123176575},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.4665403664112091},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.46238890290260315},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.4606630206108093},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.35792776942253113},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3342908024787903},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.2256496548652649},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1255578100681305},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09388807415962219}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9412479400634766},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.8173680305480957},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6895892024040222},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5809578895568848},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5447510480880737},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.5204260945320129},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47277215123176575},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.4665403664112091},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.46238890290260315},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.4606630206108093},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35792776942253113},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3342908024787903},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2256496548652649},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1255578100681305},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09388807415962219},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.23919/ecc.2018.8550395","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2018.8550395","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 European Control Conference (ECC)","raw_type":"proceedings-article"},{"id":"pmh:oai:pure.rug.nl:publications/dff27e01-8e2a-4cfe-8598-77dfbc71aa3c","is_oa":true,"landing_page_url":"https://research.rug.nl/en/publications/dff27e01-8e2a-4cfe-8598-77dfbc71aa3c","pdf_url":"https://pure.rug.nl/ws/files/77591711/08550395_1_.pdf","source":{"id":"https://openalex.org/S4306400420","display_name":"University of Groningen research database (University of Groningen / Centre for Information Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169381384","host_organization_name":"University of Groningen","host_organization_lineage":["https://openalex.org/I169381384"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Cucuzzella, M, Lazzari, R, Trip, S, Sandroni, C & Ferrara, A 2018, Robust voltage regulation of boost converters in DC microgrids. in Proceedings of the European Control Conference 2018. EUCA, European Control Conference 2018 (ECC 2018), Limassol, Cyprus, 12/06/2018. https://doi.org/10.23919/ECC.2018.8550395","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"pmh:oai:pure.rug.nl:publications/dff27e01-8e2a-4cfe-8598-77dfbc71aa3c","is_oa":true,"landing_page_url":"https://research.rug.nl/en/publications/dff27e01-8e2a-4cfe-8598-77dfbc71aa3c","pdf_url":"https://pure.rug.nl/ws/files/77591711/08550395_1_.pdf","source":{"id":"https://openalex.org/S4306400420","display_name":"University of Groningen research database (University of Groningen / Centre for Information Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169381384","host_organization_name":"University of Groningen","host_organization_lineage":["https://openalex.org/I169381384"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Cucuzzella, M, Lazzari, R, Trip, S, Sandroni, C & Ferrara, A 2018, Robust voltage regulation of boost converters in DC microgrids. in Proceedings of the European Control Conference 2018. EUCA, European Control Conference 2018 (ECC 2018), Limassol, Cyprus, 12/06/2018. https://doi.org/10.23919/ECC.2018.8550395","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8399999737739563}],"awards":[{"id":"https://openalex.org/G8934829050","display_name":null,"funder_award_id":"408.urs+.16.005","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"}],"funders":[{"id":"https://openalex.org/F4320321800","display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","ror":"https://ror.org/04jsz6e67"},{"id":"https://openalex.org/F4320324632","display_name":"Ministero dello Sviluppo Economico","ror":"https://ror.org/011z3ff80"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2903044744.pdf","grobid_xml":"https://content.openalex.org/works/W2903044744.grobid-xml"},"referenced_works_count":28,"referenced_works":["https://openalex.org/W267271646","https://openalex.org/W1516289514","https://openalex.org/W1977464588","https://openalex.org/W1990833963","https://openalex.org/W2003200910","https://openalex.org/W2011866185","https://openalex.org/W2032098152","https://openalex.org/W2084943452","https://openalex.org/W2095984659","https://openalex.org/W2111018365","https://openalex.org/W2111176322","https://openalex.org/W2127761430","https://openalex.org/W2136236807","https://openalex.org/W2186178845","https://openalex.org/W2235799085","https://openalex.org/W2265937691","https://openalex.org/W2295386022","https://openalex.org/W2488057134","https://openalex.org/W2506768803","https://openalex.org/W2606065717","https://openalex.org/W2607227935","https://openalex.org/W2737875000","https://openalex.org/W2783315201","https://openalex.org/W2791578439","https://openalex.org/W2886325924","https://openalex.org/W2962910558","https://openalex.org/W2963497702","https://openalex.org/W6696972846"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W4210780382","https://openalex.org/W2356033827","https://openalex.org/W2391138633","https://openalex.org/W4206134051","https://openalex.org/W2907234787","https://openalex.org/W4285503559","https://openalex.org/W4383747562"],"abstract_inverted_index":{"This":[0],"paper":[1],"deals":[2],"with":[3],"the":[4,24,56,59,77],"design":[5,25],"of":[6,23,26,39,58,76],"a":[7,27,90],"robust":[8],"decentralized":[9],"control":[10,51,67,82],"scheme":[11,83],"for":[12],"voltage":[13,32],"regulation":[14,33],"in":[15,37],"boost-based":[16],"DC":[17,92],"microgrids.":[18],"The":[19,80],"proposed":[20,81],"solution":[21],"consists":[22],"suitable":[28],"manifold":[29,63],"on":[30,89],"which":[31],"is":[34,52],"achieved,":[35],"even":[36],"presence":[38],"unknown":[40],"load":[41],"demand":[42],"and":[43],"modelling":[44],"uncertainties.":[45],"A":[46],"second":[47],"order":[48],"sliding":[49],"mode":[50],"used":[53,72],"to":[54,61],"constrain":[55],"state":[57],"microgrid":[60],"this":[62],"by":[64],"generating":[65],"continuous":[66],"inputs":[68],"that":[69],"can":[70],"be":[71],"as":[73],"duty":[74],"cycles":[75],"power":[78],"converters.":[79],"has":[84],"been":[85],"validated":[86],"through":[87],"experiments":[88],"real":[91],"microgrid.":[93]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
