{"id":"https://openalex.org/W3046049909","doi":"https://doi.org/10.23919/acc45564.2020.9147490","title":"Fault Detection and Isolation for a Class of Uncertain Nonlinear Systems: A Switching Approach","display_name":"Fault Detection and Isolation for a Class of Uncertain Nonlinear Systems: A Switching Approach","publication_year":2020,"publication_date":"2020-07-01","ids":{"openalex":"https://openalex.org/W3046049909","doi":"https://doi.org/10.23919/acc45564.2020.9147490","mag":"3046049909"},"language":"en","primary_location":{"id":"doi:10.23919/acc45564.2020.9147490","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc45564.2020.9147490","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 American Control Conference (ACC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043862385","display_name":"Hupo Ouyang","orcid":"https://orcid.org/0000-0001-6983-9072"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Hupo Ouyang","raw_affiliation_strings":["School of Automation, Beihang University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069605605","display_name":"Yan Lin","orcid":"https://orcid.org/0000-0003-4419-9050"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yan Lin","raw_affiliation_strings":["School of Automation, Beihang University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101452101","display_name":"Fei Tao","orcid":"https://orcid.org/0000-0002-4602-2008"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fei Tao","raw_affiliation_strings":["School of Automation, Beihang University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"School of Automation, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5043862385"],"corresponding_institution_ids":["https://openalex.org/I82880672"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.08432338,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"3193","last_page":"3198"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14470","display_name":"Advanced Data Processing Techniques","score":0.9908000230789185,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7958247661590576},{"id":"https://openalex.org/keywords/control-reconfiguration","display_name":"Control reconfiguration","score":0.7005777955055237},{"id":"https://openalex.org/keywords/backstepping","display_name":"Backstepping","score":0.690915584564209},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.663846492767334},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.60749351978302},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5577876567840576},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5223152041435242},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.47362110018730164},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.45785534381866455},{"id":"https://openalex.org/keywords/supervisory-control","display_name":"Supervisory control","score":0.4379868805408478},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.39475566148757935},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2631914019584656},{"id":"https://openalex.org/keywords/adaptive-control","display_name":"Adaptive control","score":0.21217384934425354},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.19808006286621094},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1484799087047577},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.08019039034843445}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7958247661590576},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.7005777955055237},{"id":"https://openalex.org/C72218879","wikidata":"https://www.wikidata.org/wiki/Q4839759","display_name":"Backstepping","level":4,"score":0.690915584564209},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.663846492767334},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.60749351978302},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5577876567840576},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5223152041435242},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.47362110018730164},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.45785534381866455},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.4379868805408478},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39475566148757935},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2631914019584656},{"id":"https://openalex.org/C107464732","wikidata":"https://www.wikidata.org/wiki/Q235781","display_name":"Adaptive control","level":3,"score":0.21217384934425354},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.19808006286621094},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1484799087047577},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.08019039034843445},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/acc45564.2020.9147490","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc45564.2020.9147490","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 American Control Conference (ACC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1976471875","https://openalex.org/W2037113551","https://openalex.org/W2083514989","https://openalex.org/W2090167557","https://openalex.org/W2102832680","https://openalex.org/W2113508851","https://openalex.org/W2127801773","https://openalex.org/W2163573608","https://openalex.org/W2172678131","https://openalex.org/W2607297160","https://openalex.org/W2778985631","https://openalex.org/W2964241344"],"related_works":["https://openalex.org/W2771027241","https://openalex.org/W1765905465","https://openalex.org/W2793080664","https://openalex.org/W2186140227","https://openalex.org/W2534185822","https://openalex.org/W2132535444","https://openalex.org/W2367651125","https://openalex.org/W2387936656","https://openalex.org/W2063297487","https://openalex.org/W2567073787"],"abstract_inverted_index":{"A":[0],"fault":[1,28,67,72],"detection":[2],"and":[3,20,30,68],"isolation":[4,29],"(FDI)":[5],"scheme":[6],"is":[7,26,75,102],"proposed":[8],"for":[9],"a":[10,36,42,85,95],"class":[11],"of":[12,44,66,89,94,109],"nonlinear":[13],"systems":[14],"with":[15],"unknown":[16],"faults,":[17],"system":[18,90,97],"uncertainties":[19],"external":[21],"disturbances.":[22],"The":[23],"main":[24],"feature":[25],"that":[27,77],"control":[31],"reconfiguration":[32],"are":[33,60],"integrated":[34],"via":[35],"supervisory":[37],"switching":[38],"strategy.":[39],"By":[40],"constructing":[41],"set":[43],"monitoring":[45],"functions":[46],"(MFs)":[47],"to":[48,62,99,105],"supervise":[49],"some":[50],"variables":[51],"generated":[52],"in":[53],"the":[54,57,64,70,78,107],"backstepping":[55],"procedure,":[56],"candidate":[58],"controllers":[59],"switched":[61],"detect":[63],"occurrence":[65],"identify":[69],"specific":[71],"type.":[73],"It":[74],"shown":[76],"tracking":[79],"error":[80],"can":[81],"be":[82],"preserved":[83],"within":[84],"prescribed":[86],"performance":[87],"regardless":[88],"faults.":[91],"Case":[92],"study":[93],"manipulator":[96],"subject":[98],"different":[100],"faults":[101],"carried":[103],"out":[104],"validate":[106],"effectiveness":[108],"this":[110],"FDI":[111],"approach.":[112]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
