{"id":"https://openalex.org/W2735240926","doi":"https://doi.org/10.23919/acc.2017.7963470","title":"Primary frequency response with aggregated DERs","display_name":"Primary frequency response with aggregated DERs","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2735240926","doi":"https://doi.org/10.23919/acc.2017.7963470","mag":"2735240926"},"language":"en","primary_location":{"id":"doi:10.23919/acc.2017.7963470","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc.2017.7963470","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 American Control Conference (ACC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050609852","display_name":"Swaroop S. Guggilam","orcid":"https://orcid.org/0000-0002-5016-7015"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Swaroop S. Guggilam","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA","institution_ids":["https://openalex.org/I130238516"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015970180","display_name":"Changhong Zhao","orcid":"https://orcid.org/0000-0003-0539-8591"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Changhong Zhao","raw_affiliation_strings":["National Renewable Energy Laboratory, Golden, CO"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Renewable Energy Laboratory, Golden, CO","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060100126","display_name":"Emiliano Dall\u2019Anese","orcid":"https://orcid.org/0000-0002-6486-7477"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Emiliano Dall'Anese","raw_affiliation_strings":["National Renewable Energy Laboratory, Golden, CO, US"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Renewable Energy Laboratory, Golden, CO, US","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055972810","display_name":"Yu Christine Chen","orcid":"https://orcid.org/0000-0002-6101-4989"},"institutions":[{"id":"https://openalex.org/I141945490","display_name":"University of British Columbia","ror":"https://ror.org/03rmrcq20","country_code":"CA","type":"education","lineage":["https://openalex.org/I141945490"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Yu Christine Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, British Columbia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, British Columbia","institution_ids":["https://openalex.org/I141945490"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5081876985","display_name":"Sairaj V. Dhople","orcid":"https://orcid.org/0000-0002-1180-1415"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Sairaj V. Dhople","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA","institution_ids":["https://openalex.org/I130238516"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.8368,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.86038719,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"3386","last_page":"3393"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.8075519800186157},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.6547375917434692},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.6473934054374695},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5984563827514648},{"id":"https://openalex.org/keywords/governor","display_name":"Governor","score":0.5808111429214478},{"id":"https://openalex.org/keywords/frequency-domain","display_name":"Frequency domain","score":0.5272494554519653},{"id":"https://openalex.org/keywords/frequency-response","display_name":"Frequency response","score":0.4477809965610504},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.4410945773124695},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.42351648211479187},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.397093802690506},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2911641001701355},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2185007929801941},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2032909393310547},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.18461200594902039},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.18136826157569885},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.17353081703186035}],"concepts":[{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.8075519800186157},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.6547375917434692},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6473934054374695},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5984563827514648},{"id":"https://openalex.org/C2781233147","wikidata":"https://www.wikidata.org/wiki/Q3229617","display_name":"Governor","level":2,"score":0.5808111429214478},{"id":"https://openalex.org/C19118579","wikidata":"https://www.wikidata.org/wiki/Q786423","display_name":"Frequency domain","level":2,"score":0.5272494554519653},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.4477809965610504},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4410945773124695},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42351648211479187},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.397093802690506},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2911641001701355},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2185007929801941},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2032909393310547},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18461200594902039},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.18136826157569885},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.17353081703186035},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/acc.2017.7963470","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc.2017.7963470","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 American Control Conference (ACC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8700000047683716,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W295802","https://openalex.org/W1481640635","https://openalex.org/W1541786028","https://openalex.org/W1971119884","https://openalex.org/W1980227625","https://openalex.org/W2019090179","https://openalex.org/W2027037246","https://openalex.org/W2048525568","https://openalex.org/W2055611995","https://openalex.org/W2082662944","https://openalex.org/W2103762106","https://openalex.org/W2116525489","https://openalex.org/W2122032342","https://openalex.org/W2164961065","https://openalex.org/W2321414982","https://openalex.org/W2338299843","https://openalex.org/W2388907722","https://openalex.org/W2734857094","https://openalex.org/W2954348634","https://openalex.org/W2963389126","https://openalex.org/W6600014438","https://openalex.org/W6645243218"],"related_works":["https://openalex.org/W2903648507","https://openalex.org/W2529755282","https://openalex.org/W3095853931","https://openalex.org/W4379525856","https://openalex.org/W4213134919","https://openalex.org/W2766311747","https://openalex.org/W4231913803","https://openalex.org/W2751689184","https://openalex.org/W2283881681","https://openalex.org/W4321844062"],"abstract_inverted_index":{"Power":[0],"networks":[1,63],"have":[2],"to":[3,64,110,147],"withstand":[4],"a":[5,27,53,89,111,135],"variety":[6],"of":[7,22,106,134],"disturbances":[8],"that":[9,84,104,115],"affect":[10],"system":[11,33],"frequency,":[12],"and":[13,139],"the":[14,19,85,94,98,124,149],"problem":[15],"is":[16,35],"compounded":[17],"with":[18,142],"increasing":[20],"integration":[21],"intermittent":[23],"renewable":[24],"generation.":[25],"Following":[26],"large-signal":[28],"generation":[29],"or":[30],"load":[31],"disturbance,":[32],"frequency":[34,39,68],"arrested":[36],"leveraging":[37],"primary":[38,67],"control":[40],"provided":[41,146],"by":[42],"governor":[43],"action":[44],"in":[45,61],"synchronous":[46],"generators.":[47],"In":[48],"this":[49],"work,":[50],"we":[51,71],"propose":[52],"framework":[54],"for":[55,77,120,129],"distributed":[56],"energy":[57],"resources":[58],"(DERs)":[59],"deployed":[60],"distribution":[62,86,125,140],"provide":[65],"(supplemental)":[66],"response.":[69],"Particularly,":[70],"demonstrate":[72],"how":[73],"power-frequency":[74],"droop":[75,99],"slopes":[76,100],"individual":[78,107],"DERs":[79,108,144],"can":[80],"be":[81],"designed":[82],"so":[83],"feeder":[87,95],"presents":[88],"guaranteed":[90],"frequency-regulation":[91],"characteristic":[92],"at":[93],"head.":[96],"Furthermore,":[97],"are":[101,145],"engineered":[102],"such":[103],"injections":[105],"conform":[109],"well-defined":[112],"fairness":[113],"objective":[114],"does":[116],"not":[117],"penalize":[118],"them":[119],"their":[121],"location":[122],"on":[123],"feeder.":[126],"Time-domain":[127],"simulations":[128],"an":[130],"illustrative":[131],"network":[132,138,141],"composed":[133],"combined":[136],"transmission":[137],"frequency-responsive":[143],"validate":[148],"approach.":[150]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":4},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":4}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2017-07-21T00:00:00"}
