{"id":"https://openalex.org/W1508300275","doi":"https://doi.org/10.23919/ecc.1999.7099967","title":"Neural observer-based approach to fault-tolerant control of a three-tank system","display_name":"Neural observer-based approach to fault-tolerant control of a three-tank system","publication_year":1999,"publication_date":"1999-08-01","ids":{"openalex":"https://openalex.org/W1508300275","doi":"https://doi.org/10.23919/ecc.1999.7099967","mag":"1508300275"},"language":"en","primary_location":{"id":"doi:10.23919/ecc.1999.7099967","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.1999.7099967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"1999 European Control Conference (ECC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029291186","display_name":"Teodor Marcu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"T. Marcu","raw_affiliation_strings":["Universitat Duisburg-Essen, Duisburg, Nordrhein-Westfalen, DE"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Duisburg-Essen, Duisburg, Nordrhein-Westfalen, DE","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047111551","display_name":"Mihaela-Hanako Matcovschi","orcid":"https://orcid.org/0000-0001-6141-2031"},"institutions":[{"id":"https://openalex.org/I4210158639","display_name":"National Institute of Research and Development for Technical Physics","ror":"https://ror.org/05dv4bz40","country_code":"RO","type":"facility","lineage":["https://openalex.org/I4210158639"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"M.H. Matcovschi","raw_affiliation_strings":["Technical University of Iasi, Department of Automatic Control, Blvd. D. Mangeron Nr. 53A, RO-6600 Iasi, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technical University of Iasi, Department of Automatic Control, Blvd. D. Mangeron Nr. 53A, RO-6600 Iasi, Romania","institution_ids":["https://openalex.org/I4210158639"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109248550","display_name":"P.M. Frank","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"P.M. Frank","raw_affiliation_strings":["Universitat Duisburg-Essen, Duisburg, Nordrhein-Westfalen, DE"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitat Duisburg-Essen, Duisburg, Nordrhein-Westfalen, DE","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.5506,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.95006624,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":95},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9889000058174133,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9832000136375427,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.8919245004653931},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.7587625980377197},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7414312958717346},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.639560878276825},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5977596640586853},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5819600820541382},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5523567199707031},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.5373806953430176},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5349335670471191},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5277538895606995},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.520604133605957},{"id":"https://openalex.org/keywords/set","display_name":"Set (abstract data type)","score":0.4662303924560547},{"id":"https://openalex.org/keywords/supervisory-control","display_name":"Supervisory control","score":0.4342150390148163},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.43237537145614624},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.41890281438827515},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4078027009963989},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3800632655620575},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.1473202109336853}],"concepts":[{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.8919245004653931},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.7587625980377197},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7414312958717346},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.639560878276825},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5977596640586853},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5819600820541382},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5523567199707031},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5373806953430176},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5349335670471191},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5277538895606995},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.520604133605957},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.4662303924560547},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.4342150390148163},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.43237537145614624},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.41890281438827515},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4078027009963989},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3800632655620575},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.1473202109336853},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/ecc.1999.7099967","is_oa":false,"landing_page_url":"https://doi.org/10.23919/ecc.1999.7099967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"1999 European Control Conference (ECC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.46000000834465027,"display_name":"Peace, Justice and strong institutions","id":"https://metadata.un.org/sdg/16"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W207455506","https://openalex.org/W1254918811","https://openalex.org/W1487888754","https://openalex.org/W1499664677","https://openalex.org/W2044085155","https://openalex.org/W2058832529","https://openalex.org/W2112465475","https://openalex.org/W2798567529"],"related_works":["https://openalex.org/W2357657342","https://openalex.org/W2153432761","https://openalex.org/W1580144672","https://openalex.org/W2152623100","https://openalex.org/W2142042635","https://openalex.org/W2130594209","https://openalex.org/W1950809481","https://openalex.org/W2085988155","https://openalex.org/W3121254296","https://openalex.org/W2060193301"],"abstract_inverted_index":{"The":[0,30,73,85],"simulated":[1],"laboratory":[2],"set-up":[3],"Three-Tank":[4],"System":[5],"is":[6,25,36,80],"investigated":[7],"from":[8],"the":[9,33,45,60,66,88,91],"standpoint":[10],"of":[11,32,51,77,87],"fault-tolerant":[12],"control.":[13],"Different":[14],"neural":[15,28,83],"observer":[16],"schemes":[17],"are":[18,63],"used":[19],"for":[20],"symptom":[21],"generation.":[22],"Symptom":[23],"evaluation":[24],"based":[26,64,81],"on":[27,44,65,82],"classifiers.":[29],"output":[31],"classification":[34],"stage":[35],"provided":[37],"to":[38],"a":[39,52],"supervisory":[40],"unit.":[41],"This":[42],"switches":[43],"appropriate":[46],"remedy":[47],"action":[48],"in":[49,75],"case":[50,76],"process":[53],"fault.":[54],"For":[55],"actuator":[56],"and":[57,69],"component":[58],"faults,":[59],"reconfiguration":[61,74],"strategies":[62],"redundant":[67],"hardware":[68],"optimised":[70],"control":[71],"laws.":[72],"sensor":[78],"faults":[79],"observers.":[84],"outputs":[86],"latter":[89],"replace":[90],"faulty":[92],"sensor(s).":[93]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
