{"id":"https://openalex.org/W1587235572","doi":"https://doi.org/10.23919/ecc.2001.7076153","title":"Fuzzy neural network based diagnostic system application for three-tank system","display_name":"Fuzzy neural network based diagnostic system application for three-tank system","publication_year":2001,"publication_date":"2001-09-01","ids":{"openalex":"https://openalex.org/W1587235572","doi":"https://doi.org/10.23919/ecc.2001.7076153","mag":"1587235572"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.2001.7076153","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2001.7076153","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2001 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066589199","display_name":"Micha\u0142 Syfert","orcid":"https://orcid.org/0000-0001-7741-607X"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"M. Syfert","raw_affiliation_strings":["Institute of Automatic Control and Robotics, Warsaw University of Technology ul. Chodkiewicza 8, 02-525 Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Automatic Control and Robotics, Warsaw University of Technology ul. Chodkiewicza 8, 02-525 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000883886","display_name":"Jan Maciej Ko\u015bcielny","orcid":"https://orcid.org/0000-0002-8947-2025"},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"J. M. Koscielny","raw_affiliation_strings":["Institute of Automatic Control and Robotics, Warsaw University of Technology ul. Chodkiewicza 8, 02-525 Warsaw, Poland"],"affiliations":[{"raw_affiliation_string":"Institute of Automatic Control and Robotics, Warsaw University of Technology ul. Chodkiewicza 8, 02-525 Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5066589199"],"corresponding_institution_ids":["https://openalex.org/I108403487"],"apc_list":null,"apc_paid":null,"fwci":7.8653,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.96360541,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1631","last_page":"1636"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10820","display_name":"Fuzzy Logic and Control Systems","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9911999702453613,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7863103151321411},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.7327965497970581},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6699844002723694},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.6517239809036255},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.606406033039093},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.5987716317176819},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5861226916313171},{"id":"https://openalex.org/keywords/neuro-fuzzy","display_name":"Neuro-fuzzy","score":0.5689727663993835},{"id":"https://openalex.org/keywords/relation","display_name":"Relation (database)","score":0.5396511554718018},{"id":"https://openalex.org/keywords/fuzzy-control-system","display_name":"Fuzzy control system","score":0.4916279911994934},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.4546416997909546},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.42262566089630127},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34761908650398254},{"id":"https://openalex.org/keywords/data-mining","display_name":"Data mining","score":0.3079698979854584},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.08845311403274536},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.048825353384017944}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7863103151321411},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.7327965497970581},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6699844002723694},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.6517239809036255},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.606406033039093},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.5987716317176819},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5861226916313171},{"id":"https://openalex.org/C29470771","wikidata":"https://www.wikidata.org/wiki/Q4165150","display_name":"Neuro-fuzzy","level":4,"score":0.5689727663993835},{"id":"https://openalex.org/C25343380","wikidata":"https://www.wikidata.org/wiki/Q277521","display_name":"Relation (database)","level":2,"score":0.5396511554718018},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.4916279911994934},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4546416997909546},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.42262566089630127},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34761908650398254},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.3079698979854584},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.08845311403274536},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.048825353384017944},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc.2001.7076153","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2001.7076153","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2001 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W111632141","https://openalex.org/W1540378271","https://openalex.org/W1557923305","https://openalex.org/W2619103574","https://openalex.org/W2620102006","https://openalex.org/W2675056802"],"related_works":["https://openalex.org/W2560215812","https://openalex.org/W4385301753","https://openalex.org/W3186428265","https://openalex.org/W2171501125","https://openalex.org/W2617234683","https://openalex.org/W2375947351","https://openalex.org/W3207109968","https://openalex.org/W2133615482","https://openalex.org/W829773823","https://openalex.org/W2937114745"],"abstract_inverted_index":{"The":[0],"paper":[1],"presents":[2],"the":[3,22,41,48,57],"idea":[4],"of":[5,21,43,47,59],"fault":[6,28,37],"detection":[7,29],"and":[8,31,36],"isolation":[9,38],"(FDI)":[10],"system":[11,50,61],"based":[12],"on":[13,40,56],"fuzzy":[14,33],"neural":[15],"network":[16],"(FNN).":[17],"One":[18],"proposed":[19],"utilisation":[20],"FNN":[23],"both":[24],"to":[25,32],"modelling":[26],"for":[27],"purposes":[30],"residual":[34],"evaluation":[35],"performed":[39],"grounds":[42],"symptoms-faults":[44],"relation.":[45],"Properties":[46],"diagnostic":[49],"with":[51],"considered":[52],"structured":[53],"are":[54],"illustrated":[55],"example":[58],"three-tank":[60],"(TTS).":[62]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
