{"id":"https://openalex.org/W4413394820","doi":"https://doi.org/10.23919/acc63710.2025.11107449","title":"Robust Control of an Inverting Buck-Boost Converter Under Exogenous Disturbances","display_name":"Robust Control of an Inverting Buck-Boost Converter Under Exogenous Disturbances","publication_year":2025,"publication_date":"2025-07-08","ids":{"openalex":"https://openalex.org/W4413394820","doi":"https://doi.org/10.23919/acc63710.2025.11107449"},"language":"en","primary_location":{"id":"doi:10.23919/acc63710.2025.11107449","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc63710.2025.11107449","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 American Control Conference (ACC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084499393","display_name":"Rodolfo Verd\u00edn","orcid":"https://orcid.org/0000-0003-1119-5395"},"institutions":[{"id":"https://openalex.org/I4210162390","display_name":"Universidad Filadelfia de M\u00e9xico","ror":"https://ror.org/053d5gs04","country_code":"MX","type":"education","lineage":["https://openalex.org/I4210162390"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"Rodolfo Verd\u00edn","raw_affiliation_strings":["Center for Research in Optics,Laboratorio de Percepci&#x00F3;n y Rob&#x00F3;tica,Le&#x00F3;n,Mexico,37150"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Research in Optics,Laboratorio de Percepci&#x00F3;n y Rob&#x00F3;tica,Le&#x00F3;n,Mexico,37150","institution_ids":["https://openalex.org/I4210162390"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057340544","display_name":"Gerardo Flores","orcid":"https://orcid.org/0000-0003-2107-7405"},"institutions":[{"id":"https://openalex.org/I131740757","display_name":"Texas A&M International University","ror":"https://ror.org/028861t28","country_code":"US","type":"education","lineage":["https://openalex.org/I131740757"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Gerardo Flores","raw_affiliation_strings":["Texas A&amp;M International University,RAPTOR Lab, School of Engineering, College of Arts and Sciences,Laredo,TX,USA,78041"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Texas A&amp;M International University,RAPTOR Lab, School of Engineering, College of Arts and Sciences,Laredo,TX,USA,78041","institution_ids":["https://openalex.org/I131740757"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5352,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.69669178,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"5034","last_page":"5039"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.973800003528595,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.973800003528595,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9383000135421753,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6433203220367432},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.6244369149208069},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.5120406746864319},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4820057451725006},{"id":"https://openalex.org/keywords/robust-control","display_name":"Robust control","score":0.48172619938850403},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.45656073093414307},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.3907521069049835},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.32012617588043213},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18371343612670898},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.13135558366775513},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.10554134845733643},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08873000741004944}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6433203220367432},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.6244369149208069},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5120406746864319},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4820057451725006},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.48172619938850403},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.45656073093414307},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.3907521069049835},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.32012617588043213},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18371343612670898},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.13135558366775513},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10554134845733643},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08873000741004944}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/acc63710.2025.11107449","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc63710.2025.11107449","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 American Control Conference (ACC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.800000011920929}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1551360398","https://openalex.org/W1973190177","https://openalex.org/W2080698269","https://openalex.org/W2099016058","https://openalex.org/W2103783575","https://openalex.org/W2121202838","https://openalex.org/W2171934072","https://openalex.org/W2324434657","https://openalex.org/W2593065393","https://openalex.org/W2897058198","https://openalex.org/W2984195585","https://openalex.org/W2999984502","https://openalex.org/W3086369747","https://openalex.org/W3091785768","https://openalex.org/W3112152360","https://openalex.org/W3123492637","https://openalex.org/W3158720987","https://openalex.org/W4205087059","https://openalex.org/W4220952010","https://openalex.org/W4225857809","https://openalex.org/W4293078920","https://openalex.org/W4313449765","https://openalex.org/W4380903907","https://openalex.org/W4387427231","https://openalex.org/W4402263764"],"related_works":["https://openalex.org/W2169705106","https://openalex.org/W2249417072","https://openalex.org/W2134431346","https://openalex.org/W4286633625","https://openalex.org/W4210485917","https://openalex.org/W2390522420","https://openalex.org/W3023706037","https://openalex.org/W1943439215","https://openalex.org/W2168219526","https://openalex.org/W2104535426"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,29,57,72,75],"design":[4],"and":[5,38,49,68,81],"implementation":[6],"of":[7,31,74],"a":[8,14,52],"robust":[9],"nonlinear":[10,53],"control":[11],"strategy":[12],"for":[13],"DC-DC":[15],"inverting":[16],"buck-boost":[17],"converter.":[18],"The":[19,59],"proposed":[20,76],"controller":[21,55],"ensures":[22],"finite-time":[23],"almost":[24],"global":[25],"stability,":[26,65],"even":[27],"in":[28,64,78],"presence":[30],"external":[32],"disturbances":[33],"such":[34],"as":[35],"voltage":[36],"fluctuations":[37],"noise.":[39],"To":[40],"evaluate":[41],"its":[42],"performance,":[43],"software-in-the-loop":[44],"(SITL)":[45],"simulations":[46],"were":[47],"conducted":[48],"compared":[50],"against":[51],"PI-type":[54],"from":[56],"literature.":[58],"results":[60],"demonstrate":[61],"significant":[62],"improvements":[63],"convergence":[66],"speed,":[67],"disturbance":[69],"rejection,":[70],"confirming":[71],"effectiveness":[73],"approach":[77],"handling":[79],"dynamic":[80],"uncertain":[82],"operating":[83],"conditions.":[84]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
