{"id":"https://openalex.org/W1767650485","doi":"https://doi.org/10.23919/ecc.2013.6669647","title":"Dynamic power coordination for load reduction in dispatchable wind power plants","display_name":"Dynamic power coordination for load reduction in dispatchable wind power plants","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W1767650485","doi":"https://doi.org/10.23919/ecc.2013.6669647","mag":"1767650485"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.2013.6669647","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2013.6669647","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071311372","display_name":"Daria Madjidian","orcid":"https://orcid.org/0000-0003-4762-6310"},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Daria Madjidian","raw_affiliation_strings":["Department of Automatic Control, Lund Univesity, Sweden","[Dept. of Autom. Control, Lund Univ., Lund, Sweden]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control, Lund Univesity, Sweden","institution_ids":[]},{"raw_affiliation_string":"[Dept. of Autom. Control, Lund Univ., Lund, Sweden]","institution_ids":["https://openalex.org/I187531555"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022005236","display_name":"Maxim Kristalny","orcid":null},"institutions":[{"id":"https://openalex.org/I174306211","display_name":"Technion \u2013 Israel Institute of Technology","ror":"https://ror.org/03qryx823","country_code":"IL","type":"education","lineage":["https://openalex.org/I174306211"]}],"countries":["IL"],"is_corresponding":false,"raw_author_name":"Maxim Kristalny","raw_affiliation_strings":["Department of Mechanical Engineering, Technion-IIT, Haifa, Israel","Dept. of Mech. Eng., Technion-Israel Inst. of Technol., Haifa, Israel"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Technion-IIT, Haifa, Israel","institution_ids":["https://openalex.org/I174306211"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Technion-Israel Inst. of Technol., Haifa, Israel","institution_ids":["https://openalex.org/I174306211"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091667471","display_name":"Anders Rantzer","orcid":"https://orcid.org/0000-0001-7118-2786"},"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]}],"countries":["SE"],"is_corresponding":false,"raw_author_name":"Anders Rantzer","raw_affiliation_strings":["Department of Automatic Control, Lund Univesity, Sweden","[Dept. of Autom. Control, Lund Univ., Lund, Sweden]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automatic Control, Lund Univesity, Sweden","institution_ids":[]},{"raw_affiliation_string":"[Dept. of Autom. Control, Lund Univ., Lund, Sweden]","institution_ids":["https://openalex.org/I187531555"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4318,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.87953659,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"3554","last_page":"3559"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10680","display_name":"Wind Energy Research and Development","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dispatchable-generation","display_name":"Dispatchable generation","score":0.9479809999465942},{"id":"https://openalex.org/keywords/base-load-power-plant","display_name":"Base load power plant","score":0.7876262068748474},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6534914970397949},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.635158121585846},{"id":"https://openalex.org/keywords/dynamic-demand","display_name":"Dynamic demand","score":0.6292474269866943},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.6225498914718628},{"id":"https://openalex.org/keywords/reduction","display_name":"Reduction (mathematics)","score":0.5112156867980957},{"id":"https://openalex.org/keywords/peaking-power-plant","display_name":"Peaking power plant","score":0.4795341491699219},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4604869484901428},{"id":"https://openalex.org/keywords/power-station","display_name":"Power station","score":0.45356959104537964},{"id":"https://openalex.org/keywords/tower","display_name":"Tower","score":0.4194222092628479},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3982178866863251},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.37025296688079834},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3518989682197571},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3417757749557495},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.3237890303134918},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.23735973238945007},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.14958849549293518},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.10347506403923035},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.0935451090335846},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.07721436023712158}],"concepts":[{"id":"https://openalex.org/C85924503","wikidata":"https://www.wikidata.org/wiki/Q5282546","display_name":"Dispatchable generation","level":4,"score":0.9479809999465942},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.7876262068748474},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6534914970397949},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.635158121585846},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.6292474269866943},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.6225498914718628},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.5112156867980957},{"id":"https://openalex.org/C154594046","wikidata":"https://www.wikidata.org/wiki/Q18979989","display_name":"Peaking power plant","level":4,"score":0.4795341491699219},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4604869484901428},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.45356959104537964},{"id":"https://openalex.org/C2777831296","wikidata":"https://www.wikidata.org/wiki/Q12518","display_name":"Tower","level":2,"score":0.4194222092628479},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3982178866863251},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.37025296688079834},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3518989682197571},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3417757749557495},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.3237890303134918},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23735973238945007},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14958849549293518},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.10347506403923035},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0935451090335846},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.07721436023712158},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc.2013.6669647","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2013.6669647","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320322581","display_name":"Vetenskapsr\u00e5det","ror":"https://ror.org/03zttf063"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W23461024","https://openalex.org/W98496564","https://openalex.org/W1533975523","https://openalex.org/W1857498091","https://openalex.org/W1966750171","https://openalex.org/W1976174271","https://openalex.org/W1977430896","https://openalex.org/W2004119345","https://openalex.org/W2006772024","https://openalex.org/W2042597173","https://openalex.org/W2045427092","https://openalex.org/W2056293444","https://openalex.org/W2081468738","https://openalex.org/W2109042644","https://openalex.org/W2110684439","https://openalex.org/W2113053916","https://openalex.org/W2119140621","https://openalex.org/W2128990323","https://openalex.org/W2181809926","https://openalex.org/W2538768088","https://openalex.org/W2891553636"],"related_works":["https://openalex.org/W2135154885","https://openalex.org/W3181163419","https://openalex.org/W2473400489","https://openalex.org/W2010567603","https://openalex.org/W92211312","https://openalex.org/W2794465098","https://openalex.org/W5025596","https://openalex.org/W1767650485","https://openalex.org/W2416810777","https://openalex.org/W3159717474"],"abstract_inverted_index":{"In":[0,75],"a":[1],"dispatchable":[2],"wind":[3],"power":[4,13,26,59],"plant,":[5],"turbines":[6,44],"are":[7],"free":[8],"to":[9,38,48],"continuously":[10],"vary":[11],"their":[12,21,50],"production":[14],"as":[15,17],"long":[16],"the":[18,24,46,55,67,71,79],"sum":[19],"of":[20,81],"productions":[22],"meets":[23],"total":[25],"demand.":[27],"Previous":[28],"research":[29],"has":[30],"shown":[31],"that":[32,57],"this":[33],"freedom":[34],"can":[35],"be":[36],"used":[37],"reduce":[39],"structural":[40,64],"loads":[41,65],"by":[42],"allowing":[43],"in":[45],"plant":[47],"coordinate":[49],"power.":[51],"This":[52],"paper":[53],"explains":[54],"mechanisms":[56],"make":[58],"coordination":[60,82],"useful":[61],"for":[62],"reducing":[63],"on":[66],"turbine":[68],"tower":[69],"and":[70],"low":[72],"speed":[73],"shaft.":[74],"addition,":[76],"it":[77],"assesses":[78],"benefits":[80],"at":[83],"different":[84],"operating":[85],"points.":[86]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
