{"id":"https://openalex.org/W1597668237","doi":"https://doi.org/10.23919/ecc.2001.7075954","title":"A model based fault detection and diagnosis system for rolling mill equipments","display_name":"A model based fault detection and diagnosis system for rolling mill equipments","publication_year":2001,"publication_date":"2001-09-01","ids":{"openalex":"https://openalex.org/W1597668237","doi":"https://doi.org/10.23919/ecc.2001.7075954","mag":"1597668237"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.2001.7075954","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2001.7075954","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2001 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033167180","display_name":"M. Orchard","orcid":null},"institutions":[{"id":"https://openalex.org/I162148367","display_name":"Pontificia Universidad Cat\u00f3lica de Chile","ror":"https://ror.org/04teye511","country_code":"CL","type":"education","lineage":["https://openalex.org/I162148367"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Marcos C. Orchard","raw_affiliation_strings":["Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile","institution_ids":["https://openalex.org/I162148367"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109879508","display_name":"Aldo M. Cipriano","orcid":null},"institutions":[{"id":"https://openalex.org/I162148367","display_name":"Pontificia Universidad Cat\u00f3lica de Chile","ror":"https://ror.org/04teye511","country_code":"CL","type":"education","lineage":["https://openalex.org/I162148367"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Aldo M. Cipriano","raw_affiliation_strings":["Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile","institution_ids":["https://openalex.org/I162148367"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049925567","display_name":"Aldo Cipriano","orcid":"https://orcid.org/0000-0002-6516-9646"},"institutions":[{"id":"https://openalex.org/I162148367","display_name":"Pontificia Universidad Cat\u00f3lica de Chile","ror":"https://ror.org/04teye511","country_code":"CL","type":"education","lineage":["https://openalex.org/I162148367"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Aldo Z. Cipriano","raw_affiliation_strings":["Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile","institution_ids":["https://openalex.org/I162148367"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089480402","display_name":"Mariana Viale","orcid":"https://orcid.org/0000-0003-0590-0561"},"institutions":[{"id":"https://openalex.org/I162148367","display_name":"Pontificia Universidad Cat\u00f3lica de Chile","ror":"https://ror.org/04teye511","country_code":"CL","type":"education","lineage":["https://openalex.org/I162148367"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Mariana Viale","raw_affiliation_strings":["Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Pontificia Universidad Cat&#x00F3;lica de Chile, P.O. Box 306, Santiago 22, Chile","institution_ids":["https://openalex.org/I162148367"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080059903","display_name":"Andr\u00e9s Vigliocco","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Andr\u00e9s Vigliocco","raw_affiliation_strings":["SIDERAR S.A. Planta Gral. Savio (2900) San Nicol&#x00E1;s, Argentina"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SIDERAR S.A. Planta Gral. Savio (2900) San Nicol&#x00E1;s, Argentina","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.7651,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.80597992,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"487","last_page":"492"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12282","display_name":"Mineral Processing and Grinding","score":0.9470999836921692,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10640","display_name":"Spectroscopy and Chemometric Analyses","score":0.920199990272522,"subfield":{"id":"https://openalex.org/subfields/1602","display_name":"Analytical Chemistry"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7904053926467896},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6535787582397461},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.6137523651123047},{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.5890594720840454},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.534051775932312},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.5298033952713013},{"id":"https://openalex.org/keywords/transfer-function","display_name":"Transfer function","score":0.4476807713508606},{"id":"https://openalex.org/keywords/domain","display_name":"Domain (mathematical analysis)","score":0.415979266166687},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3972506523132324},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.395699143409729},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38932883739471436},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.24594271183013916},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.1764206886291504},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10476401448249817}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7904053926467896},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6535787582397461},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.6137523651123047},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.5890594720840454},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.534051775932312},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.5298033952713013},{"id":"https://openalex.org/C81299745","wikidata":"https://www.wikidata.org/wiki/Q334269","display_name":"Transfer function","level":2,"score":0.4476807713508606},{"id":"https://openalex.org/C36503486","wikidata":"https://www.wikidata.org/wiki/Q11235244","display_name":"Domain (mathematical analysis)","level":2,"score":0.415979266166687},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3972506523132324},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.395699143409729},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38932883739471436},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.24594271183013916},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.1764206886291504},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10476401448249817},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc.2001.7075954","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.2001.7075954","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2001 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W1965324089"],"related_works":["https://openalex.org/W2560215812","https://openalex.org/W2949601986","https://openalex.org/W2788972299","https://openalex.org/W2521347458","https://openalex.org/W2498789492","https://openalex.org/W4385301753","https://openalex.org/W3186428265","https://openalex.org/W2171501125","https://openalex.org/W2617234683","https://openalex.org/W2375947351"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"the":[3,20,23,46,58,62,70,85],"implementation":[4],"of":[5,22,48,84,109],"a":[6,49,79,93,110],"Model":[7],"Based":[8],"Fault":[9,128],"Detection":[10,80],"and":[11,90,118],"Diagnosis":[12,94],"System,":[13],"that":[14],"uses":[15],"fuzzy":[16],"logic":[17],"to":[18,96,116],"determinate":[19],"nature":[21],"detected":[24,98],"faults":[25],"in":[26,78,92,114],"rolling":[27],"mill":[28],"equipments":[29],"is":[30,34,75,103],"presented.":[31],"The":[32,82,101],"system":[33,102],"built":[35],"with":[36],"4":[37],"components":[38],"which":[39,74],"work":[40],"independently.":[41],"An":[42],"Identification":[43],"module":[44,68,95],"estimates":[45],"parameters":[47],"continuous":[50],"domain":[51],"second":[52],"order":[53,115],"transfer":[54],"function":[55],"model":[56,67],"for":[57],"process":[59,113],"by":[60],"analyzing":[61],"step":[63],"response.":[64],"A":[65],"Predictive":[66],"generates":[69],"controlled":[71],"variable":[72],"residual":[73],"statistically":[76],"analyzed":[77],"module.":[81],"results":[83],"statistical":[86],"analysis":[87],"are":[88],"fuzzified":[89],"processed":[91],"determine":[97],"fault's":[99],"nature.":[100],"tested":[104],"using":[105],"real":[106],"operation":[107],"data":[108],"main":[111],"motor":[112],"detect":[117],"classify":[119],"abnormalities":[120],"into":[121],"Operation":[122],"Point":[123],"Change":[124],"(OPC)":[125],"or":[126],"Process":[127],"(PF)":[129],"alarms.":[130]},"counts_by_year":[{"year":2012,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
