{"id":"https://openalex.org/W1543292044","doi":"https://doi.org/10.23919/ecc.2013.6669438","title":"Soft sensor based dynamic flow rate estimation in low speed radial pumps","display_name":"Soft sensor based dynamic flow rate estimation in low speed radial pumps","publication_year":2013,"publication_date":"2013-07-01","ids":{"openalex":"https://openalex.org/W1543292044","doi":"https://doi.org/10.23919/ecc.2013.6669438","mag":"1543292044"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.2013.6669438","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2013.6669438","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5080925348","display_name":"Sebastian Leonow","orcid":"https://orcid.org/0000-0003-0489-8834"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Sebastian Leonow","raw_affiliation_strings":["Dep. of Mechanical Engineering, Ruhr-Universit\u00e4t Bochum","Dept. of Mech. Eng., Ruhr-Univ. Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Dep. of Mechanical Engineering, Ruhr-Universit\u00e4t Bochum","institution_ids":["https://openalex.org/I904495901"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Ruhr-Univ. Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058837549","display_name":"Martin M\u00f6nnigmann","orcid":"https://orcid.org/0000-0002-9277-2061"},"institutions":[{"id":"https://openalex.org/I904495901","display_name":"Ruhr University Bochum","ror":"https://ror.org/04tsk2644","country_code":"DE","type":"education","lineage":["https://openalex.org/I904495901"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Monnigmann","raw_affiliation_strings":["Dep. of Mechanical Engineering, Ruhr-Universit\u00e4t Bochum","Dept. of Mech. Eng., Ruhr-Univ. Bochum, Bochum, Germany"],"affiliations":[{"raw_affiliation_string":"Dep. of Mechanical Engineering, Ruhr-Universit\u00e4t Bochum","institution_ids":["https://openalex.org/I904495901"]},{"raw_affiliation_string":"Dept. of Mech. Eng., Ruhr-Univ. Bochum, Bochum, Germany","institution_ids":["https://openalex.org/I904495901"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5080925348"],"corresponding_institution_ids":["https://openalex.org/I904495901"],"apc_list":null,"apc_paid":null,"fwci":2.8992,"has_fulltext":false,"cited_by_count":20,"citation_normalized_percentile":{"value":0.89312179,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"778","last_page":"783"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11372","display_name":"Hydraulic and Pneumatic Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11081","display_name":"Advanced Control Systems Design","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6161484718322754},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5688799023628235},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.5630253553390503},{"id":"https://openalex.org/keywords/flow-control","display_name":"Flow control (data)","score":0.4977860450744629},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.48066580295562744},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.45799121260643005},{"id":"https://openalex.org/keywords/centrifugal-pump","display_name":"Centrifugal pump","score":0.45137399435043335},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4428146183490753},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.41171154379844666},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3959306478500366},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27987828850746155},{"id":"https://openalex.org/keywords/impeller","display_name":"Impeller","score":0.1492074429988861},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1458016037940979},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1295609474182129},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.11146610975265503}],"concepts":[{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6161484718322754},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5688799023628235},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.5630253553390503},{"id":"https://openalex.org/C186766456","wikidata":"https://www.wikidata.org/wiki/Q612457","display_name":"Flow control (data)","level":2,"score":0.4977860450744629},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.48066580295562744},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.45799121260643005},{"id":"https://openalex.org/C166675230","wikidata":"https://www.wikidata.org/wiki/Q627111","display_name":"Centrifugal pump","level":3,"score":0.45137399435043335},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4428146183490753},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.41171154379844666},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3959306478500366},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27987828850746155},{"id":"https://openalex.org/C153005164","wikidata":"https://www.wikidata.org/wiki/Q1698700","display_name":"Impeller","level":2,"score":0.1492074429988861},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1458016037940979},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1295609474182129},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11146610975265503},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc.2013.6669438","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2013.6669438","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320309954","display_name":"Deutsche Bundesstiftung Umwelt","ror":"https://ror.org/05pmq5w14"},{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1531716337","https://openalex.org/W1876493254","https://openalex.org/W1981247741","https://openalex.org/W2009518490","https://openalex.org/W2082450742","https://openalex.org/W2110900178","https://openalex.org/W2118187575","https://openalex.org/W2132642717","https://openalex.org/W2154712258","https://openalex.org/W2169469786","https://openalex.org/W4250418432"],"related_works":["https://openalex.org/W2005356353","https://openalex.org/W414409097","https://openalex.org/W2393015210","https://openalex.org/W2381089711","https://openalex.org/W3162034484","https://openalex.org/W4366779835","https://openalex.org/W2008882812","https://openalex.org/W2391419890","https://openalex.org/W2975433894","https://openalex.org/W2113804334"],"abstract_inverted_index":{"Today,":[0],"poorly":[1],"controlled":[2],"low":[3],"power":[4],"centrifugal":[5],"pumps":[6],"are":[7,46],"responsible":[8],"for":[9,114],"a":[10,77,109,120],"great":[11],"fraction":[12],"of":[13,93],"the":[14,21,29,94,106,111,115],"overall":[15],"pump":[16],"related":[17],"energy":[18,30],"consumption":[19],"in":[20,70],"European":[22],"Union":[23],"[1].":[24],"It":[25],"is":[26,57,117],"expected":[27],"that":[28],"efficiency":[31],"can":[32,101],"be":[33,102],"improved":[34],"considerably":[35],"with":[36],"appropriate":[37],"automatic":[38,85],"flow":[39,43,65,79],"rate":[40,44,66,80],"control.":[41],"Automatic":[42],"controllers":[45],"not":[47],"popular":[48],"among":[49],"practitioners,":[50],"however,":[51],"since":[52,62],"their":[53],"installation":[54],"and":[55,61,97],"tuning":[56],"an":[58,71],"additional":[59,112],"effort,":[60],"they":[63],"require":[64],"sensors,":[67],"which":[68,83],"result":[69],"increased":[72],"unit":[73],"cost.":[74],"We":[75],"present":[76],"dynamic":[78],"estimation":[81,95],"method":[82,96],"makes":[84],"control":[86],"without":[87],"traditional":[88],"sensors":[89],"possible.":[90],"The":[91],"setup":[92],"all":[98],"required":[99],"measurements":[100],"carried":[103],"out":[104],"by":[105],"manufacturer.":[107],"As":[108],"result,":[110],"effort":[113],"customer":[116],"kept":[118],"to":[119],"minimum.":[121]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1}],"updated_date":"2026-04-04T06:10:10.580331","created_date":"2025-10-10T00:00:00"}
