{"id":"https://openalex.org/W2736101401","doi":"https://doi.org/10.23919/acc.2017.7963154","title":"Packetized energy management: Asynchronous and anonymous coordination of thermostatically controlled loads","display_name":"Packetized energy management: Asynchronous and anonymous coordination of thermostatically controlled loads","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2736101401","doi":"https://doi.org/10.23919/acc.2017.7963154","mag":"2736101401"},"language":"en","primary_location":{"id":"doi:10.23919/acc.2017.7963154","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc.2017.7963154","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 American Control Conference (ACC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053327116","display_name":"Mads Almassalkhi","orcid":"https://orcid.org/0000-0003-3536-5563"},"institutions":[{"id":"https://openalex.org/I111236770","display_name":"University of Vermont","ror":"https://ror.org/0155zta11","country_code":"US","type":"education","lineage":["https://openalex.org/I111236770"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Mads Almassalkhi","raw_affiliation_strings":["Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A","institution_ids":["https://openalex.org/I111236770"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067954811","display_name":"Jeff Frol\u00edk","orcid":"https://orcid.org/0000-0002-4006-9163"},"institutions":[{"id":"https://openalex.org/I111236770","display_name":"University of Vermont","ror":"https://ror.org/0155zta11","country_code":"US","type":"education","lineage":["https://openalex.org/I111236770"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jeff Frolik","raw_affiliation_strings":["Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A","institution_ids":["https://openalex.org/I111236770"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5065579564","display_name":"Paul Hines","orcid":"https://orcid.org/0000-0002-6553-7103"},"institutions":[{"id":"https://openalex.org/I111236770","display_name":"University of Vermont","ror":"https://ror.org/0155zta11","country_code":"US","type":"education","lineage":["https://openalex.org/I111236770"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Paul Hines","raw_affiliation_strings":["Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT, U.S.A","institution_ids":["https://openalex.org/I111236770"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5053327116"],"corresponding_institution_ids":["https://openalex.org/I111236770"],"apc_list":null,"apc_paid":null,"fwci":3.6332,"has_fulltext":false,"cited_by_count":42,"citation_normalized_percentile":{"value":0.93537406,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1431","last_page":"1437"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9908999800682068,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9894999861717224,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5960926413536072},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.595281183719635},{"id":"https://openalex.org/keywords/asynchronous-communication","display_name":"Asynchronous communication","score":0.5761831402778625},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.5472407937049866},{"id":"https://openalex.org/keywords/probabilistic-logic","display_name":"Probabilistic logic","score":0.48981973528862},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.48568567633628845},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4710994362831116},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.4655047059059143},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.45923882722854614},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3814038336277008},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.32625842094421387},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.280134379863739},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24736157059669495},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10739505290985107}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5960926413536072},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.595281183719635},{"id":"https://openalex.org/C151319957","wikidata":"https://www.wikidata.org/wiki/Q752739","display_name":"Asynchronous communication","level":2,"score":0.5761831402778625},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.5472407937049866},{"id":"https://openalex.org/C49937458","wikidata":"https://www.wikidata.org/wiki/Q2599292","display_name":"Probabilistic logic","level":2,"score":0.48981973528862},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.48568567633628845},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4710994362831116},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.4655047059059143},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.45923882722854614},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3814038336277008},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.32625842094421387},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.280134379863739},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24736157059669495},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10739505290985107},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.23919/acc.2017.7963154","is_oa":false,"landing_page_url":"https://doi.org/10.23919/acc.2017.7963154","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 American Control Conference (ACC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1719735919","https://openalex.org/W1965922214","https://openalex.org/W1968658010","https://openalex.org/W1976698613","https://openalex.org/W2000095956","https://openalex.org/W2005585337","https://openalex.org/W2009022268","https://openalex.org/W2063135086","https://openalex.org/W2066381546","https://openalex.org/W2069056190","https://openalex.org/W2093313974","https://openalex.org/W2110923414","https://openalex.org/W2174209625","https://openalex.org/W2180199879","https://openalex.org/W2197256916","https://openalex.org/W2306601353","https://openalex.org/W2613835202","https://openalex.org/W3100027482","https://openalex.org/W3105469850"],"related_works":["https://openalex.org/W2171108821","https://openalex.org/W2353074559","https://openalex.org/W2074513827","https://openalex.org/W2402141875","https://openalex.org/W1498762745","https://openalex.org/W1589973774","https://openalex.org/W148990555","https://openalex.org/W2023642087","https://openalex.org/W2392147676","https://openalex.org/W2035833777"],"abstract_inverted_index":{"Because":[0],"of":[1,36,39,55,76,85,114],"their":[2,22],"internal":[3],"energy":[4,98],"storage,":[5],"electrically":[6],"powered,":[7],"distributed":[8],"thermostatically":[9],"controlled":[10],"loads":[11],"(TCLs)":[12],"have":[13],"the":[14,26,74,77,108,122,134,147],"potential":[15],"to":[16,20,25,32,44,68,97],"be":[17,45],"dynamically":[18],"managed":[19,46],"match":[21],"aggregate":[23,148],"load":[24,40],"available":[27],"supply.":[28],"However,":[29],"in":[30,47],"order":[31],"facilitate":[33],"consumer":[34],"acceptance":[35],"this":[37],"type":[38],"management,":[41],"TCLs":[42,70],"need":[43],"a":[48,64,86,93,112,127,142],"way":[49],"that":[50,71,100,121,153],"avoids":[51],"degrading":[52,133],"perceived":[53],"quality":[54],"service":[56],"(QoS),":[57],"autonomy,":[58],"and":[59,79,119],"privacy.":[60],"This":[61],"paper":[62],"presents":[63],"real-time,":[65],"adaptable":[66],"approach":[67,96,110],"managing":[69],"both":[72],"meets":[73],"requirements":[75],"grid":[78],"does":[80],"not":[81],"require":[82],"explicit":[83],"knowledge":[84],"specific":[87],"TCL's":[88],"state.":[89],"The":[90],"method":[91,123],"leverages":[92],"packetized,":[94],"probabilistic":[95],"delivery":[99],"draws":[101],"inspiration":[102],"from":[103],"digital":[104],"communications.":[105],"We":[106],"demonstrate":[107],"packetized":[109],"using":[111],"case-study":[113],"1000":[115],"simulated":[116],"water":[117],"heaters":[118],"show":[120],"can":[124],"closely":[125],"track":[126],"time-varying":[128],"reference":[129],"signal":[130],"without":[131],"noticeably":[132],"QoS.":[135],"In":[136],"addition,":[137],"we":[138],"illustrate":[139],"how":[140],"placing":[141],"simple":[143],"ramp-rate":[144],"limit":[145],"on":[146],"response":[149],"overcomes":[150],"synchronization":[151],"effects":[152],"arise":[154],"under":[155],"prolonged":[156],"peak":[157],"curtailment":[158],"scenarios.":[159]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":11},{"year":2019,"cited_by_count":8},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2}],"updated_date":"2026-03-06T13:50:29.536080","created_date":"2025-10-10T00:00:00"}
